F. Goodarzi, K. Palaniappan, M. Pillay, Mahmoud Ershadi
{"title":"翻新建筑物室内空气质素评估的范围检讨","authors":"F. Goodarzi, K. Palaniappan, M. Pillay, Mahmoud Ershadi","doi":"10.1108/sasbe-12-2022-0264","DOIUrl":null,"url":null,"abstract":"PurposeExposure to poor indoor air in refurbished buildings is a matter of health concern due to the growing concentrations of various contaminants as a result of building airtightness without amendment of ventilation, or the use of building materials such as glue, paint, thinner and varnishes. Recent studies have been conducted to measure indoor air pollutants and assess the health risks affecting the quality of life, productivity and well-being of human beings. However, limited review studies have been recently conducted to provide an overview of the state of knowledge. This study aims to conduct a scoping review of indoor air quality (IAQ) in the context of refurbished or energy-retrofitted buildings.Design/methodology/approachA systematic screening process based on the PRISMA protocol was followed to extract relevant articles. Web of Science, Scopus, Google Scholar and PubMed were searched using customised search formulas. Among 276 potentially relevant records, 38 studies were included in the final review covering a period from 2015 to 2022.FindingsResearchers mapped out the measured compounds in the selected studies and found that carbon dioxide (CO2) (11%) and total volatile organic compounds (11%) were among the most commonly measured contaminants. Two trends of research were found including (1) the impact of ventilative properties on IAQ and (2) the impact of introducing building materials on IAQ.Originality/valueThe contribution of this study lies in summarising evidence on IAQ measurements in refurbished buildings, discussing recent advancements, revealing significant gaps and limitations, identifying the trends of research and drawing conclusions regarding future research directions on the topic.","PeriodicalId":45779,"journal":{"name":"Smart and Sustainable Built Environment","volume":"1 1","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2023-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A scoping review of indoor air quality assessment in refurbished buildings\",\"authors\":\"F. Goodarzi, K. Palaniappan, M. Pillay, Mahmoud Ershadi\",\"doi\":\"10.1108/sasbe-12-2022-0264\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PurposeExposure to poor indoor air in refurbished buildings is a matter of health concern due to the growing concentrations of various contaminants as a result of building airtightness without amendment of ventilation, or the use of building materials such as glue, paint, thinner and varnishes. Recent studies have been conducted to measure indoor air pollutants and assess the health risks affecting the quality of life, productivity and well-being of human beings. However, limited review studies have been recently conducted to provide an overview of the state of knowledge. This study aims to conduct a scoping review of indoor air quality (IAQ) in the context of refurbished or energy-retrofitted buildings.Design/methodology/approachA systematic screening process based on the PRISMA protocol was followed to extract relevant articles. Web of Science, Scopus, Google Scholar and PubMed were searched using customised search formulas. Among 276 potentially relevant records, 38 studies were included in the final review covering a period from 2015 to 2022.FindingsResearchers mapped out the measured compounds in the selected studies and found that carbon dioxide (CO2) (11%) and total volatile organic compounds (11%) were among the most commonly measured contaminants. Two trends of research were found including (1) the impact of ventilative properties on IAQ and (2) the impact of introducing building materials on IAQ.Originality/valueThe contribution of this study lies in summarising evidence on IAQ measurements in refurbished buildings, discussing recent advancements, revealing significant gaps and limitations, identifying the trends of research and drawing conclusions regarding future research directions on the topic.\",\"PeriodicalId\":45779,\"journal\":{\"name\":\"Smart and Sustainable Built Environment\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2023-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Smart and Sustainable Built Environment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1108/sasbe-12-2022-0264\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"GREEN & SUSTAINABLE SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Smart and Sustainable Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/sasbe-12-2022-0264","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GREEN & SUSTAINABLE SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 1
摘要
目的:由于建筑物不通风,或使用胶水、油漆、稀释剂和清漆等建筑材料,使各种污染物的浓度不断增加,因此,在翻新的建筑物中接触不良的室内空气是一个健康问题。最近进行了一些研究,以测量室内空气污染物并评估影响人类生活质量、生产力和福祉的健康风险。然而,最近进行了有限的审查研究,以提供对知识状况的概述。本研究旨在进行室内空气质量(IAQ)的范围审查在翻新或能源改造的建筑物的背景下。设计/方法学/方法采用基于PRISMA方案的系统筛选流程,提取相关文章。使用定制的搜索公式对Web of Science、Scopus、b谷歌Scholar和PubMed进行了搜索。在276项可能相关的记录中,有38项研究被纳入了最终审查,时间跨度从2015年到2022年。研究人员在选定的研究中绘制了测量的化合物,发现二氧化碳(CO2)(11%)和总挥发性有机化合物(11%)是最常测量的污染物。研究发现了两个研究趋势:(1)通风性能对室内空气质量的影响;(2)引入建筑材料对室内空气质量的影响。原创性/价值本研究的贡献在于总结了翻新建筑室内空气质量测量的证据,讨论了最近的进展,揭示了重大的差距和局限性,确定了研究的趋势,并就该主题的未来研究方向得出结论。
A scoping review of indoor air quality assessment in refurbished buildings
PurposeExposure to poor indoor air in refurbished buildings is a matter of health concern due to the growing concentrations of various contaminants as a result of building airtightness without amendment of ventilation, or the use of building materials such as glue, paint, thinner and varnishes. Recent studies have been conducted to measure indoor air pollutants and assess the health risks affecting the quality of life, productivity and well-being of human beings. However, limited review studies have been recently conducted to provide an overview of the state of knowledge. This study aims to conduct a scoping review of indoor air quality (IAQ) in the context of refurbished or energy-retrofitted buildings.Design/methodology/approachA systematic screening process based on the PRISMA protocol was followed to extract relevant articles. Web of Science, Scopus, Google Scholar and PubMed were searched using customised search formulas. Among 276 potentially relevant records, 38 studies were included in the final review covering a period from 2015 to 2022.FindingsResearchers mapped out the measured compounds in the selected studies and found that carbon dioxide (CO2) (11%) and total volatile organic compounds (11%) were among the most commonly measured contaminants. Two trends of research were found including (1) the impact of ventilative properties on IAQ and (2) the impact of introducing building materials on IAQ.Originality/valueThe contribution of this study lies in summarising evidence on IAQ measurements in refurbished buildings, discussing recent advancements, revealing significant gaps and limitations, identifying the trends of research and drawing conclusions regarding future research directions on the topic.