从测量到可持续选择[观点]

M. Srivastava
{"title":"从测量到可持续选择[观点]","authors":"M. Srivastava","doi":"10.1109/MDT.2012.2202565","DOIUrl":null,"url":null,"abstract":"For measurement of energy consumption to be truly useful for sustainability measures, the measurement of energy consumption in a building must be real-time, frequent, holistic, and most importantly disaggregated. Holistic implies that measurements must encompass all forms of energy use, both direct (electricity and natural gas) and indirect (water embedded energy), and being disaggregated requires that energy use must be at the level of devices and appliances as opposed for the whole building. Conventional solutions to measuring disaggregated end use of electricity and water require deploying at each end-point precalibrated in-line mesh networked sensors for measuring voltage/current, water flow rate, etc. Besides being costly, such “direct sensors”are aesthetically intrusive, and often need costly professional installation and impose network management burden.","PeriodicalId":50392,"journal":{"name":"IEEE Design & Test of Computers","volume":"29 1","pages":"58-60"},"PeriodicalIF":0.0000,"publicationDate":"2012-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/MDT.2012.2202565","citationCount":"1","resultStr":"{\"title\":\"From measurements to sustainable choices [Persepectives]\",\"authors\":\"M. Srivastava\",\"doi\":\"10.1109/MDT.2012.2202565\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For measurement of energy consumption to be truly useful for sustainability measures, the measurement of energy consumption in a building must be real-time, frequent, holistic, and most importantly disaggregated. Holistic implies that measurements must encompass all forms of energy use, both direct (electricity and natural gas) and indirect (water embedded energy), and being disaggregated requires that energy use must be at the level of devices and appliances as opposed for the whole building. Conventional solutions to measuring disaggregated end use of electricity and water require deploying at each end-point precalibrated in-line mesh networked sensors for measuring voltage/current, water flow rate, etc. Besides being costly, such “direct sensors”are aesthetically intrusive, and often need costly professional installation and impose network management burden.\",\"PeriodicalId\":50392,\"journal\":{\"name\":\"IEEE Design & Test of Computers\",\"volume\":\"29 1\",\"pages\":\"58-60\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/MDT.2012.2202565\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Design & Test of Computers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MDT.2012.2202565\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Design & Test of Computers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MDT.2012.2202565","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

为了使能源消耗的测量对可持续发展措施真正有用,建筑物的能源消耗测量必须是实时的、频繁的、整体的,最重要的是分类的。整体意味着测量必须包含所有形式的能源使用,包括直接(电力和天然气)和间接(水嵌入能源),而分解要求能源使用必须在设备和电器的水平上,而不是整个建筑物。测量电力和水的分解终端使用的传统解决方案需要在每个终端部署预校准的在线网状网络传感器,用于测量电压/电流,水流速率等。除了价格昂贵之外,这种“直接传感器”在美观上具有干扰性,并且通常需要昂贵的专业安装和网络管理负担。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
From measurements to sustainable choices [Persepectives]
For measurement of energy consumption to be truly useful for sustainability measures, the measurement of energy consumption in a building must be real-time, frequent, holistic, and most importantly disaggregated. Holistic implies that measurements must encompass all forms of energy use, both direct (electricity and natural gas) and indirect (water embedded energy), and being disaggregated requires that energy use must be at the level of devices and appliances as opposed for the whole building. Conventional solutions to measuring disaggregated end use of electricity and water require deploying at each end-point precalibrated in-line mesh networked sensors for measuring voltage/current, water flow rate, etc. Besides being costly, such “direct sensors”are aesthetically intrusive, and often need costly professional installation and impose network management burden.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Design & Test of Computers
IEEE Design & Test of Computers 工程技术-工程:电子与电气
自引率
0.00%
发文量
1
审稿时长
>12 weeks
期刊最新文献
Message From the Steering Committee Conference reports Conference Reports Conference Reports Editorial Calendar
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1