{"title":"金属衬套单搭接沉头复合材料接头的拉伸性能","authors":"Xiaoquan Cheng, Xiaoyuan Du, Kun Chen, Maosheng Shu, Xiaodong Liu, Gang Chen","doi":"10.12989/SCS.2021.40.3.421","DOIUrl":null,"url":null,"abstract":"Tensile tests were carried out on the single-lap countersunk composite joints with metallic bushing, and the load-displacement curves, strains and damage morphologies around the bolt hole were measured. A 3D progressive damage finite element model (FEM) was established in ABAQUS/Standard and verified by experimental results. Based on the validated model, tensile performances of the joints were investigated, including damage mechanism analysis of the laminate and the effect discussion of bushing thickness, tightening torque, interference fit size and etc. The results show that metallic bushing can improve ultimate bearing load of the joints. The stress distribution and initial damages caused by assembly around the laminate hole are little affected by bushing thickness. Appropriate tightening torque and interference fit size can improve tensile performances of the joint.","PeriodicalId":51177,"journal":{"name":"Steel and Composite Structures","volume":"40 1","pages":"421"},"PeriodicalIF":4.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tensile performances of single-lap countersunk composite joints with metallic bushing\",\"authors\":\"Xiaoquan Cheng, Xiaoyuan Du, Kun Chen, Maosheng Shu, Xiaodong Liu, Gang Chen\",\"doi\":\"10.12989/SCS.2021.40.3.421\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Tensile tests were carried out on the single-lap countersunk composite joints with metallic bushing, and the load-displacement curves, strains and damage morphologies around the bolt hole were measured. A 3D progressive damage finite element model (FEM) was established in ABAQUS/Standard and verified by experimental results. Based on the validated model, tensile performances of the joints were investigated, including damage mechanism analysis of the laminate and the effect discussion of bushing thickness, tightening torque, interference fit size and etc. The results show that metallic bushing can improve ultimate bearing load of the joints. The stress distribution and initial damages caused by assembly around the laminate hole are little affected by bushing thickness. Appropriate tightening torque and interference fit size can improve tensile performances of the joint.\",\"PeriodicalId\":51177,\"journal\":{\"name\":\"Steel and Composite Structures\",\"volume\":\"40 1\",\"pages\":\"421\"},\"PeriodicalIF\":4.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Steel and Composite Structures\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.12989/SCS.2021.40.3.421\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Steel and Composite Structures","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.12989/SCS.2021.40.3.421","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Tensile performances of single-lap countersunk composite joints with metallic bushing
Tensile tests were carried out on the single-lap countersunk composite joints with metallic bushing, and the load-displacement curves, strains and damage morphologies around the bolt hole were measured. A 3D progressive damage finite element model (FEM) was established in ABAQUS/Standard and verified by experimental results. Based on the validated model, tensile performances of the joints were investigated, including damage mechanism analysis of the laminate and the effect discussion of bushing thickness, tightening torque, interference fit size and etc. The results show that metallic bushing can improve ultimate bearing load of the joints. The stress distribution and initial damages caused by assembly around the laminate hole are little affected by bushing thickness. Appropriate tightening torque and interference fit size can improve tensile performances of the joint.
期刊介绍:
Steel & Composite Structures, An International Journal, provides and excellent publication channel which reports the up-to-date research developments in the steel structures and steel-concrete composite structures, and FRP plated structures from the international steel community. The research results reported in this journal address all the aspects of theoretical and experimental research, including Buckling/Stability, Fatigue/Fracture, Fire Performance, Connections, Frames/Bridges, Plates/Shells, Composite Structural Components, Hybrid Structures, Fabrication/Maintenance, Design Codes, Dynamics/Vibrations, Nonferrous Metal Structures, Non-metalic plates, Analytical Methods.
The Journal specially wishes to bridge the gap between the theoretical developments and practical applications for the benefits of both academic researchers and practicing engineers. In this light, contributions from the practicing engineers are especially welcome.