{"title":"超声振幅对碳钢在3.5% NaCl溶液中空化过程中电化学性能的影响","authors":"I. J. Jang, Ki Tae Kim, Y. Yoo, Young-Sik Kim","doi":"10.14773/CST.2020.19.4.163","DOIUrl":null,"url":null,"abstract":"Cavitation corrosion in many industrial plants has recently become a serious issue. Cavitation corrosion has generally been investigated using a vibratory method based on ASTM G32 standard, and the test can be divided into direct cavitation and indirect cavitation. Cavitation corrosion test uses the vibration frequency of the horn of 20 kHz with constant peak-to-peak displacement amplitude. In this work, the peak-to-peak amplitude was controlled from 15 μm to 85 μm, and electrochemical measurements were obtained during indirect cavitation. The relationship between cavitation corrosion rate and electrochemical properties was discussed. Corrosion steps of carbon steel at the initial stage under cavitation condition in 3.5 % NaCl can be proposed. When the cavitation strength is relatively low, corrosion of the steel is more affected by the electrochemical process than by the mechanical process; but when the cavitation strength is relatively high, corrosion of the steel is affected more by the mechanical process than by the electrochemical process. This work confirmed that the critical ultrasonic amplitude of 0.42 %C carbon steel is 53.8 μm, and when the amplitude is less than 53.8 μm, the corrosion effect during the cavitation corrosion process is higher than the mechanical effect.","PeriodicalId":43201,"journal":{"name":"Corrosion Science and Technology-Korea","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Effects of Ultrasonic Amplitude on Electrochemical Properties During Cavitation of Carbon Steel in 3.5% NaCl Solution\",\"authors\":\"I. J. Jang, Ki Tae Kim, Y. Yoo, Young-Sik Kim\",\"doi\":\"10.14773/CST.2020.19.4.163\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cavitation corrosion in many industrial plants has recently become a serious issue. Cavitation corrosion has generally been investigated using a vibratory method based on ASTM G32 standard, and the test can be divided into direct cavitation and indirect cavitation. Cavitation corrosion test uses the vibration frequency of the horn of 20 kHz with constant peak-to-peak displacement amplitude. In this work, the peak-to-peak amplitude was controlled from 15 μm to 85 μm, and electrochemical measurements were obtained during indirect cavitation. The relationship between cavitation corrosion rate and electrochemical properties was discussed. Corrosion steps of carbon steel at the initial stage under cavitation condition in 3.5 % NaCl can be proposed. When the cavitation strength is relatively low, corrosion of the steel is more affected by the electrochemical process than by the mechanical process; but when the cavitation strength is relatively high, corrosion of the steel is affected more by the mechanical process than by the electrochemical process. This work confirmed that the critical ultrasonic amplitude of 0.42 %C carbon steel is 53.8 μm, and when the amplitude is less than 53.8 μm, the corrosion effect during the cavitation corrosion process is higher than the mechanical effect.\",\"PeriodicalId\":43201,\"journal\":{\"name\":\"Corrosion Science and Technology-Korea\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Corrosion Science and Technology-Korea\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14773/CST.2020.19.4.163\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Corrosion Science and Technology-Korea","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14773/CST.2020.19.4.163","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 2

摘要

近年来,在许多工业装置中,空化腐蚀已成为一个严重的问题。空化腐蚀的研究一般采用基于ASTM G32标准的振动法,试验可分为直接空化和间接空化。空化腐蚀试验采用恒峰间位移振幅的喇叭振动频率为20khz。在间接空化过程中,将峰间振幅控制在15 μm ~ 85 μm之间,进行了电化学测量。讨论了空化腐蚀速率与电化学性能的关系。提出了在3.5% NaCl中空化条件下碳钢初始阶段的腐蚀步骤。当空化强度较低时,电化学过程对钢的腐蚀影响大于机械过程;但当空化强度较高时,钢的腐蚀受机械过程的影响大于电化学过程的影响。本工作证实了0.42% C碳钢的临界超声振幅为53.8 μm,当振幅小于53.8 μm时,空化腐蚀过程中的腐蚀效应大于机械效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of Ultrasonic Amplitude on Electrochemical Properties During Cavitation of Carbon Steel in 3.5% NaCl Solution
Cavitation corrosion in many industrial plants has recently become a serious issue. Cavitation corrosion has generally been investigated using a vibratory method based on ASTM G32 standard, and the test can be divided into direct cavitation and indirect cavitation. Cavitation corrosion test uses the vibration frequency of the horn of 20 kHz with constant peak-to-peak displacement amplitude. In this work, the peak-to-peak amplitude was controlled from 15 μm to 85 μm, and electrochemical measurements were obtained during indirect cavitation. The relationship between cavitation corrosion rate and electrochemical properties was discussed. Corrosion steps of carbon steel at the initial stage under cavitation condition in 3.5 % NaCl can be proposed. When the cavitation strength is relatively low, corrosion of the steel is more affected by the electrochemical process than by the mechanical process; but when the cavitation strength is relatively high, corrosion of the steel is affected more by the mechanical process than by the electrochemical process. This work confirmed that the critical ultrasonic amplitude of 0.42 %C carbon steel is 53.8 μm, and when the amplitude is less than 53.8 μm, the corrosion effect during the cavitation corrosion process is higher than the mechanical effect.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.30
自引率
66.70%
发文量
0
期刊最新文献
Effect of ε-carbide (Fe 2.4 C) on Corrosion and Hydrogen Diffusion Behaviors of Automotive Ultrahigh-Strength Steel Sheet, 초고강도급 자동차용 강재 내 ε-carbide (Fe 2.4 C)가 부식 및 수소확산거동에 미치는 영향 원자로 내부구조물 균열개시 민감도에 미치는 영향인자 고찰 Failure Evaluation Plan of a Reactor Internal Components of a Decommissioned Plant Electrochemical Characteristics of Synthesized Nb 2 O 5 -Li 3 VO 4 Composites as Li Storage Materials Application of High Performance Coatings for Service Life Extension of Steel Bridge Coatings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1