{"title":"利用铜痕迹尖端评价无铅焊料的电迁移电阻","authors":"K. Hino, M. Saka","doi":"10.1504/IJMSI.2015.075827","DOIUrl":null,"url":null,"abstract":"Owing to the miniaturisation of solder bump connections, evaluations of the electromigration (EM) resistance of various lead-free solders have become increasingly important. In this paper, by utilising the sharp tip of a Cu trace, a simple method including easy sample preparation is proposed for EM resistance evaluation. The sample is prepared by surrounding the Cu traces with solder, and the EM resistance is evaluated by supplying a current between the traces. The current flows in the anode trace and flows from its sharp tip to the solder. The total volume of observed hillocks in the designated area near the tip of the Cu trace per unit time of current supply is used to determine the EM resistance. Rankings of the EM resistance in various solders under the same supplied current and sample temperature are theoretically proven to be invariable, regardless of their values. For testing materials, Sn-3.0Ag-0.5Cu and Sn-3.5Ag-0.5Cu-0.07Ni-0.01Ge solders (wt %) are used with 4N (99.99%) purity Sn as a reference. The usefulness of the present method is demonstrated by evaluating the EM resistance of these solders.","PeriodicalId":39035,"journal":{"name":"International Journal of Materials and Structural Integrity","volume":"20 1","pages":"216"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1504/IJMSI.2015.075827","citationCount":"0","resultStr":"{\"title\":\"Evaluating the electromigration resistance of lead-free solders by utilising the sharp tip of a Cu trace\",\"authors\":\"K. Hino, M. Saka\",\"doi\":\"10.1504/IJMSI.2015.075827\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Owing to the miniaturisation of solder bump connections, evaluations of the electromigration (EM) resistance of various lead-free solders have become increasingly important. In this paper, by utilising the sharp tip of a Cu trace, a simple method including easy sample preparation is proposed for EM resistance evaluation. The sample is prepared by surrounding the Cu traces with solder, and the EM resistance is evaluated by supplying a current between the traces. The current flows in the anode trace and flows from its sharp tip to the solder. The total volume of observed hillocks in the designated area near the tip of the Cu trace per unit time of current supply is used to determine the EM resistance. Rankings of the EM resistance in various solders under the same supplied current and sample temperature are theoretically proven to be invariable, regardless of their values. For testing materials, Sn-3.0Ag-0.5Cu and Sn-3.5Ag-0.5Cu-0.07Ni-0.01Ge solders (wt %) are used with 4N (99.99%) purity Sn as a reference. The usefulness of the present method is demonstrated by evaluating the EM resistance of these solders.\",\"PeriodicalId\":39035,\"journal\":{\"name\":\"International Journal of Materials and Structural Integrity\",\"volume\":\"20 1\",\"pages\":\"216\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1504/IJMSI.2015.075827\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Materials and Structural Integrity\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/IJMSI.2015.075827\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Materials and Structural Integrity","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJMSI.2015.075827","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
摘要
由于凸锡连接的小型化,各种无铅焊料的电迁移(EM)电阻的评估变得越来越重要。本文提出了一种利用铜痕量的尖端进行电磁电阻评估的简单方法。样品是通过用焊料包围Cu走线来制备的,并且通过在走线之间提供电流来评估EM电阻。电流在阳极迹线中流动,并从其尖端流向焊料。在单位时间的电流供应中,在铜走线尖端附近的指定区域观察到的丘的总体积用于确定电磁电阻。在相同的供电电流和样品温度下,无论其值如何,理论上证明各种焊料中的电磁电阻排名是不变的。测试材料采用Sn-3.0 ag -0.5 cu和Sn-3.5 ag -0.5 cu -0.07 ni -0.01 ge焊料(wt %),以4N(99.99%)纯度Sn为基准。通过对这些焊料的电磁电阻进行评估,证明了本方法的有效性。
Evaluating the electromigration resistance of lead-free solders by utilising the sharp tip of a Cu trace
Owing to the miniaturisation of solder bump connections, evaluations of the electromigration (EM) resistance of various lead-free solders have become increasingly important. In this paper, by utilising the sharp tip of a Cu trace, a simple method including easy sample preparation is proposed for EM resistance evaluation. The sample is prepared by surrounding the Cu traces with solder, and the EM resistance is evaluated by supplying a current between the traces. The current flows in the anode trace and flows from its sharp tip to the solder. The total volume of observed hillocks in the designated area near the tip of the Cu trace per unit time of current supply is used to determine the EM resistance. Rankings of the EM resistance in various solders under the same supplied current and sample temperature are theoretically proven to be invariable, regardless of their values. For testing materials, Sn-3.0Ag-0.5Cu and Sn-3.5Ag-0.5Cu-0.07Ni-0.01Ge solders (wt %) are used with 4N (99.99%) purity Sn as a reference. The usefulness of the present method is demonstrated by evaluating the EM resistance of these solders.