{"title":"离心浇铸带有非金属钢筋的混凝土杆","authors":"","doi":"10.14256/jce.3246.2021","DOIUrl":null,"url":null,"abstract":"The article describes the testing of poles for electric power transmission lines, which are made of centrifugally-cast concrete and ultra-high strength concrete, and which are prestressed with Carbon Fibre Reinforced Polymer tendons (CFRP). The presented results of pole ultimate load testing suggest the potential for usage of this construction product, particularly in aggressive environments with high probability of steel corrosion. Part of the tested poles had shear reinforcement in the form of confined Glass Fibre Reinforced Polymer (GFRP) grid, while one share of samples had no shear reinforcement, but the concrete matrix was strengthened with synthetic macro fibres. A review is given on similar product testing, calculation methods, and guidance is provided for further research.","PeriodicalId":50415,"journal":{"name":"Gradevinar","volume":"1 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2021-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Centrifugally-cast concrete poles with non-metallic reinforcement\",\"authors\":\"\",\"doi\":\"10.14256/jce.3246.2021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article describes the testing of poles for electric power transmission lines, which are made of centrifugally-cast concrete and ultra-high strength concrete, and which are prestressed with Carbon Fibre Reinforced Polymer tendons (CFRP). The presented results of pole ultimate load testing suggest the potential for usage of this construction product, particularly in aggressive environments with high probability of steel corrosion. Part of the tested poles had shear reinforcement in the form of confined Glass Fibre Reinforced Polymer (GFRP) grid, while one share of samples had no shear reinforcement, but the concrete matrix was strengthened with synthetic macro fibres. A review is given on similar product testing, calculation methods, and guidance is provided for further research.\",\"PeriodicalId\":50415,\"journal\":{\"name\":\"Gradevinar\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2021-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Gradevinar\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.14256/jce.3246.2021\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gradevinar","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.14256/jce.3246.2021","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
Centrifugally-cast concrete poles with non-metallic reinforcement
The article describes the testing of poles for electric power transmission lines, which are made of centrifugally-cast concrete and ultra-high strength concrete, and which are prestressed with Carbon Fibre Reinforced Polymer tendons (CFRP). The presented results of pole ultimate load testing suggest the potential for usage of this construction product, particularly in aggressive environments with high probability of steel corrosion. Part of the tested poles had shear reinforcement in the form of confined Glass Fibre Reinforced Polymer (GFRP) grid, while one share of samples had no shear reinforcement, but the concrete matrix was strengthened with synthetic macro fibres. A review is given on similar product testing, calculation methods, and guidance is provided for further research.