基于超声视频处理的丸流检测方法评价吞咽

IF 0.8 Q4 ENGINEERING, BIOMEDICAL Advanced Biomedical Engineering Pub Date : 2021-01-01 DOI:10.14326/ABE.10.18
Takato Matsuzaki, Yutaka Suzuki, M. Tanimoto, Keisuke Masuyama, Masashi Osano, O. Sakata, M. Morisawa
{"title":"基于超声视频处理的丸流检测方法评价吞咽","authors":"Takato Matsuzaki, Yutaka Suzuki, M. Tanimoto, Keisuke Masuyama, Masashi Osano, O. Sakata, M. Morisawa","doi":"10.14326/ABE.10.18","DOIUrl":null,"url":null,"abstract":"To prevent aspiration pneumonia, a system for non-invasive and quantitative evaluation of the swallowing function is required. Therefore, we have previously proposed a method of using ultrasound videos to establish evaluation indicators of the swallowing function. The proposed method aims to automatically estimate the velocities of the esophageal wall region and the bolus region in the ultrasound video. In this method, estimation of the bolus region comprises two steps: estimating the esophageal region through which the bolus flows and extracting only the frame in which the bolus passes through the esophageal region. However, the step of extracting the frame in which the bolus passes is still performed manually. Therefore, to automate this step, the purpose of this study was to automatically determine the frame in which the bolus flowed into the screen. This method was tested five times on five healthy adult male subjects by recording a cervical ultrasound video while swallowing a bolus of water. We identified the different elements of the esophageal region in the video by first identifying the esophageal wall region with the maximally stable extremal regions (MSER). Then, we used the luminance histogram of each frame to establish the graph of the histogram similarity. This, in turn, was used to detect a change in the observed region, thus indicating the inflow of the bolus. Moreover, we could distinguish the change caused by the inflow from the change caused by the elevation of the esophageal wall using the velocity results obtained by optical flow estimation in the anterior esophageal wall region. Our results showed that in most cases, the proposed method was successful in recognizing the inflow of the bolus and distinguishing it from the elevation of the esophageal wall. Furthermore, an accuracy sufficient for estimation of the velocity of the bolus was achieved. optical flow, esophagus, bolus, maximally stable extremal regions.","PeriodicalId":54017,"journal":{"name":"Advanced Biomedical Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Bolus Inflow Detection Method by Ultrasound Video Processing for Evaluation of Swallowing\",\"authors\":\"Takato Matsuzaki, Yutaka Suzuki, M. Tanimoto, Keisuke Masuyama, Masashi Osano, O. Sakata, M. Morisawa\",\"doi\":\"10.14326/ABE.10.18\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To prevent aspiration pneumonia, a system for non-invasive and quantitative evaluation of the swallowing function is required. Therefore, we have previously proposed a method of using ultrasound videos to establish evaluation indicators of the swallowing function. The proposed method aims to automatically estimate the velocities of the esophageal wall region and the bolus region in the ultrasound video. In this method, estimation of the bolus region comprises two steps: estimating the esophageal region through which the bolus flows and extracting only the frame in which the bolus passes through the esophageal region. However, the step of extracting the frame in which the bolus passes is still performed manually. Therefore, to automate this step, the purpose of this study was to automatically determine the frame in which the bolus flowed into the screen. This method was tested five times on five healthy adult male subjects by recording a cervical ultrasound video while swallowing a bolus of water. We identified the different elements of the esophageal region in the video by first identifying the esophageal wall region with the maximally stable extremal regions (MSER). Then, we used the luminance histogram of each frame to establish the graph of the histogram similarity. This, in turn, was used to detect a change in the observed region, thus indicating the inflow of the bolus. Moreover, we could distinguish the change caused by the inflow from the change caused by the elevation of the esophageal wall using the velocity results obtained by optical flow estimation in the anterior esophageal wall region. Our results showed that in most cases, the proposed method was successful in recognizing the inflow of the bolus and distinguishing it from the elevation of the esophageal wall. Furthermore, an accuracy sufficient for estimation of the velocity of the bolus was achieved. optical flow, esophagus, bolus, maximally stable extremal regions.\",\"PeriodicalId\":54017,\"journal\":{\"name\":\"Advanced Biomedical Engineering\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Biomedical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14326/ABE.10.18\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14326/ABE.10.18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

摘要

为了预防吸入性肺炎,需要一种对吞咽功能进行非侵入性定量评估的系统。因此,我们之前提出了一种利用超声视频建立吞咽功能评价指标的方法。该方法旨在自动估计超声视频中食管壁区域和丸区速度。在该方法中,丸剂区域的估计包括两个步骤:估计丸剂流经的食道区域和仅提取丸剂流经食道区域的帧。然而,提取小球经过的帧的步骤仍然是手动执行的。因此,为了使这一步骤自动化,本研究的目的是自动确定药丸流入屏幕的帧。该方法在五名健康成年男性受试者身上进行了五次测试,在吞咽一团水的同时记录宫颈超声视频。在视频中,我们首先通过最大稳定极区(MSER)识别食管壁区域,从而确定了食管区域的不同组成部分。然后,我们利用每帧的亮度直方图建立直方图相似度图。反过来,这被用来检测观察区域的变化,从而表明丸的流入。此外,我们可以利用光流估计在食管壁前区得到的速度结果来区分流入引起的变化和食管壁升高引起的变化。我们的结果表明,在大多数情况下,所提出的方法可以成功地识别出丸的流入,并将其与食管壁的升高区分开来。此外,还获得了足够的速度估计精度。光流,食道,丸,最稳定的极端区域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bolus Inflow Detection Method by Ultrasound Video Processing for Evaluation of Swallowing
To prevent aspiration pneumonia, a system for non-invasive and quantitative evaluation of the swallowing function is required. Therefore, we have previously proposed a method of using ultrasound videos to establish evaluation indicators of the swallowing function. The proposed method aims to automatically estimate the velocities of the esophageal wall region and the bolus region in the ultrasound video. In this method, estimation of the bolus region comprises two steps: estimating the esophageal region through which the bolus flows and extracting only the frame in which the bolus passes through the esophageal region. However, the step of extracting the frame in which the bolus passes is still performed manually. Therefore, to automate this step, the purpose of this study was to automatically determine the frame in which the bolus flowed into the screen. This method was tested five times on five healthy adult male subjects by recording a cervical ultrasound video while swallowing a bolus of water. We identified the different elements of the esophageal region in the video by first identifying the esophageal wall region with the maximally stable extremal regions (MSER). Then, we used the luminance histogram of each frame to establish the graph of the histogram similarity. This, in turn, was used to detect a change in the observed region, thus indicating the inflow of the bolus. Moreover, we could distinguish the change caused by the inflow from the change caused by the elevation of the esophageal wall using the velocity results obtained by optical flow estimation in the anterior esophageal wall region. Our results showed that in most cases, the proposed method was successful in recognizing the inflow of the bolus and distinguishing it from the elevation of the esophageal wall. Furthermore, an accuracy sufficient for estimation of the velocity of the bolus was achieved. optical flow, esophagus, bolus, maximally stable extremal regions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Advanced Biomedical Engineering
Advanced Biomedical Engineering ENGINEERING, BIOMEDICAL-
CiteScore
1.40
自引率
10.00%
发文量
15
审稿时长
15 weeks
期刊最新文献
SATORI: Amplification-free digital RNA detection method for the diagnosis of viral infections. Basic Investigation of the Effect of Insole Shape on Leg Skeletal Muscle Mass and Pressure Changes during Walking Investigating Mental Task Combination for Brain-Computer Interface Based on Brain State Discrimination Using Subjective Ratings Development of Beat Analysis Software for the Non-invasive Evaluation of Cardiac Constructs Fabricated with a Three-dimensional Bioprinter Transepidermal Water Loss Estimation Model for Evaluating Skin Barrier Function
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1