测定铅离子的电位传感器

Q4 Chemistry Analitika i Kontrol Pub Date : 2021-01-01 DOI:10.15826/analitika.2021.25.3.002
S. D. Tataeva, R. Z. Zeynalov, K. E. Magomedov
{"title":"测定铅离子的电位传感器","authors":"S. D. Tataeva, R. Z. Zeynalov, K. E. Magomedov","doi":"10.15826/analitika.2021.25.3.002","DOIUrl":null,"url":null,"abstract":"One of the sensitive and inexpensive methods used for the analysis of water bodies is the ionometry, the development of which is associated with the introduction of new ion-selective electrodes into the practice of potentiometric analysis. An optimized composition of the membrane for the manufacturing of a zinc-selective electrode based on polyvinyl chloride modified with 2-mercaptobenzthiazole (MPVC) is proposed with the following ratio of ingredients (in wt. %): Polyvinyl chloride - 31.7; dioctyl sebacate - 66.3; potassium tetra-p-chlorophenylborate - 0.5; MPVH - 1.5. The working range of pH was established with a minimum potential drift, which was 1.5 - 3. The slope of the electrode function was calculated as 30.1 ± 0.3 mV. According to the dependence of the electrode potential for the selected composition of the membrane on the logarithm of the zinc ion concentration, it was found that the proposed model of the electrode operates in the concentration range of 1∙10-5 - 1∙10-1 mol / L, with a detection limit of 0.65 mg / l. The stabilization time of the potential within 1 mV was 15 - 20 s. The potentiometric coefficients of the selectivity of the zinc selective electrode with respect to various ions have been determined. The conditions for the determination of zinc using the obtained sensor in alloys and wastewater were proposed. The electrode with the membrane based on polyvinyl chloride modified with 2-mercaptobenzthiazole can be used as an alternative to the industrial electrode XC-Zn-001 for the determination of zinc ions in various objects. The obtained experimental data was close in accuracy to the results obtained by the atomic absorption methods, as well as the ionometry using the industrial electrode. In conclusion, the electrode with the membrane based on polyvinyl chloride modified with 2-mercaptobenzthiazole can be used as an alternative to XC-Zn-001.","PeriodicalId":37743,"journal":{"name":"Analitika i Kontrol","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Potentiometric sensor for lead ions determination\",\"authors\":\"S. D. Tataeva, R. Z. Zeynalov, K. E. Magomedov\",\"doi\":\"10.15826/analitika.2021.25.3.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the sensitive and inexpensive methods used for the analysis of water bodies is the ionometry, the development of which is associated with the introduction of new ion-selective electrodes into the practice of potentiometric analysis. An optimized composition of the membrane for the manufacturing of a zinc-selective electrode based on polyvinyl chloride modified with 2-mercaptobenzthiazole (MPVC) is proposed with the following ratio of ingredients (in wt. %): Polyvinyl chloride - 31.7; dioctyl sebacate - 66.3; potassium tetra-p-chlorophenylborate - 0.5; MPVH - 1.5. The working range of pH was established with a minimum potential drift, which was 1.5 - 3. The slope of the electrode function was calculated as 30.1 ± 0.3 mV. According to the dependence of the electrode potential for the selected composition of the membrane on the logarithm of the zinc ion concentration, it was found that the proposed model of the electrode operates in the concentration range of 1∙10-5 - 1∙10-1 mol / L, with a detection limit of 0.65 mg / l. The stabilization time of the potential within 1 mV was 15 - 20 s. The potentiometric coefficients of the selectivity of the zinc selective electrode with respect to various ions have been determined. The conditions for the determination of zinc using the obtained sensor in alloys and wastewater were proposed. The electrode with the membrane based on polyvinyl chloride modified with 2-mercaptobenzthiazole can be used as an alternative to the industrial electrode XC-Zn-001 for the determination of zinc ions in various objects. The obtained experimental data was close in accuracy to the results obtained by the atomic absorption methods, as well as the ionometry using the industrial electrode. In conclusion, the electrode with the membrane based on polyvinyl chloride modified with 2-mercaptobenzthiazole can be used as an alternative to XC-Zn-001.\",\"PeriodicalId\":37743,\"journal\":{\"name\":\"Analitika i Kontrol\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analitika i Kontrol\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15826/analitika.2021.25.3.002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analitika i Kontrol","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15826/analitika.2021.25.3.002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 0

摘要

离子测定法是用于分析水体的一种灵敏而廉价的方法,它的发展与在电位测定分析中引入新的离子选择电极有关。提出了以2-巯基苯并噻唑(MPVC)改性聚氯乙烯为基础制备锌选择电极的膜的优化组合,其配比(wt. %)为:聚氯乙烯- 31.7;癸酸二辛酯- 66.3;四对氯苯硼酸钾- 0.5;MPVH - 1.5。pH值的工作范围为最小电位漂移1.5 ~ 3。计算电极函数的斜率为30.1±0.3 mV。根据所选膜组分的电极电位与锌离子浓度的对数关系,发现所提出的电极模型在1∙10-5 -1∙10-1 mol / L浓度范围内工作,检出限为0.65 mg / L, 1 mV内电位稳定时间为15 ~ 20 s。测定了锌选择电极对各种离子选择性的电位系数。提出了用该传感器测定合金和废水中锌的条件。2-巯基苯并噻唑改性聚氯乙烯膜电极可替代工业电极XC-Zn-001,用于各种物体中锌离子的测定。所得的实验数据与原子吸收法和工业电极离子测定法的结果精度接近。综上所述,2-巯基苯并噻唑修饰的聚氯乙烯基膜电极可以作为XC-Zn-001的替代品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Potentiometric sensor for lead ions determination
One of the sensitive and inexpensive methods used for the analysis of water bodies is the ionometry, the development of which is associated with the introduction of new ion-selective electrodes into the practice of potentiometric analysis. An optimized composition of the membrane for the manufacturing of a zinc-selective electrode based on polyvinyl chloride modified with 2-mercaptobenzthiazole (MPVC) is proposed with the following ratio of ingredients (in wt. %): Polyvinyl chloride - 31.7; dioctyl sebacate - 66.3; potassium tetra-p-chlorophenylborate - 0.5; MPVH - 1.5. The working range of pH was established with a minimum potential drift, which was 1.5 - 3. The slope of the electrode function was calculated as 30.1 ± 0.3 mV. According to the dependence of the electrode potential for the selected composition of the membrane on the logarithm of the zinc ion concentration, it was found that the proposed model of the electrode operates in the concentration range of 1∙10-5 - 1∙10-1 mol / L, with a detection limit of 0.65 mg / l. The stabilization time of the potential within 1 mV was 15 - 20 s. The potentiometric coefficients of the selectivity of the zinc selective electrode with respect to various ions have been determined. The conditions for the determination of zinc using the obtained sensor in alloys and wastewater were proposed. The electrode with the membrane based on polyvinyl chloride modified with 2-mercaptobenzthiazole can be used as an alternative to the industrial electrode XC-Zn-001 for the determination of zinc ions in various objects. The obtained experimental data was close in accuracy to the results obtained by the atomic absorption methods, as well as the ionometry using the industrial electrode. In conclusion, the electrode with the membrane based on polyvinyl chloride modified with 2-mercaptobenzthiazole can be used as an alternative to XC-Zn-001.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analitika i Kontrol
Analitika i Kontrol Chemistry-Analytical Chemistry
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: Analitika i Kontrol is a scientific journal covering theoretical and applied aspects of analytical chemistry and analytical control, published since autumn 1997. Founder and publisher of the journal is the Ural Federal University named after the first President of Russia Boris Yeltsin (UrFU, Ekaterinburg).
期刊最新文献
Electrophoretic determination of carboxylic acids in blood serum with intracapillary concentration Fluorescence of anisotropic primary X-ray radiation Selection of the parameters of a multicapillary column for portable gas analyzers by Kovach indices Differentiation of oil samples by isomeric composition of paraffins using cluster analysis methods Important features of retention indices determination in reversed-phase high performance liquid chromatography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1