Cyntia Cristinne Corrêa Baia de Aquino, T. M. Blasi, C. Unsihuay-Vila, T. Fernandes, Rafael Silva Pinto, Mauro Obladen de Lara Filho, A. R. Aoki, Fabricio H. Tabarro, Rodrigo Braun dos Santos
{"title":"多微电网有源配电网日前优化运行规划的层次框架","authors":"Cyntia Cristinne Corrêa Baia de Aquino, T. M. Blasi, C. Unsihuay-Vila, T. Fernandes, Rafael Silva Pinto, Mauro Obladen de Lara Filho, A. R. Aoki, Fabricio H. Tabarro, Rodrigo Braun dos Santos","doi":"10.1590/1678-4324-2023220379","DOIUrl":null,"url":null,"abstract":": The insertion of new distributed energy resources, such as distributed generation (DG), energy storage systems (ESS), demand response (DR), and microgrids (MG), is emerging, bringing new challenges to the current distribution network. In this regard, the active distribution networks (ADN) with multi-microgrids concept appears. The present paper proposes a hierarchical (master-slave problem) computational model to achieve optimal coordinated operation of multi-microgrids connected to an ADN. Day-ahead operation planning of an ADN was formulated as a multiperiod non-linear optimal power flow model, resulting in a non-linear optimization problem, additionally, the day-ahead operation planning of MGs was formulated as a multiperiod linearized optimal power flow resulting in a mixed-integer linear optimization problem. Numerical results on four different test-system microgrids connected to a 359-nodes ADNs test-system belonging to a Brazilian distribution company show the effectiveness of the proposed model and solution strategy. Three cases have been tested: with a maximum load-shedding restriction, without this restriction, and considering insertion of DG. Besides, the hierarchical model can evaluate how much losses and load shedding take effect","PeriodicalId":9169,"journal":{"name":"Brazilian Archives of Biology and Technology","volume":"16 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2023-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Hierarchical Framework for Day-Ahead Optimal Operation Planning of Active Distribution Networks with Multi-Microgrids\",\"authors\":\"Cyntia Cristinne Corrêa Baia de Aquino, T. M. Blasi, C. Unsihuay-Vila, T. Fernandes, Rafael Silva Pinto, Mauro Obladen de Lara Filho, A. R. Aoki, Fabricio H. Tabarro, Rodrigo Braun dos Santos\",\"doi\":\"10.1590/1678-4324-2023220379\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": The insertion of new distributed energy resources, such as distributed generation (DG), energy storage systems (ESS), demand response (DR), and microgrids (MG), is emerging, bringing new challenges to the current distribution network. In this regard, the active distribution networks (ADN) with multi-microgrids concept appears. The present paper proposes a hierarchical (master-slave problem) computational model to achieve optimal coordinated operation of multi-microgrids connected to an ADN. Day-ahead operation planning of an ADN was formulated as a multiperiod non-linear optimal power flow model, resulting in a non-linear optimization problem, additionally, the day-ahead operation planning of MGs was formulated as a multiperiod linearized optimal power flow resulting in a mixed-integer linear optimization problem. Numerical results on four different test-system microgrids connected to a 359-nodes ADNs test-system belonging to a Brazilian distribution company show the effectiveness of the proposed model and solution strategy. Three cases have been tested: with a maximum load-shedding restriction, without this restriction, and considering insertion of DG. Besides, the hierarchical model can evaluate how much losses and load shedding take effect\",\"PeriodicalId\":9169,\"journal\":{\"name\":\"Brazilian Archives of Biology and Technology\",\"volume\":\"16 1\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brazilian Archives of Biology and Technology\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1590/1678-4324-2023220379\",\"RegionNum\":4,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Archives of Biology and Technology","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1590/1678-4324-2023220379","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOLOGY","Score":null,"Total":0}
A Hierarchical Framework for Day-Ahead Optimal Operation Planning of Active Distribution Networks with Multi-Microgrids
: The insertion of new distributed energy resources, such as distributed generation (DG), energy storage systems (ESS), demand response (DR), and microgrids (MG), is emerging, bringing new challenges to the current distribution network. In this regard, the active distribution networks (ADN) with multi-microgrids concept appears. The present paper proposes a hierarchical (master-slave problem) computational model to achieve optimal coordinated operation of multi-microgrids connected to an ADN. Day-ahead operation planning of an ADN was formulated as a multiperiod non-linear optimal power flow model, resulting in a non-linear optimization problem, additionally, the day-ahead operation planning of MGs was formulated as a multiperiod linearized optimal power flow resulting in a mixed-integer linear optimization problem. Numerical results on four different test-system microgrids connected to a 359-nodes ADNs test-system belonging to a Brazilian distribution company show the effectiveness of the proposed model and solution strategy. Three cases have been tested: with a maximum load-shedding restriction, without this restriction, and considering insertion of DG. Besides, the hierarchical model can evaluate how much losses and load shedding take effect