从主动脉弓的总开口经桡动脉通道机械取栓在头臂干和左颈总动脉起源变异中的应用

B. Sharafutdinov, S. A. Ryzhkin, E. A. Gaziev, I. V. Abdul’yanov, A. Abashev, M. K. Mikhaylov
{"title":"从主动脉弓的总开口经桡动脉通道机械取栓在头臂干和左颈总动脉起源变异中的应用","authors":"B. Sharafutdinov, S. A. Ryzhkin, E. A. Gaziev, I. V. Abdul’yanov, A. Abashev, M. K. Mikhaylov","doi":"10.20862/0042-4676-2020-101-2-126-130","DOIUrl":null,"url":null,"abstract":"The paper describes a clinical case of successfully applying a transradial access during mechanical thrombus extraction in a patient in the acutest stage of ischemic stroke with a congenital anatomical feature (the left common carotid artery and brachiocephalic trunk with the common ostium from the aortic arch).X-ray endovascular interventions were performed in an operating room equipped with a digital angiographic unit including an Axiom Artis dTA flat detector (Siemens Medical System).Mechanical recanalization for acute occlusion of the M2 segment of the left middle cerebral artery (MCA) was carried out using a right radial access into and catheterization of the left internal carotid artery. A stent retriever was inserted into the occlusion area through a microcatheter and was opened. Double thrombus extraction from the left MCA was made using the stent retriever to restore TICI 2B blood flow. There were no signs of dissection, thrombosis, or distal thromboembolism.","PeriodicalId":34090,"journal":{"name":"Vestnik rentgenologii i radiologii","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Mechanical Thrombectomy Using Transradial Access in a Variation of the Origin of the Brachiocephalic Trunk and Left Common Carotid Artery by the Common Ostium from the Aortic Arch\",\"authors\":\"B. Sharafutdinov, S. A. Ryzhkin, E. A. Gaziev, I. V. Abdul’yanov, A. Abashev, M. K. Mikhaylov\",\"doi\":\"10.20862/0042-4676-2020-101-2-126-130\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper describes a clinical case of successfully applying a transradial access during mechanical thrombus extraction in a patient in the acutest stage of ischemic stroke with a congenital anatomical feature (the left common carotid artery and brachiocephalic trunk with the common ostium from the aortic arch).X-ray endovascular interventions were performed in an operating room equipped with a digital angiographic unit including an Axiom Artis dTA flat detector (Siemens Medical System).Mechanical recanalization for acute occlusion of the M2 segment of the left middle cerebral artery (MCA) was carried out using a right radial access into and catheterization of the left internal carotid artery. A stent retriever was inserted into the occlusion area through a microcatheter and was opened. Double thrombus extraction from the left MCA was made using the stent retriever to restore TICI 2B blood flow. There were no signs of dissection, thrombosis, or distal thromboembolism.\",\"PeriodicalId\":34090,\"journal\":{\"name\":\"Vestnik rentgenologii i radiologii\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vestnik rentgenologii i radiologii\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20862/0042-4676-2020-101-2-126-130\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik rentgenologii i radiologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20862/0042-4676-2020-101-2-126-130","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了一例先天性缺血性中风急性期(左颈总动脉和头臂干与主动脉弓的总开口)患者机械取栓时成功应用经桡动脉通路的临床病例。x线血管内介入手术在配备数字血管造影设备的手术室进行,其中包括Axiom Artis dTA平面探测器(西门子医疗系统)。机械再通术治疗急性闭塞的左大脑中动脉(MCA) M2段,采用右桡动脉通道进入左颈内动脉插管。支架取出器通过微导管插入闭塞区并打开。使用支架回收器从左MCA取出双血栓,恢复TICI 2B血流。没有解剖、血栓形成或远端血栓栓塞的迹象。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mechanical Thrombectomy Using Transradial Access in a Variation of the Origin of the Brachiocephalic Trunk and Left Common Carotid Artery by the Common Ostium from the Aortic Arch
The paper describes a clinical case of successfully applying a transradial access during mechanical thrombus extraction in a patient in the acutest stage of ischemic stroke with a congenital anatomical feature (the left common carotid artery and brachiocephalic trunk with the common ostium from the aortic arch).X-ray endovascular interventions were performed in an operating room equipped with a digital angiographic unit including an Axiom Artis dTA flat detector (Siemens Medical System).Mechanical recanalization for acute occlusion of the M2 segment of the left middle cerebral artery (MCA) was carried out using a right radial access into and catheterization of the left internal carotid artery. A stent retriever was inserted into the occlusion area through a microcatheter and was opened. Double thrombus extraction from the left MCA was made using the stent retriever to restore TICI 2B blood flow. There were no signs of dissection, thrombosis, or distal thromboembolism.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
24
审稿时长
36 weeks
期刊最新文献
Comparative Reproducibility Analysis of Thoracic Aorta Morphometric Parameters According to Computed Tomography and Magnetic Resonance Angiography Radiological Features of Changes in the Lungs Caused by Fast- or Slow-Growing Nontuberculous Mycobacteria To Help the Practitioner: Imaging of Ovarian Masses According to the O-RADS MRI Ovarian Malignancy Categorical Risk Scale Experience in Using Breast Single-Photon Emission Computed Tomography with <sup>99m</sup>Tc-MIBI Differential Diagnosis of Fibrotic Hypersensitivity Pneumonitis with Its Non-Fibrotic Phenotype and Usual Interstitial Pneumonia During High-Resolution Computed Tomography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1