FL-APC直流-交流变换器的故障分析与排除

IF 2.1 Q3 COMPUTER SCIENCE, HARDWARE & ARCHITECTURE IEEE Canadian Journal of Electrical and Computer Engineering Pub Date : 2023-02-22 DOI:10.1109/ICJECE.2022.3220090
K. Suresh;E. Parimalasundar
{"title":"FL-APC直流-交流变换器的故障分析与排除","authors":"K. Suresh;E. Parimalasundar","doi":"10.1109/ICJECE.2022.3220090","DOIUrl":null,"url":null,"abstract":"The traditional active neutral-point-clamped (APC) dc–ac converter maintains great common-mode voltage with high-frequency (CMV-HF) reduction capability, so it has limited voltage gain. This article presents a new five-level APC (FL-APC) dc–ac converter capable of voltage step-up in a single-stage inversion. In the suggested design, a common ground not only reduces the CMV-HF but also improves dc-link voltage usage. While comparing with traditional two-stage FL-APC dc–ac converter, the proposed design has lower voltage stresses and greater uniformity. While improving overall efficiency, the suggested clamped dc–ac converter saves three power switches and a capacitor. Modeling and actual tests have proven the suggested APC inverter’s overall operation, efficacy, and achievability. The proposed circuit is finally tested with fault clearance capability.","PeriodicalId":100619,"journal":{"name":"IEEE Canadian Journal of Electrical and Computer Engineering","volume":"46 1","pages":"1-6"},"PeriodicalIF":2.1000,"publicationDate":"2023-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Fault Analysis and Clearance in FL-APC DC–AC Converter\",\"authors\":\"K. Suresh;E. Parimalasundar\",\"doi\":\"10.1109/ICJECE.2022.3220090\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The traditional active neutral-point-clamped (APC) dc–ac converter maintains great common-mode voltage with high-frequency (CMV-HF) reduction capability, so it has limited voltage gain. This article presents a new five-level APC (FL-APC) dc–ac converter capable of voltage step-up in a single-stage inversion. In the suggested design, a common ground not only reduces the CMV-HF but also improves dc-link voltage usage. While comparing with traditional two-stage FL-APC dc–ac converter, the proposed design has lower voltage stresses and greater uniformity. While improving overall efficiency, the suggested clamped dc–ac converter saves three power switches and a capacitor. Modeling and actual tests have proven the suggested APC inverter’s overall operation, efficacy, and achievability. The proposed circuit is finally tested with fault clearance capability.\",\"PeriodicalId\":100619,\"journal\":{\"name\":\"IEEE Canadian Journal of Electrical and Computer Engineering\",\"volume\":\"46 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-02-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Canadian Journal of Electrical and Computer Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10050346/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"COMPUTER SCIENCE, HARDWARE & ARCHITECTURE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Canadian Journal of Electrical and Computer Engineering","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10050346/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, HARDWARE & ARCHITECTURE","Score":null,"Total":0}
引用次数: 8

摘要

传统的有源中性点箝位(APC)直流-交流变换器具有高共模电压和高频(CMV-HF)降低能力,因此其电压增益有限。本文提出了一种新的五电平APC(FL-APC)直流-交流转换器,能够在单级逆变中升压。在建议的设计中,公共接地不仅降低了CMV-HF,而且提高了直流链路电压的使用。与传统的两级FL-APC直流-交流变换器相比,该设计具有更低的电压应力和更大的均匀性。在提高整体效率的同时,建议的箝位直流-交流转换器节省了三个电源开关和一个电容器。建模和实际测试已经证明了所建议的APC逆变器的整体操作、有效性和可实现性。最后对所提出的电路进行了故障清除能力测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fault Analysis and Clearance in FL-APC DC–AC Converter
The traditional active neutral-point-clamped (APC) dc–ac converter maintains great common-mode voltage with high-frequency (CMV-HF) reduction capability, so it has limited voltage gain. This article presents a new five-level APC (FL-APC) dc–ac converter capable of voltage step-up in a single-stage inversion. In the suggested design, a common ground not only reduces the CMV-HF but also improves dc-link voltage usage. While comparing with traditional two-stage FL-APC dc–ac converter, the proposed design has lower voltage stresses and greater uniformity. While improving overall efficiency, the suggested clamped dc–ac converter saves three power switches and a capacitor. Modeling and actual tests have proven the suggested APC inverter’s overall operation, efficacy, and achievability. The proposed circuit is finally tested with fault clearance capability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.70
自引率
0.00%
发文量
0
期刊最新文献
Table of Contents Front Cover IEEE Canadian Journal of Electrical and Computer Engineering Green Electricity Share Enhancement Through Rooftop Solar PV System on Institutional Sheds Enhanced Validation of Intelligent Control Algorithms in AC Microgrids
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1