用压阻式悬臂磁强计测量钴微细线的磁性能

IF 3.3 Q3 NANOSCIENCE & NANOTECHNOLOGY Nanofabrication Pub Date : 2014-09-19 DOI:10.2478/nanofab-2014-0008
G. Tosolini, J. Michalik, R. Córdoba, J. D. de Teresa, F. Pérez-Murano, J. Bausells
{"title":"用压阻式悬臂磁强计测量钴微细线的磁性能","authors":"G. Tosolini, J. Michalik, R. Córdoba, J. D. de Teresa, F. Pérez-Murano, J. Bausells","doi":"10.2478/nanofab-2014-0008","DOIUrl":null,"url":null,"abstract":"Abstract We present the magnetic characterization of cobalt wires grown by focused electron beam-induced deposition (FEBID) and studied using static piezoresistive cantilever magnetometry. We have used previously developed high force sensitive submicron-thick silicon piezoresistive cantilevers. High quality polycrystalline cobalt microwires have been grown by FEBID onto the free end of the cantilevers using dual beam equipment. In the presence of an external magnetic field, the magnetic cobalt wires become magnetized, which leads to the magnetic field dependent static deflection of the cantilevers. We show that the piezoresistive signal from the cantilevers, corresponding to a maximum force of about 1 nN, can be measured as a function of the applied magnetic field with a good signal to noise ratio at room temperature. The results highlight the flexibility of the FEBID technique for the growth of magnetic structures on specific substrates, in this case piezoresistive cantilevers.","PeriodicalId":51992,"journal":{"name":"Nanofabrication","volume":"1 1","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2014-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2478/nanofab-2014-0008","citationCount":"5","resultStr":"{\"title\":\"Magnetic properties of cobalt microwires measured by piezoresistive cantilever magnetometry\",\"authors\":\"G. Tosolini, J. Michalik, R. Córdoba, J. D. de Teresa, F. Pérez-Murano, J. Bausells\",\"doi\":\"10.2478/nanofab-2014-0008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract We present the magnetic characterization of cobalt wires grown by focused electron beam-induced deposition (FEBID) and studied using static piezoresistive cantilever magnetometry. We have used previously developed high force sensitive submicron-thick silicon piezoresistive cantilevers. High quality polycrystalline cobalt microwires have been grown by FEBID onto the free end of the cantilevers using dual beam equipment. In the presence of an external magnetic field, the magnetic cobalt wires become magnetized, which leads to the magnetic field dependent static deflection of the cantilevers. We show that the piezoresistive signal from the cantilevers, corresponding to a maximum force of about 1 nN, can be measured as a function of the applied magnetic field with a good signal to noise ratio at room temperature. The results highlight the flexibility of the FEBID technique for the growth of magnetic structures on specific substrates, in this case piezoresistive cantilevers.\",\"PeriodicalId\":51992,\"journal\":{\"name\":\"Nanofabrication\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2014-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2478/nanofab-2014-0008\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nanofabrication\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/nanofab-2014-0008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"NANOSCIENCE & NANOTECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nanofabrication","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/nanofab-2014-0008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NANOSCIENCE & NANOTECHNOLOGY","Score":null,"Total":0}
引用次数: 5

摘要

摘要本文介绍了聚焦电子束诱导沉积(FEBID)生长的钴丝的磁性特征,并利用静态压阻悬臂式磁强计对其进行了研究。我们已经使用了先前开发的高力敏亚微米厚硅压阻悬臂梁。利用双梁设备在悬臂梁的自由端生长出高质量的多晶钴微丝。在存在外部磁场的情况下,磁性钴线被磁化,这导致了依赖于磁场的悬臂梁的静态偏转。我们证明了悬臂梁的压阻信号,对应于大约1nn的最大力,可以作为外加磁场的函数来测量,在室温下具有良好的信噪比。结果突出了FEBID技术在特定基板上生长磁性结构的灵活性,在这种情况下是压阻悬臂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Magnetic properties of cobalt microwires measured by piezoresistive cantilever magnetometry
Abstract We present the magnetic characterization of cobalt wires grown by focused electron beam-induced deposition (FEBID) and studied using static piezoresistive cantilever magnetometry. We have used previously developed high force sensitive submicron-thick silicon piezoresistive cantilevers. High quality polycrystalline cobalt microwires have been grown by FEBID onto the free end of the cantilevers using dual beam equipment. In the presence of an external magnetic field, the magnetic cobalt wires become magnetized, which leads to the magnetic field dependent static deflection of the cantilevers. We show that the piezoresistive signal from the cantilevers, corresponding to a maximum force of about 1 nN, can be measured as a function of the applied magnetic field with a good signal to noise ratio at room temperature. The results highlight the flexibility of the FEBID technique for the growth of magnetic structures on specific substrates, in this case piezoresistive cantilevers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Nanofabrication
Nanofabrication NANOSCIENCE & NANOTECHNOLOGY-
自引率
10.30%
发文量
13
审稿时长
16 weeks
期刊最新文献
Recent updates on g-C3N4/ZnO-based binary and ternary heterojunction photocatalysts toward environmental remediation and energy conversion Lipid And Polymer Based Nano-Phytotherapeutics A Comprehensive Review of Nanocomposite PVDF as a Piezoelectric Material: Evaluating Manufacturing Methods, Energy Efficiency and Performance Nanocellulose-based Hydrogels: Preparation Strategies, Dye Adsorption and Factors Impacting Revisiting the advancement with painless microneedles for the diagnosis and treatment of dermal infections: A review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1