倍他洛尔(0.5%)眼液中苯扎氯铵稳定性指示高效液相色谱法的建立与验证

Liena Alagib H Edress, D. Elhag
{"title":"倍他洛尔(0.5%)眼液中苯扎氯铵稳定性指示高效液相色谱法的建立与验证","authors":"Liena Alagib H Edress, D. Elhag","doi":"10.26502/JPPR.0017","DOIUrl":null,"url":null,"abstract":"Background: Preservative assay in eye drops require the development of a suitable validated method for the assay. Objective: This study was conducted to develop and validate stability indicating High Performance Liquid Chromatography (HPLC) method for assay of benzalonium chloride in betaxolol 0.5% ophthalmic solution. Method: Method was developed validated according to International conference on harmonization (ICH) guideline. Chromatographic condition used was: L10 CN column (250 cm × 4.6 mm × 10 μm); flow rate 2.0 ml per minute; detection wavelength 245 nm; column oven 30°C; mobile phase: (0.1M sodium acetate, acetonitrile) (55:45 v/v) and injection volume 100 μL. Results: The method was found fulfilling the ICH requirement with R2 of 0.9995 for drug, Limit of detection (LOD) of 4.53 μg/ml, and Limit of quantification (LOQ) of 13.75 for benzalkonium chloride. The mean of overall recovery % was found to be 99.96% and the repeatability results was found to be: 99.95% for benzalkonium chloride. The overall intermediate precision results were found to be 100.77%. The method proved to be accurate, precise and specific. Conclusion: The developed method was found to be simple, sensitive and can be used for routine quality control analysis of benzalkonium chloride in betaxolol (0.5%) ophthalmic solutions.","PeriodicalId":73897,"journal":{"name":"Journal of pharmacy and pharmacology research","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development and Validation of Stability Indicating HPLC Method for Benzalkonium Chloride in Betaxolol (0.5%) Opthalmic Solution\",\"authors\":\"Liena Alagib H Edress, D. Elhag\",\"doi\":\"10.26502/JPPR.0017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Preservative assay in eye drops require the development of a suitable validated method for the assay. Objective: This study was conducted to develop and validate stability indicating High Performance Liquid Chromatography (HPLC) method for assay of benzalonium chloride in betaxolol 0.5% ophthalmic solution. Method: Method was developed validated according to International conference on harmonization (ICH) guideline. Chromatographic condition used was: L10 CN column (250 cm × 4.6 mm × 10 μm); flow rate 2.0 ml per minute; detection wavelength 245 nm; column oven 30°C; mobile phase: (0.1M sodium acetate, acetonitrile) (55:45 v/v) and injection volume 100 μL. Results: The method was found fulfilling the ICH requirement with R2 of 0.9995 for drug, Limit of detection (LOD) of 4.53 μg/ml, and Limit of quantification (LOQ) of 13.75 for benzalkonium chloride. The mean of overall recovery % was found to be 99.96% and the repeatability results was found to be: 99.95% for benzalkonium chloride. The overall intermediate precision results were found to be 100.77%. The method proved to be accurate, precise and specific. Conclusion: The developed method was found to be simple, sensitive and can be used for routine quality control analysis of benzalkonium chloride in betaxolol (0.5%) ophthalmic solutions.\",\"PeriodicalId\":73897,\"journal\":{\"name\":\"Journal of pharmacy and pharmacology research\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of pharmacy and pharmacology research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26502/JPPR.0017\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacy and pharmacology research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26502/JPPR.0017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

背景:眼药水中的防腐剂检测需要开发一种合适的验证方法。目的:建立高效液相色谱法测定0.5%倍他洛尔眼液中苯扎氯铵含量的方法,并对其稳定性进行验证。方法:根据国际协调会议(ICH)指南制定方法并进行验证。色谱条件:L10 CN柱(250 cm × 4.6 mm × 10 μm);流速2.0 ml / min;检测波长245nm;柱式烘箱30℃;流动相:0.1M醋酸钠-乙腈(55:45 v/v),进样量100 μL。结果:该方法符合ICH要求,药物的检测限(LOD)为4.53 μg/ml,苯扎氯铵的定量限(LOQ)为13.75。苯扎氯铵的总回收率平均值为99.96%,重复性为99.95%。总体中间精度结果为100.77%。结果表明,该方法准确、精确、专属性强。结论:该方法简便、灵敏,可用于倍他洛尔(0.5%)眼液中苯扎氯铵的常规质量控制分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development and Validation of Stability Indicating HPLC Method for Benzalkonium Chloride in Betaxolol (0.5%) Opthalmic Solution
Background: Preservative assay in eye drops require the development of a suitable validated method for the assay. Objective: This study was conducted to develop and validate stability indicating High Performance Liquid Chromatography (HPLC) method for assay of benzalonium chloride in betaxolol 0.5% ophthalmic solution. Method: Method was developed validated according to International conference on harmonization (ICH) guideline. Chromatographic condition used was: L10 CN column (250 cm × 4.6 mm × 10 μm); flow rate 2.0 ml per minute; detection wavelength 245 nm; column oven 30°C; mobile phase: (0.1M sodium acetate, acetonitrile) (55:45 v/v) and injection volume 100 μL. Results: The method was found fulfilling the ICH requirement with R2 of 0.9995 for drug, Limit of detection (LOD) of 4.53 μg/ml, and Limit of quantification (LOQ) of 13.75 for benzalkonium chloride. The mean of overall recovery % was found to be 99.96% and the repeatability results was found to be: 99.95% for benzalkonium chloride. The overall intermediate precision results were found to be 100.77%. The method proved to be accurate, precise and specific. Conclusion: The developed method was found to be simple, sensitive and can be used for routine quality control analysis of benzalkonium chloride in betaxolol (0.5%) ophthalmic solutions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A CXCR3-Activating Peptide Increases Tear Break Up Time and Corrects Corneal haze in a Rabbit Model of Environmental Dry Eye. Enhanced Cerebral Hemodynamics and Cognitive Function Via Knockout of Dual-Specificity Protein Phosphatase 5. Impact of Early Palliative Care on End of life in patients with Advanced Biliary Tract Cancer Effects of Fruits of Aqueous Extract of Sarcocephalus Latifolius B. on Gentamicin-Induced Nephrotoxicity in Rats Analgesic, Anti-inflammatory, and Antioxidant potential of S-adenosyl L-Methionine on Nitroglycerine induced Migraine in mice Models
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1