Edwin J. Myers, David S. Dominguez, Melissa E. Guigliano, Melissa G. Mallory
{"title":"BTE技术EVJ手柄与测量握力的Jamar手测力仪的比较","authors":"Edwin J. Myers, David S. Dominguez, Melissa E. Guigliano, Melissa G. Mallory","doi":"10.3233/tad-200318","DOIUrl":null,"url":null,"abstract":"INTRODUCTION: This study compared the inter-instrument reliability of the Jamar Hand Dynamometer (Jamar) to the BTE EVJ Handgrip tool (EVJ). The EVJ is a new digital handgrip instrument designed by BTE Technologies Inc. (BTE Tech) utilizing Bluetooth technology to automatically upload data to a computer or electronic health record. METHOD: This repeated measure study engaged 338 participants (N= 199 females, N= 139 males) ages 20 to 50. All participants were tested on both devices following the protocol established by the American Society of Hand Therapists (ASHT). RESULTS: Comparative statistics included ICC values (0.81–0.84), Pearson R (correlation coefficient) (0.68–0.77), and Bland Altman plots (93–95% of data within 2 SD), indicating good inter-instrument agreement. CONCLUSIONS: The EVJ Handgrip, developed by BTE Technologies, demonstrated good inter-instrument reliability with the Jamar Hand Dynamometer and may be reliable to use when referencing the published normative values in the clinical environment.","PeriodicalId":22201,"journal":{"name":"Technology and Disability","volume":"1 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3233/tad-200318","citationCount":"0","resultStr":"{\"title\":\"Comparison of the BTE tech EVJ handgrip to the Jamar hand dynamometer for measuring grip strength\",\"authors\":\"Edwin J. Myers, David S. Dominguez, Melissa E. Guigliano, Melissa G. Mallory\",\"doi\":\"10.3233/tad-200318\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"INTRODUCTION: This study compared the inter-instrument reliability of the Jamar Hand Dynamometer (Jamar) to the BTE EVJ Handgrip tool (EVJ). The EVJ is a new digital handgrip instrument designed by BTE Technologies Inc. (BTE Tech) utilizing Bluetooth technology to automatically upload data to a computer or electronic health record. METHOD: This repeated measure study engaged 338 participants (N= 199 females, N= 139 males) ages 20 to 50. All participants were tested on both devices following the protocol established by the American Society of Hand Therapists (ASHT). RESULTS: Comparative statistics included ICC values (0.81–0.84), Pearson R (correlation coefficient) (0.68–0.77), and Bland Altman plots (93–95% of data within 2 SD), indicating good inter-instrument agreement. CONCLUSIONS: The EVJ Handgrip, developed by BTE Technologies, demonstrated good inter-instrument reliability with the Jamar Hand Dynamometer and may be reliable to use when referencing the published normative values in the clinical environment.\",\"PeriodicalId\":22201,\"journal\":{\"name\":\"Technology and Disability\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3233/tad-200318\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technology and Disability\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3233/tad-200318\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Disability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/tad-200318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"REHABILITATION","Score":null,"Total":0}
Comparison of the BTE tech EVJ handgrip to the Jamar hand dynamometer for measuring grip strength
INTRODUCTION: This study compared the inter-instrument reliability of the Jamar Hand Dynamometer (Jamar) to the BTE EVJ Handgrip tool (EVJ). The EVJ is a new digital handgrip instrument designed by BTE Technologies Inc. (BTE Tech) utilizing Bluetooth technology to automatically upload data to a computer or electronic health record. METHOD: This repeated measure study engaged 338 participants (N= 199 females, N= 139 males) ages 20 to 50. All participants were tested on both devices following the protocol established by the American Society of Hand Therapists (ASHT). RESULTS: Comparative statistics included ICC values (0.81–0.84), Pearson R (correlation coefficient) (0.68–0.77), and Bland Altman plots (93–95% of data within 2 SD), indicating good inter-instrument agreement. CONCLUSIONS: The EVJ Handgrip, developed by BTE Technologies, demonstrated good inter-instrument reliability with the Jamar Hand Dynamometer and may be reliable to use when referencing the published normative values in the clinical environment.
期刊介绍:
Technology and Disability communicates knowledge about the field of assistive technology devices and services, within the context of the lives of end users - persons with disabilities and their family members. While the topics are technical in nature, the articles are written for broad comprehension despite the reader"s education or training. Technology and Disability"s contents cover research and development efforts, education and training programs, service and policy activities and consumer experiences. - The term Technology refers to assistive devices and services. - The term Disability refers to both permanent and temporary functional limitations experienced by people of any age within any circumstance.