弹性成形术:治疗骨质疏松性椎体压缩性骨折的新技术

F. Villarejo, B. Mansilla, M. Budke
{"title":"弹性成形术:治疗骨质疏松性椎体压缩性骨折的新技术","authors":"F. Villarejo, B. Mansilla, M. Budke","doi":"10.36648/2171-6625.21.10.376","DOIUrl":null,"url":null,"abstract":"Objective: Vertebral compression fractures (VCF) cause significant disability and pain and are usually treated by vertebroplasty using polymethylmethacrylate (PMMA), which has several drawbacks, including fractures and exothermic neural damage associated to lea-kage. VK100 silicone is a new polymer for vertebroplasty to resolve these disadvantages. Material and Methods: This study follows the evolution of seventy patients with VCF who received a VK100 elastoplasty. The period of follow up was a year average. Results: Four patients had asymptomatic silicone leakage, none had neural damage and, at the end of follow up, there had been no adjacent fractures. Patients reported less pain. Conclusion: We conclude VK100 is a good option for vertebroplasty to treat osteoporotic spinal compression fractures.","PeriodicalId":91329,"journal":{"name":"Journal of neurology and neuroscience","volume":"12 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Elastoplasty: A New Technique for Treatment of steoporotic Vertebral Compression Fractures\",\"authors\":\"F. Villarejo, B. Mansilla, M. Budke\",\"doi\":\"10.36648/2171-6625.21.10.376\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: Vertebral compression fractures (VCF) cause significant disability and pain and are usually treated by vertebroplasty using polymethylmethacrylate (PMMA), which has several drawbacks, including fractures and exothermic neural damage associated to lea-kage. VK100 silicone is a new polymer for vertebroplasty to resolve these disadvantages. Material and Methods: This study follows the evolution of seventy patients with VCF who received a VK100 elastoplasty. The period of follow up was a year average. Results: Four patients had asymptomatic silicone leakage, none had neural damage and, at the end of follow up, there had been no adjacent fractures. Patients reported less pain. Conclusion: We conclude VK100 is a good option for vertebroplasty to treat osteoporotic spinal compression fractures.\",\"PeriodicalId\":91329,\"journal\":{\"name\":\"Journal of neurology and neuroscience\",\"volume\":\"12 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neurology and neuroscience\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36648/2171-6625.21.10.376\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurology and neuroscience","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36648/2171-6625.21.10.376","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:椎体压缩性骨折(VCF)会导致严重的残疾和疼痛,通常采用聚甲基丙烯酸甲酯(PMMA)椎体成形术治疗,该方法有几个缺点,包括骨折和放热神经损伤相关的渗漏。VK100硅胶是一种用于椎体成形术的新型聚合物,解决了这些缺点。材料和方法:本研究跟踪了70例接受VK100弹性成形术的VCF患者的进展。随访时间平均为一年。结果:4例患者无症状硅胶渗漏,无神经损伤,随访结束时无相邻骨折。患者报告疼痛减轻。结论:VK100椎体成形术是治疗骨质疏松性脊柱压缩性骨折的良好选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Elastoplasty: A New Technique for Treatment of steoporotic Vertebral Compression Fractures
Objective: Vertebral compression fractures (VCF) cause significant disability and pain and are usually treated by vertebroplasty using polymethylmethacrylate (PMMA), which has several drawbacks, including fractures and exothermic neural damage associated to lea-kage. VK100 silicone is a new polymer for vertebroplasty to resolve these disadvantages. Material and Methods: This study follows the evolution of seventy patients with VCF who received a VK100 elastoplasty. The period of follow up was a year average. Results: Four patients had asymptomatic silicone leakage, none had neural damage and, at the end of follow up, there had been no adjacent fractures. Patients reported less pain. Conclusion: We conclude VK100 is a good option for vertebroplasty to treat osteoporotic spinal compression fractures.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Biopsychosocial Implications of Crystal Methamphetamine Abuse: A Review of Literature Assessing Neural Oscillations during Erotic and Negative Emotional Pictures Viewing: An Event-Related Potential Study Challenges in Diagnosis of Ischaemic Stroke: A Descriptive Study of Stroke Mimics and Missed Strokes Hornerandrsquo;s Syndrome due to a Spontaneous Internal Carotid Artery Dissection treated with Casper Stent The Impact of 24-Hour Ambulatory EEG in the Clinical Approach to Patients with Suspected Epilepsy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1