{"title":"光固化单元特性对牙用树脂复合材料光强输出、固化深度和表面显微硬度的影响。","authors":"B. A. Kassim, B. Kisumbi, W. Lesan, L. Gathece","doi":"10.4314/EAMJ.V90I9","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nModern dental composite restorations are wholly dependent on the use of Visible Light Curing devices. The characteristics of these devices may influence the quality of composite resin restorations.\n\n\nOBJECTIVE\nTo determine the characteristics of light curing units (LCUs) in dental clinics in Nairobi and their effect on light intensity output, depth of cure (DOC) and surface micro-hardness (SMH) of dental resin composite.\n\n\nDESIGN\nLaboratory based, cross-sectional analytical study.\n\n\nSETTING\nPublic and private dental clinics in Nairobi, Kenya.\n\n\nSUBJECTS\nEighty three LCUs which were in use in private and public dental health facilities in Nairobi, Kenya and resin composite specimens.\n\n\nRESULTS\nOf the 83 LCUs studied, 43 (51.8%) were Light Emitting Diodes (LEDs) and 39(47.0%) were Quartz-Tungsten-Halogen (QTH) and 1 (1.2%) was Plasma Arc Curing (PAC) light. Mean light intensity for QTH and LED lights was 526.59 mW/cm2 and 493.67 mW/cm2 respectively (p=0.574), while the mean DOC for QTH lights was 1.71 mm and LED was 1.67 mm (p=0.690). Mean Vickers Hardness Number (VHN) for LED was 57.44 and for QTH was 44.14 (p=0.713). Mean light intensity for LCUs < or = 5 years was 596.03 mW/cm2 and 363.17 mW/cm2 for units > 5 years old (p=0.024). The mean DOC for the two age groups was 1.74 mm and 1.57 mm respectively (p=0.073). For SMH, the < or = 5 years and >5 years age groups gave a mean VHN of 58.81 and 51.46 respectively (p=0.1). On maintenance history, the frequency of routine inspection, duration since the last repair/replacement of a part or other maintenance activity and the nature of the last maintenance activity were determined and were not found to have influenced the light intensity, DOC and SMH.\n\n\nCONCLUSION\nThe LCU age has a statistically significant influence on its light intensity (p=0.024) while the type and maintenance history have no significant influence on its light intensity and composite DOC and SMH (p=0.574, p=0.690, p=0.713 respectively).","PeriodicalId":11399,"journal":{"name":"East African medical journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"EFFECT OF LIGHT CURING UNIT CHARACTERISTICS ON LIGHT INTENSITY OUTPUT, DEPTH OF CURE AND SURFACE MICRO-HARDNESS OF DENTAL RESIN COMPOSITE.\",\"authors\":\"B. A. Kassim, B. Kisumbi, W. Lesan, L. Gathece\",\"doi\":\"10.4314/EAMJ.V90I9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND\\nModern dental composite restorations are wholly dependent on the use of Visible Light Curing devices. The characteristics of these devices may influence the quality of composite resin restorations.\\n\\n\\nOBJECTIVE\\nTo determine the characteristics of light curing units (LCUs) in dental clinics in Nairobi and their effect on light intensity output, depth of cure (DOC) and surface micro-hardness (SMH) of dental resin composite.\\n\\n\\nDESIGN\\nLaboratory based, cross-sectional analytical study.\\n\\n\\nSETTING\\nPublic and private dental clinics in Nairobi, Kenya.\\n\\n\\nSUBJECTS\\nEighty three LCUs which were in use in private and public dental health facilities in Nairobi, Kenya and resin composite specimens.\\n\\n\\nRESULTS\\nOf the 83 LCUs studied, 43 (51.8%) were Light Emitting Diodes (LEDs) and 39(47.0%) were Quartz-Tungsten-Halogen (QTH) and 1 (1.2%) was Plasma Arc Curing (PAC) light. Mean light intensity for QTH and LED lights was 526.59 mW/cm2 and 493.67 mW/cm2 respectively (p=0.574), while the mean DOC for QTH lights was 1.71 mm and LED was 1.67 mm (p=0.690). Mean Vickers Hardness Number (VHN) for LED was 57.44 and for QTH was 44.14 (p=0.713). Mean light intensity for LCUs < or = 5 years was 596.03 mW/cm2 and 363.17 mW/cm2 for units > 5 years old (p=0.024). The mean DOC for the two age groups was 1.74 mm and 1.57 mm respectively (p=0.073). For SMH, the < or = 5 years and >5 years age groups gave a mean VHN of 58.81 and 51.46 respectively (p=0.1). On maintenance history, the frequency of routine inspection, duration since the last repair/replacement of a part or other maintenance activity and the nature of the last maintenance activity were determined and were not found to have influenced the light intensity, DOC and SMH.\\n\\n\\nCONCLUSION\\nThe LCU age has a statistically significant influence on its light intensity (p=0.024) while the type and maintenance history have no significant influence on its light intensity and composite DOC and SMH (p=0.574, p=0.690, p=0.713 respectively).\",\"PeriodicalId\":11399,\"journal\":{\"name\":\"East African medical journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"East African medical journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4314/EAMJ.V90I9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"East African medical journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/EAMJ.V90I9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 4
摘要
现代牙科复合修复完全依赖于可见光固化设备的使用。这些装置的特性可能会影响复合树脂修复体的质量。目的了解内罗毕地区牙科诊所光固化单元(lcu)的特点及其对牙用树脂复合材料光强输出、固化深度(DOC)和表面显微硬度(SMH)的影响。设计实验室为基础,横断面分析研究。肯尼亚内罗毕的公立和私立牙科诊所。受试者:在肯尼亚内罗毕的私人和公共牙科保健机构使用的73个lcu和树脂复合材料标本。结果83个lcu中,发光二极管(led) 43个(51.8%),石英钨卤灯(QTH) 39个(47.0%),等离子弧固化(PAC)灯1个(1.2%)。QTH灯和LED灯的平均光强分别为526.59 mW/cm2和493.67 mW/cm2 (p=0.574), QTH灯和LED灯的平均DOC分别为1.71 mm和1.67 mm (p=0.690)。LED的平均维氏硬度值(VHN)为57.44,QTH为44.14 (p=0.713)。lcu <或= 5年的平均光强为596.03 mW/cm2, bbb50年的平均光强为363.17 mW/cm2 (p=0.024)。两个年龄组的平均DOC分别为1.74 mm和1.57 mm (p=0.073)。对于SMH, < or = 5岁和bb0 = 5岁年龄组的VHN平均值分别为58.81和51.46 (p=0.1)。在维修历史方面,确定了例行检查的频率、自上次维修/更换部件或其他维修活动以来的持续时间以及上次维修活动的性质,但没有发现这些因素影响光照强度、DOC和SMH。结论LCU年龄对其光强的影响有统计学意义(p=0.024),而类型和维护历史对其光强和复合DOC、SMH的影响无统计学意义(p=0.574、p=0.690、p=0.713)。
EFFECT OF LIGHT CURING UNIT CHARACTERISTICS ON LIGHT INTENSITY OUTPUT, DEPTH OF CURE AND SURFACE MICRO-HARDNESS OF DENTAL RESIN COMPOSITE.
BACKGROUND
Modern dental composite restorations are wholly dependent on the use of Visible Light Curing devices. The characteristics of these devices may influence the quality of composite resin restorations.
OBJECTIVE
To determine the characteristics of light curing units (LCUs) in dental clinics in Nairobi and their effect on light intensity output, depth of cure (DOC) and surface micro-hardness (SMH) of dental resin composite.
DESIGN
Laboratory based, cross-sectional analytical study.
SETTING
Public and private dental clinics in Nairobi, Kenya.
SUBJECTS
Eighty three LCUs which were in use in private and public dental health facilities in Nairobi, Kenya and resin composite specimens.
RESULTS
Of the 83 LCUs studied, 43 (51.8%) were Light Emitting Diodes (LEDs) and 39(47.0%) were Quartz-Tungsten-Halogen (QTH) and 1 (1.2%) was Plasma Arc Curing (PAC) light. Mean light intensity for QTH and LED lights was 526.59 mW/cm2 and 493.67 mW/cm2 respectively (p=0.574), while the mean DOC for QTH lights was 1.71 mm and LED was 1.67 mm (p=0.690). Mean Vickers Hardness Number (VHN) for LED was 57.44 and for QTH was 44.14 (p=0.713). Mean light intensity for LCUs < or = 5 years was 596.03 mW/cm2 and 363.17 mW/cm2 for units > 5 years old (p=0.024). The mean DOC for the two age groups was 1.74 mm and 1.57 mm respectively (p=0.073). For SMH, the < or = 5 years and >5 years age groups gave a mean VHN of 58.81 and 51.46 respectively (p=0.1). On maintenance history, the frequency of routine inspection, duration since the last repair/replacement of a part or other maintenance activity and the nature of the last maintenance activity were determined and were not found to have influenced the light intensity, DOC and SMH.
CONCLUSION
The LCU age has a statistically significant influence on its light intensity (p=0.024) while the type and maintenance history have no significant influence on its light intensity and composite DOC and SMH (p=0.574, p=0.690, p=0.713 respectively).
期刊介绍:
The East African Medical Journal is published every month. It is intended for publication of papers on original work and reviews of all aspects of medicine. Communications bearing on clinical and basic research on problems relevant to East Africa and other African countries will receive special attention. Papers submitted for publication are accepted only on the understanding they will not be published elsewhere without the permission of the Editor-in-Chief