静止状态心动过缓患者双传感器心脏起搏器系统的模糊控制

Basil Hamed, A. Ras
{"title":"静止状态心动过缓患者双传感器心脏起搏器系统的模糊控制","authors":"Basil Hamed, A. Ras","doi":"10.4236/ICA.2015.63016","DOIUrl":null,"url":null,"abstract":"Cardiovascular \ndisease is defined as a heart rate that is less than 60 bpm. Implantable \ncardiac devices such as pacemakers are widely used nowadays. In this paper, design and implementation of \nthe heart model can be controlled to be the heart of a patient suffering from a \ndecrease in heart rate (Bradycardia). A system is designed to sense and calculate \nthe heart rate per minute and it is considered as an input to the controller. \nThe design and implementation of Mamdani fuzzy controller to \ngenerate electric pulses that mimic the natural pacing system of the heart \nmaintains an adequate heart rate by delivering controlled, rhythmic electrical \nstimuli to the chambers of the patient heart. The proposed controller is tested by using \nMatlab/Simulink program.","PeriodicalId":62904,"journal":{"name":"智能控制与自动化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Fuzzy Controller for Dual Sensors Cardiac Pacemaker System in Patients with Bradycardias at Rest\",\"authors\":\"Basil Hamed, A. Ras\",\"doi\":\"10.4236/ICA.2015.63016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cardiovascular \\ndisease is defined as a heart rate that is less than 60 bpm. Implantable \\ncardiac devices such as pacemakers are widely used nowadays. In this paper, design and implementation of \\nthe heart model can be controlled to be the heart of a patient suffering from a \\ndecrease in heart rate (Bradycardia). A system is designed to sense and calculate \\nthe heart rate per minute and it is considered as an input to the controller. \\nThe design and implementation of Mamdani fuzzy controller to \\ngenerate electric pulses that mimic the natural pacing system of the heart \\nmaintains an adequate heart rate by delivering controlled, rhythmic electrical \\nstimuli to the chambers of the patient heart. The proposed controller is tested by using \\nMatlab/Simulink program.\",\"PeriodicalId\":62904,\"journal\":{\"name\":\"智能控制与自动化(英文)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"智能控制与自动化(英文)\",\"FirstCategoryId\":\"1093\",\"ListUrlMain\":\"https://doi.org/10.4236/ICA.2015.63016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"智能控制与自动化(英文)","FirstCategoryId":"1093","ListUrlMain":"https://doi.org/10.4236/ICA.2015.63016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

心血管疾病被定义为心率低于每分钟60次。植入式心脏装置,如起搏器,现在被广泛使用。在本文中,心脏模型的设计和实现可以控制为患有心率降低(心动过缓)的患者的心脏。一个系统被设计用来感知和计算每分钟的心率,它被认为是控制器的输入。Mamdani模糊控制器的设计和实现可以产生模拟心脏自然起搏系统的电脉冲,通过向患者心脏腔提供受控的、有节奏的电刺激来保持适当的心率。采用Matlab/Simulink程序对所设计的控制器进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fuzzy Controller for Dual Sensors Cardiac Pacemaker System in Patients with Bradycardias at Rest
Cardiovascular disease is defined as a heart rate that is less than 60 bpm. Implantable cardiac devices such as pacemakers are widely used nowadays. In this paper, design and implementation of the heart model can be controlled to be the heart of a patient suffering from a decrease in heart rate (Bradycardia). A system is designed to sense and calculate the heart rate per minute and it is considered as an input to the controller. The design and implementation of Mamdani fuzzy controller to generate electric pulses that mimic the natural pacing system of the heart maintains an adequate heart rate by delivering controlled, rhythmic electrical stimuli to the chambers of the patient heart. The proposed controller is tested by using Matlab/Simulink program.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
243
期刊最新文献
Maximizing the Efficiency of Automation Solutions with Automation 360: Approaches for Developing Subtasks and Retry Framework Data-Driven Model Identification and Control of the Inertial Systems Using Singular Value to Set Output Disturbance Limits to Feedback ILC Control Blockchain-Based Islamic Marriage Certification with the Supremacy of Web 3.0 Artificial Intelligence Trends and Ethics: Issues and Alternatives for Investors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1