{"title":"2000-2005年期间,Harmattan尘埃在加纳沉积","authors":"T. Awadzi, H. Breuning‐madsen","doi":"10.4314/WAJAE.V11I1.45723","DOIUrl":null,"url":null,"abstract":"Between 2000–2005, a monitoring system for the collection of harmattan dust over Ghana was established. Three methods were used to sample the harmattan dust: i) bowls with water, ii) plastic mats and iii) plates made of plywood. This paper describes the establishment of the monitoring system, and the regional distribution of harmattan dust trapped in various agro-ecological zones by the bowls with water and the mats. The bowl values represent the total amount of dust falling over a unit area, and the mat values represents the amount of dust retained by vegetation. The amount of harmattan dust captured is largest in the north where the mats retained about 20 g/cm3 compared to 5 g/cm3 in the south. The amount of dust retained differs significantly from year to year, and the particle-size of the dust becomes finer towards the south and with an increasing amount of organic matter. In the north, the median diameter was slightly above 15 mm and the organic carbon content was about 5% while in the south the median diameter was slightly above 5 mm and the organic carbon content was between 10 and 15%.","PeriodicalId":39286,"journal":{"name":"West African Journal of Applied Ecology","volume":"11 1","pages":"173-188"},"PeriodicalIF":0.0000,"publicationDate":"2009-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4314/WAJAE.V11I1.45723","citationCount":"10","resultStr":"{\"title\":\"Harmattan dust deposited in Ghana within 2000-2005\",\"authors\":\"T. Awadzi, H. Breuning‐madsen\",\"doi\":\"10.4314/WAJAE.V11I1.45723\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Between 2000–2005, a monitoring system for the collection of harmattan dust over Ghana was established. Three methods were used to sample the harmattan dust: i) bowls with water, ii) plastic mats and iii) plates made of plywood. This paper describes the establishment of the monitoring system, and the regional distribution of harmattan dust trapped in various agro-ecological zones by the bowls with water and the mats. The bowl values represent the total amount of dust falling over a unit area, and the mat values represents the amount of dust retained by vegetation. The amount of harmattan dust captured is largest in the north where the mats retained about 20 g/cm3 compared to 5 g/cm3 in the south. The amount of dust retained differs significantly from year to year, and the particle-size of the dust becomes finer towards the south and with an increasing amount of organic matter. In the north, the median diameter was slightly above 15 mm and the organic carbon content was about 5% while in the south the median diameter was slightly above 5 mm and the organic carbon content was between 10 and 15%.\",\"PeriodicalId\":39286,\"journal\":{\"name\":\"West African Journal of Applied Ecology\",\"volume\":\"11 1\",\"pages\":\"173-188\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4314/WAJAE.V11I1.45723\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"West African Journal of Applied Ecology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4314/WAJAE.V11I1.45723\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"West African Journal of Applied Ecology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/WAJAE.V11I1.45723","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Environmental Science","Score":null,"Total":0}
Harmattan dust deposited in Ghana within 2000-2005
Between 2000–2005, a monitoring system for the collection of harmattan dust over Ghana was established. Three methods were used to sample the harmattan dust: i) bowls with water, ii) plastic mats and iii) plates made of plywood. This paper describes the establishment of the monitoring system, and the regional distribution of harmattan dust trapped in various agro-ecological zones by the bowls with water and the mats. The bowl values represent the total amount of dust falling over a unit area, and the mat values represents the amount of dust retained by vegetation. The amount of harmattan dust captured is largest in the north where the mats retained about 20 g/cm3 compared to 5 g/cm3 in the south. The amount of dust retained differs significantly from year to year, and the particle-size of the dust becomes finer towards the south and with an increasing amount of organic matter. In the north, the median diameter was slightly above 15 mm and the organic carbon content was about 5% while in the south the median diameter was slightly above 5 mm and the organic carbon content was between 10 and 15%.
期刊介绍:
This research journal has been established by the Ecological Laboratory Unit of the University of Ghana, Accra to publish original papers, invited articles and book reviews in English on general ecology. Papers are peer reviewed by consulting editors. The journal is targeted at scientists, policy makers and the general public. The subject areas to be covered include the following: -Theoretical and Applied Ecology- Environmental Studies- Environmental Management- Population Studies- Sustainable use of Natural Resources- Atmospheric Science- Aquatic Sciences and Oceanography- Terrestrial Ecology- Soil Sciences- Human Settlements- Disaster Preparedness and Disaster Reduction- Sustainable Development- Traditional Knowledge on Biodiversity and its sustainable use- Application in Agriculture and Land Use- Health and Environmental Protection