{"title":"电力系统有功和无功功率的充分性评价","authors":"W. Qin, Peng Wang, Xiaoqing Han, Zhijuan Liu","doi":"10.7500/AEPS20130529009","DOIUrl":null,"url":null,"abstract":"Reactive power plays an important role in power system reliability as it is closely related to system voltage stability and voltage collapse.However,the reactive power related reliability issues are seldom emphasized in conventional power reliability evaluation.This paper studies the power system reliability from the perspective of active and reactive power, respectively.Active and reactive power inadequacy and the associated voltage perturbation due to system failure are considered in reliability evaluation of power systems.A three-stage load shedding technique for past contingencies are implemented to determine the influence of active and reactive power on system reliability and to find an optimal way to relieve network violation.","PeriodicalId":52447,"journal":{"name":"电力系统自动化","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Adequacy evaluation of active and reactive power in power systems\",\"authors\":\"W. Qin, Peng Wang, Xiaoqing Han, Zhijuan Liu\",\"doi\":\"10.7500/AEPS20130529009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reactive power plays an important role in power system reliability as it is closely related to system voltage stability and voltage collapse.However,the reactive power related reliability issues are seldom emphasized in conventional power reliability evaluation.This paper studies the power system reliability from the perspective of active and reactive power, respectively.Active and reactive power inadequacy and the associated voltage perturbation due to system failure are considered in reliability evaluation of power systems.A three-stage load shedding technique for past contingencies are implemented to determine the influence of active and reactive power on system reliability and to find an optimal way to relieve network violation.\",\"PeriodicalId\":52447,\"journal\":{\"name\":\"电力系统自动化\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"电力系统自动化\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.7500/AEPS20130529009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"电力系统自动化","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.7500/AEPS20130529009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

无功功率对电力系统的可靠性起着重要的作用,它与系统电压稳定和电压崩溃密切相关。然而,在传统的电力可靠性评估中,与无功有关的可靠性问题很少得到重视。本文分别从有功功率和无功功率的角度对电力系统可靠性进行了研究。电力系统的可靠性评估主要考虑有功功率和无功功率不足以及系统故障引起的电压扰动。为了确定有功功率和无功功率对系统可靠性的影响,找到缓解网络违例的最佳方法,采用了一种针对过去突发事件的三级减载技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Adequacy evaluation of active and reactive power in power systems
Reactive power plays an important role in power system reliability as it is closely related to system voltage stability and voltage collapse.However,the reactive power related reliability issues are seldom emphasized in conventional power reliability evaluation.This paper studies the power system reliability from the perspective of active and reactive power, respectively.Active and reactive power inadequacy and the associated voltage perturbation due to system failure are considered in reliability evaluation of power systems.A three-stage load shedding technique for past contingencies are implemented to determine the influence of active and reactive power on system reliability and to find an optimal way to relieve network violation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
电力系统自动化
电力系统自动化 Energy-Energy Engineering and Power Technology
CiteScore
8.20
自引率
0.00%
发文量
15032
期刊介绍: Founded in 1977, Power System Automation is a well-known journal in the discipline of electrical engineering in China. At present, it has been issued to all provinces, cities, autonomous regions, Hong Kong, Macao and Taiwan, and abroad to dozens of countries in North America, Europe and Asia-Pacific region, with a large number of readers at home and abroad. Power System Automation takes “based on China, facing the world, seeking truth and innovation, promoting scientific and technological progress in the field of electric power and energy” as the purpose of the journal, mainly for the professional and technical personnel, teachers and students engaged in scientific research, design, operation, testing, manufacturing, management and marketing in the electric power industry and higher education institutions as well as electric power users, and focuses on hotspots of the industry's development and the It focuses on the hot and difficult issues of the industry. It focuses on the hot and difficult issues of the industry, both academic and forward-looking, practical and oriented, and at the same time emphasizes and encourages technical exchanges of experiences, improvements and innovations from the front line of scientific research and production.
期刊最新文献
Active Frequency Drift Islanding Detection Technology with Feedback of Load Impedance Angle Coordinated heat and power dispatch of microgrid considering two-dimensional controllability of heat loads Fault tolerance ability analysis and evaluation of three-phase voltage source converters Calculation method of nodal price in distribution network considering power supply reliability A Coordinated Charging Strategy for Electric Vehicle Three-phase Load Balance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1