{"title":"火电厂噪声分布分析及隔声措施","authors":"J. Yun, Won-Jin Kim","doi":"10.7776/ASK.2020.39.2.105","DOIUrl":null,"url":null,"abstract":": An analysis model of noise map is proposed to evaluate and reduce the acoustical noise of power plant and its surroundings. The sound powers of many noise sources are estimated by measuring the sound levels of major equipments in the power plant. The analysis of noise has been made by using ENPro that is a commercial program for environmental noise prediction. The proposed model is verified by comparing the results from noise analysis and measurement at several points of the power plant units 1 through 4, and residential areas. It is shown that noise map simulation using the proposed model has a reliability, since the overall noise level approximates within the error of ±2 dB. Furthermore, through noise analysis, the increasing effect of noise due to newly established units 5 and 6 on residential areas is also analyzed. Consequently, the noise barrier is designed to meet an environmental noise standard and satisfy low cost and safety conditions.","PeriodicalId":42689,"journal":{"name":"Journal of the Acoustical Society of Korea","volume":"39 1","pages":"105-112"},"PeriodicalIF":0.2000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Noise distribution analysis and noise barrier measures of thermal power plant\",\"authors\":\"J. Yun, Won-Jin Kim\",\"doi\":\"10.7776/ASK.2020.39.2.105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": An analysis model of noise map is proposed to evaluate and reduce the acoustical noise of power plant and its surroundings. The sound powers of many noise sources are estimated by measuring the sound levels of major equipments in the power plant. The analysis of noise has been made by using ENPro that is a commercial program for environmental noise prediction. The proposed model is verified by comparing the results from noise analysis and measurement at several points of the power plant units 1 through 4, and residential areas. It is shown that noise map simulation using the proposed model has a reliability, since the overall noise level approximates within the error of ±2 dB. Furthermore, through noise analysis, the increasing effect of noise due to newly established units 5 and 6 on residential areas is also analyzed. Consequently, the noise barrier is designed to meet an environmental noise standard and satisfy low cost and safety conditions.\",\"PeriodicalId\":42689,\"journal\":{\"name\":\"Journal of the Acoustical Society of Korea\",\"volume\":\"39 1\",\"pages\":\"105-112\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Acoustical Society of Korea\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7776/ASK.2020.39.2.105\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Acoustical Society of Korea","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7776/ASK.2020.39.2.105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ACOUSTICS","Score":null,"Total":0}
Noise distribution analysis and noise barrier measures of thermal power plant
: An analysis model of noise map is proposed to evaluate and reduce the acoustical noise of power plant and its surroundings. The sound powers of many noise sources are estimated by measuring the sound levels of major equipments in the power plant. The analysis of noise has been made by using ENPro that is a commercial program for environmental noise prediction. The proposed model is verified by comparing the results from noise analysis and measurement at several points of the power plant units 1 through 4, and residential areas. It is shown that noise map simulation using the proposed model has a reliability, since the overall noise level approximates within the error of ±2 dB. Furthermore, through noise analysis, the increasing effect of noise due to newly established units 5 and 6 on residential areas is also analyzed. Consequently, the noise barrier is designed to meet an environmental noise standard and satisfy low cost and safety conditions.