Stefano Marcia, Joshua Adam Hirsch, Matteo Bellini, Luigi Manfré, Salvatore Masala, Chiara Zini
{"title":"一种新型经皮棘突间装置的经皮取出和更换。","authors":"Stefano Marcia, Joshua Adam Hirsch, Matteo Bellini, Luigi Manfré, Salvatore Masala, Chiara Zini","doi":"10.1177/19714009231212366","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> The aim of this study is to explain the technique used for removing and replacing a novel percutaneous interspinous device (PID).<b>Procedure:</b> Three male patients, with a mean age of 66 years (range 62-72), were included in the study due to displacement (<i>N</i> = 2) or misplacement (<i>N</i> = 1) of the novel PID. This occurred after a mean of 23.3 ± 10.5 days from the initial placement (range 13-34) at the L4-L5 level (<i>N</i> = 1) and L3-L4 level (<i>N</i> = 2). Following the removal of the PID, four new devices were implanted.<b>Conclusion:</b> The novel PID can be safely removed either immediately after its placement during the procedure or after a certain period of days or months from its implantation. The removal procedure can be performed percutaneously under imaging guidance, by closing the four retractable wings, using the same instrumentation as utilized during the initial implantation.</p>","PeriodicalId":47358,"journal":{"name":"Neuroradiology Journal","volume":" ","pages":"645-648"},"PeriodicalIF":1.3000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11444319/pdf/","citationCount":"0","resultStr":"{\"title\":\"Percutaneous removal and replacement of a novel percutaneous interspinous device.\",\"authors\":\"Stefano Marcia, Joshua Adam Hirsch, Matteo Bellini, Luigi Manfré, Salvatore Masala, Chiara Zini\",\"doi\":\"10.1177/19714009231212366\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> The aim of this study is to explain the technique used for removing and replacing a novel percutaneous interspinous device (PID).<b>Procedure:</b> Three male patients, with a mean age of 66 years (range 62-72), were included in the study due to displacement (<i>N</i> = 2) or misplacement (<i>N</i> = 1) of the novel PID. This occurred after a mean of 23.3 ± 10.5 days from the initial placement (range 13-34) at the L4-L5 level (<i>N</i> = 1) and L3-L4 level (<i>N</i> = 2). Following the removal of the PID, four new devices were implanted.<b>Conclusion:</b> The novel PID can be safely removed either immediately after its placement during the procedure or after a certain period of days or months from its implantation. The removal procedure can be performed percutaneously under imaging guidance, by closing the four retractable wings, using the same instrumentation as utilized during the initial implantation.</p>\",\"PeriodicalId\":47358,\"journal\":{\"name\":\"Neuroradiology Journal\",\"volume\":\" \",\"pages\":\"645-648\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11444319/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neuroradiology Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/19714009231212366\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"NEUROIMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neuroradiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19714009231212366","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/3 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"NEUROIMAGING","Score":null,"Total":0}
Percutaneous removal and replacement of a novel percutaneous interspinous device.
Objective: The aim of this study is to explain the technique used for removing and replacing a novel percutaneous interspinous device (PID).Procedure: Three male patients, with a mean age of 66 years (range 62-72), were included in the study due to displacement (N = 2) or misplacement (N = 1) of the novel PID. This occurred after a mean of 23.3 ± 10.5 days from the initial placement (range 13-34) at the L4-L5 level (N = 1) and L3-L4 level (N = 2). Following the removal of the PID, four new devices were implanted.Conclusion: The novel PID can be safely removed either immediately after its placement during the procedure or after a certain period of days or months from its implantation. The removal procedure can be performed percutaneously under imaging guidance, by closing the four retractable wings, using the same instrumentation as utilized during the initial implantation.
期刊介绍:
NRJ - The Neuroradiology Journal (formerly Rivista di Neuroradiologia) is the official journal of the Italian Association of Neuroradiology and of the several Scientific Societies from all over the world. Founded in 1988 as Rivista di Neuroradiologia, of June 2006 evolved in NRJ - The Neuroradiology Journal. It is published bimonthly.