在猪的战术战斗伤亡护理模拟中,一种改良的基于链的海绵敷料控制交界处出血。

IF 3 2区 医学 Q1 EMERGENCY MEDICINE Scandinavian Journal of Trauma Resuscitation & Emergency Medicine Pub Date : 2023-11-09 DOI:10.1186/s13049-023-01133-6
Weihang Wu, Wangwu Liu, Nan Lin, Hu Zhao, Jin Yang, Zhi Ye, Weijin Yang, Yu Wang, Yongchao Fang
{"title":"在猪的战术战斗伤亡护理模拟中,一种改良的基于链的海绵敷料控制交界处出血。","authors":"Weihang Wu, Wangwu Liu, Nan Lin, Hu Zhao, Jin Yang, Zhi Ye, Weijin Yang, Yu Wang, Yongchao Fang","doi":"10.1186/s13049-023-01133-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hemorrhage has always been the focus of battlefield and pre-hospitalization treatment. With the increasing fatality rates associated with junctional bleeding, treatment of bleeding at junctional sites has gradually gained attention in battlefield trauma emergency care. We designed a modified chain-based sponge dressing with a medical polyvinyl alcohol sponge that can be used to treat junctional hemorrhage and tested its hemostatic efficacy and biocompatibility.</p><p><strong>Methods: </strong>Twenty adult Bama miniature pigs were randomly divided into the modified chain-based sponge dressing (MCSD) and standard gauze (SG) groups. The right femoral artery of the pigs was shot at after anesthesia. The Bama miniature pigs were moved to the safety zone immediately to assess the condition according to the MARCH strategy, which evaluates massive hemorrhaging, airway obstruction, respiratory status, circulatory status, head injury & hypothermia. Hemoglobin and coagulation status were checked during the experiment.Among the pigs in which the inguinal hemorrhagic model based on bullet penetrating wounds was successfully established, those in the MCSD group received a disinfected MCSD for hemostasis, while those in the SG group received standard gauze in an imbricate manner to pack the bullet exit and entrance wounds to stop bleeding until the wound was filled, followed by compression for 3 min at sufficient pressure. CT scanning, transmission electron microscopy, and HE staining were conducted after experiment.</p><p><strong>Results: </strong>The MCSD group showed lower hemostasis time and blood loss than the gauze group. The MCSD group also showed a higher success rate of treatment,more stable vital signs and hemoglobin level. The CT scanning results showed tighter packing without large gaps in the MCSD group. The histopathological assessments and the transmission electron microscopy and HE staining findings indicated good biocompatibility of the polyvinyl alcohol sponge.</p><p><strong>Conclusion: </strong>The MCSD met the battlefield's requirements of speedy hemostasis and biosafety for junctional hemorrhage in Bama miniature pigs. Moreover, in comparison with the conventional approach for hemostasis, it showed more stable performance for deep wound hemostasis. These findings provide the theoretical and experimental basis for the application of MCSD in the treatment of hemorrhage in the battlefield in the future.</p>","PeriodicalId":49292,"journal":{"name":"Scandinavian Journal of Trauma Resuscitation & Emergency Medicine","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2023-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10636963/pdf/","citationCount":"0","resultStr":"{\"title\":\"A modified chain-based sponge dressing controls junctional hemorrhage in the tactical combat casualty care simulation of pigs.\",\"authors\":\"Weihang Wu, Wangwu Liu, Nan Lin, Hu Zhao, Jin Yang, Zhi Ye, Weijin Yang, Yu Wang, Yongchao Fang\",\"doi\":\"10.1186/s13049-023-01133-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Hemorrhage has always been the focus of battlefield and pre-hospitalization treatment. With the increasing fatality rates associated with junctional bleeding, treatment of bleeding at junctional sites has gradually gained attention in battlefield trauma emergency care. We designed a modified chain-based sponge dressing with a medical polyvinyl alcohol sponge that can be used to treat junctional hemorrhage and tested its hemostatic efficacy and biocompatibility.</p><p><strong>Methods: </strong>Twenty adult Bama miniature pigs were randomly divided into the modified chain-based sponge dressing (MCSD) and standard gauze (SG) groups. The right femoral artery of the pigs was shot at after anesthesia. The Bama miniature pigs were moved to the safety zone immediately to assess the condition according to the MARCH strategy, which evaluates massive hemorrhaging, airway obstruction, respiratory status, circulatory status, head injury & hypothermia. Hemoglobin and coagulation status were checked during the experiment.Among the pigs in which the inguinal hemorrhagic model based on bullet penetrating wounds was successfully established, those in the MCSD group received a disinfected MCSD for hemostasis, while those in the SG group received standard gauze in an imbricate manner to pack the bullet exit and entrance wounds to stop bleeding until the wound was filled, followed by compression for 3 min at sufficient pressure. CT scanning, transmission electron microscopy, and HE staining were conducted after experiment.</p><p><strong>Results: </strong>The MCSD group showed lower hemostasis time and blood loss than the gauze group. The MCSD group also showed a higher success rate of treatment,more stable vital signs and hemoglobin level. The CT scanning results showed tighter packing without large gaps in the MCSD group. The histopathological assessments and the transmission electron microscopy and HE staining findings indicated good biocompatibility of the polyvinyl alcohol sponge.</p><p><strong>Conclusion: </strong>The MCSD met the battlefield's requirements of speedy hemostasis and biosafety for junctional hemorrhage in Bama miniature pigs. Moreover, in comparison with the conventional approach for hemostasis, it showed more stable performance for deep wound hemostasis. These findings provide the theoretical and experimental basis for the application of MCSD in the treatment of hemorrhage in the battlefield in the future.</p>\",\"PeriodicalId\":49292,\"journal\":{\"name\":\"Scandinavian Journal of Trauma Resuscitation & Emergency Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2023-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10636963/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian Journal of Trauma Resuscitation & Emergency Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s13049-023-01133-6\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"EMERGENCY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Trauma Resuscitation & Emergency Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13049-023-01133-6","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:出血一直是战场和住院前治疗的重点。随着交界处出血致死率的不断上升,交界处出血的治疗逐渐引起战场创伤急救的重视。我们用医用聚乙烯醇海绵设计了一种可用于治疗交界处出血的改良链基海绵敷料,并测试了其止血效果和生物相容性。方法:将20头成年巴马小型猪随机分为改良链基海绵敷料(MCSD)组和标准纱布(SG)组。麻醉后对猪的右股动脉进行注射。巴马小型猪被立即转移到安全区,根据MARCH策略评估情况,该策略评估大出血、气道阻塞、呼吸状态、循环状态、头部损伤和体温过低。在实验期间检查血红蛋白和凝血状态。在成功建立基于子弹穿透伤口的腹股沟出血模型的猪中,MCSD组接受消毒的MCSD止血,SG组接受标准纱布叠瓦状包裹子弹出入口伤口止血,直到伤口充满,然后在足够的压力下压缩3分钟。实验后进行CT扫描、透射电镜和HE染色。结果:MCSD组止血时间和出血量均低于纱布组。MCSD组的治疗成功率更高,生命体征和血红蛋白水平更稳定。CT扫描结果显示MCSD组填塞较紧,无大间隙。组织病理学评估、透射电子显微镜和HE染色结果表明聚乙烯醇海绵具有良好的生物相容性。结论:MCSD能满足巴马小型猪交界处出血快速止血和生物安全的战场要求。此外,与传统的止血方法相比,它在深部伤口止血方面表现出更稳定的性能。这些发现为MCSD在未来战场出血治疗中的应用提供了理论和实验依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A modified chain-based sponge dressing controls junctional hemorrhage in the tactical combat casualty care simulation of pigs.

Background: Hemorrhage has always been the focus of battlefield and pre-hospitalization treatment. With the increasing fatality rates associated with junctional bleeding, treatment of bleeding at junctional sites has gradually gained attention in battlefield trauma emergency care. We designed a modified chain-based sponge dressing with a medical polyvinyl alcohol sponge that can be used to treat junctional hemorrhage and tested its hemostatic efficacy and biocompatibility.

Methods: Twenty adult Bama miniature pigs were randomly divided into the modified chain-based sponge dressing (MCSD) and standard gauze (SG) groups. The right femoral artery of the pigs was shot at after anesthesia. The Bama miniature pigs were moved to the safety zone immediately to assess the condition according to the MARCH strategy, which evaluates massive hemorrhaging, airway obstruction, respiratory status, circulatory status, head injury & hypothermia. Hemoglobin and coagulation status were checked during the experiment.Among the pigs in which the inguinal hemorrhagic model based on bullet penetrating wounds was successfully established, those in the MCSD group received a disinfected MCSD for hemostasis, while those in the SG group received standard gauze in an imbricate manner to pack the bullet exit and entrance wounds to stop bleeding until the wound was filled, followed by compression for 3 min at sufficient pressure. CT scanning, transmission electron microscopy, and HE staining were conducted after experiment.

Results: The MCSD group showed lower hemostasis time and blood loss than the gauze group. The MCSD group also showed a higher success rate of treatment,more stable vital signs and hemoglobin level. The CT scanning results showed tighter packing without large gaps in the MCSD group. The histopathological assessments and the transmission electron microscopy and HE staining findings indicated good biocompatibility of the polyvinyl alcohol sponge.

Conclusion: The MCSD met the battlefield's requirements of speedy hemostasis and biosafety for junctional hemorrhage in Bama miniature pigs. Moreover, in comparison with the conventional approach for hemostasis, it showed more stable performance for deep wound hemostasis. These findings provide the theoretical and experimental basis for the application of MCSD in the treatment of hemorrhage in the battlefield in the future.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.10
自引率
6.10%
发文量
57
审稿时长
6-12 weeks
期刊介绍: The primary topics of interest in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine (SJTREM) are the pre-hospital and early in-hospital diagnostic and therapeutic aspects of emergency medicine, trauma, and resuscitation. Contributions focusing on dispatch, major incidents, etiology, pathophysiology, rehabilitation, epidemiology, prevention, education, training, implementation, work environment, as well as ethical and socio-economic aspects may also be assessed for publication.
期刊最新文献
Racing against time: Emergency ambulance dispatches and response times, a register-based study in Region Zealand, Denmark, 2013-2022. Low-energy, high risk: unveiling the undertriage crisis in geriatric trauma. Pre-hospital care for children: a descriptive study from Central Norway. Outcomes of odontoid fractures with associated cardiac arrest: retrospective bi-center case series and systematic literature review. Simulating the methodological bias in the ATLS classification of hypovolemic shock: a critical reappraisal of the base deficit renaissance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1