支撑液膜流动注射分光光度法测定固体和浆状咖啡及茶样品中的咖啡因

E Luque-Pérez , A Rı́os , M Valcárcel , L.-G Danielsson , F Ingman
{"title":"支撑液膜流动注射分光光度法测定固体和浆状咖啡及茶样品中的咖啡因","authors":"E Luque-Pérez ,&nbsp;A Rı́os ,&nbsp;M Valcárcel ,&nbsp;L.-G Danielsson ,&nbsp;F Ingman","doi":"10.1016/S1381-141X(99)00015-5","DOIUrl":null,"url":null,"abstract":"<div><p>A method for the determination of caffeine in coffee and tea samples based on the use of supported liquid membranes coupled to a flow system has been developed. The sample may be analysed both as solid and slurry. In the case of solid sample, this is directly placed in the membrane unit, and when the sample is slurry, this is continuously pumped to the membrane unit. In both cases, the caffeine released from the sample passes through the membrane (PTFE/<em>n</em>-undecane:hexyl ether) into an acidic acceptor stream. This stream flows through a spectrophotometric detector allowing the measurement of the absorbance of caffeine at 274 nm. The method shows a linear range between 0.5 and 15 g l<sup>−1</sup>, with a relative standard deviation of ±3.7% and a sample throughput of 7–8 samples h<sup>−1</sup>.</p></div>","PeriodicalId":100862,"journal":{"name":"Laboratory Automation & Information Management","volume":"34 2","pages":"Pages 131-142"},"PeriodicalIF":0.0000,"publicationDate":"1999-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1381-141X(99)00015-5","citationCount":"18","resultStr":"{\"title\":\"Spectrophotometric flow injection determination of caffeine in solid and slurry coffee and tea samples using supported liquid membranes\",\"authors\":\"E Luque-Pérez ,&nbsp;A Rı́os ,&nbsp;M Valcárcel ,&nbsp;L.-G Danielsson ,&nbsp;F Ingman\",\"doi\":\"10.1016/S1381-141X(99)00015-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A method for the determination of caffeine in coffee and tea samples based on the use of supported liquid membranes coupled to a flow system has been developed. The sample may be analysed both as solid and slurry. In the case of solid sample, this is directly placed in the membrane unit, and when the sample is slurry, this is continuously pumped to the membrane unit. In both cases, the caffeine released from the sample passes through the membrane (PTFE/<em>n</em>-undecane:hexyl ether) into an acidic acceptor stream. This stream flows through a spectrophotometric detector allowing the measurement of the absorbance of caffeine at 274 nm. The method shows a linear range between 0.5 and 15 g l<sup>−1</sup>, with a relative standard deviation of ±3.7% and a sample throughput of 7–8 samples h<sup>−1</sup>.</p></div>\",\"PeriodicalId\":100862,\"journal\":{\"name\":\"Laboratory Automation & Information Management\",\"volume\":\"34 2\",\"pages\":\"Pages 131-142\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S1381-141X(99)00015-5\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laboratory Automation & Information Management\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1381141X99000155\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Automation & Information Management","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1381141X99000155","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

基于与流动系统耦合的支撑液膜的使用,已经开发了一种测定咖啡和茶样品中咖啡因的方法。样品可以作为固体和浆料进行分析。在固体样品的情况下,将其直接放置在膜单元中,当样品为浆料时,将其连续泵送至膜单元。在这两种情况下,从样品中释放的咖啡因通过膜(PTFE/n-十一烷:己基醚)进入酸性受体流。该流流过分光光度检测器,从而能够测量咖啡因在274nm处的吸光度。该方法的线性范围在0.5和15 g l−1之间,相对标准偏差为±3.7%,样品吞吐量为7-8个样品h−1。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Spectrophotometric flow injection determination of caffeine in solid and slurry coffee and tea samples using supported liquid membranes

A method for the determination of caffeine in coffee and tea samples based on the use of supported liquid membranes coupled to a flow system has been developed. The sample may be analysed both as solid and slurry. In the case of solid sample, this is directly placed in the membrane unit, and when the sample is slurry, this is continuously pumped to the membrane unit. In both cases, the caffeine released from the sample passes through the membrane (PTFE/n-undecane:hexyl ether) into an acidic acceptor stream. This stream flows through a spectrophotometric detector allowing the measurement of the absorbance of caffeine at 274 nm. The method shows a linear range between 0.5 and 15 g l−1, with a relative standard deviation of ±3.7% and a sample throughput of 7–8 samples h−1.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Preface Publisher's note Data acquisition, analysis and processing Optimization of laboratory experiments Author index volume 34
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1