食品包装密封缺陷的高对比度图像

C. H. Frazier, A. Ozguler, S. A. Morris, W. O’Brien
{"title":"食品包装密封缺陷的高对比度图像","authors":"C. H. Frazier, A. Ozguler, S. A. Morris, W. O’Brien","doi":"10.1109/ULTSYM.1997.663099","DOIUrl":null,"url":null,"abstract":"Previous work to detect channels in packaging seals using pulse-echo ultrasound inspired the backscattered amplitude integral (BAI) imaging technique, which could reliably identify channels with diameters larger than 15 /spl mu/m at a center frequency of 17.3 MHz (/spl lambda/=86 /spl mu/m). However smaller channels (/spl ap/6 /spl mu/m in diameter) can be easily revealed by processing the data according to a new imaging technique that displays a single time-gated pressure value from the received (not envelope-detected) rf waveform at each transducer position, that is, an rf sample image (RFS). The applicability of this technique for detecting channel defects is demonstrated for plastic and aluminum foil trilaminate films with 6, 10, 15, 38, 50, 75, and 100 /spl mu/m channels filled with water or air. The images are formed with a focused ultrasound transducer (17.3 MHz, 6.35 mm in diameter, f/2, 173 /spl mu/m -6 dB pulse-echo lateral beamwidth at the focus) scanned over a rectangular grid, keeping the package in the focus. Subwavelength channel defects as small as 6 /spl mu/m can be easily detected but appear larger than 150 /spl mu/m wide, according to the focal point size of the transducer. The time-gate used to create an image is chosen based on where the maximum reflection from the back surface of the material is expected. Images created with the RFS technique demonstrate higher contrast than images formed using the BAI or ultrathin C-mode (UTC) techniques. However, RFS imaging also has higher probability of not detecting a channel that is present.","PeriodicalId":6369,"journal":{"name":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1997-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"High contrast images of defects in food package seals\",\"authors\":\"C. H. Frazier, A. Ozguler, S. A. Morris, W. O’Brien\",\"doi\":\"10.1109/ULTSYM.1997.663099\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Previous work to detect channels in packaging seals using pulse-echo ultrasound inspired the backscattered amplitude integral (BAI) imaging technique, which could reliably identify channels with diameters larger than 15 /spl mu/m at a center frequency of 17.3 MHz (/spl lambda/=86 /spl mu/m). However smaller channels (/spl ap/6 /spl mu/m in diameter) can be easily revealed by processing the data according to a new imaging technique that displays a single time-gated pressure value from the received (not envelope-detected) rf waveform at each transducer position, that is, an rf sample image (RFS). The applicability of this technique for detecting channel defects is demonstrated for plastic and aluminum foil trilaminate films with 6, 10, 15, 38, 50, 75, and 100 /spl mu/m channels filled with water or air. The images are formed with a focused ultrasound transducer (17.3 MHz, 6.35 mm in diameter, f/2, 173 /spl mu/m -6 dB pulse-echo lateral beamwidth at the focus) scanned over a rectangular grid, keeping the package in the focus. Subwavelength channel defects as small as 6 /spl mu/m can be easily detected but appear larger than 150 /spl mu/m wide, according to the focal point size of the transducer. The time-gate used to create an image is chosen based on where the maximum reflection from the back surface of the material is expected. Images created with the RFS technique demonstrate higher contrast than images formed using the BAI or ultrathin C-mode (UTC) techniques. However, RFS imaging also has higher probability of not detecting a channel that is present.\",\"PeriodicalId\":6369,\"journal\":{\"name\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1997.663099\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1997.663099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

先前使用脉冲回波超声检测封装密封通道的工作启发了反向散射振幅积分(BAI)成像技术,该技术可以在17.3 MHz (/spl lambda/=86 /spl mu/m)的中心频率下可靠地识别直径大于15 /spl mu/m的通道。然而,通过根据一种新的成像技术处理数据,可以很容易地显示较小的通道(/spl ap/6 /spl mu/m直径),该技术显示每个换能器位置接收(非信封检测)rf波形的单个时间门控压力值,即rf样本图像(RFS)。该技术用于检测通道缺陷的适用性证明了塑料和铝箔三聚氰胺薄膜的6、10、15、38、50、75和100 /spl μ l /m充满水或空气的通道。图像是用聚焦超声换能器(17.3 MHz,直径6.35 mm, f/2, 173 /spl mu/m - 6db脉冲回波横向波束宽度)扫描矩形网格形成的,使封装保持在焦点上。根据换能器的焦点大小,可以很容易地检测到小至6 /spl mu/m的亚波长通道缺陷,但宽度会大于150 /spl mu/m。用于创建图像的时间门是根据预期材料背面的最大反射来选择的。使用RFS技术创建的图像比使用BAI或超薄c模式(UTC)技术形成的图像具有更高的对比度。然而,RFS成像也有更高的概率没有检测到存在的通道。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High contrast images of defects in food package seals
Previous work to detect channels in packaging seals using pulse-echo ultrasound inspired the backscattered amplitude integral (BAI) imaging technique, which could reliably identify channels with diameters larger than 15 /spl mu/m at a center frequency of 17.3 MHz (/spl lambda/=86 /spl mu/m). However smaller channels (/spl ap/6 /spl mu/m in diameter) can be easily revealed by processing the data according to a new imaging technique that displays a single time-gated pressure value from the received (not envelope-detected) rf waveform at each transducer position, that is, an rf sample image (RFS). The applicability of this technique for detecting channel defects is demonstrated for plastic and aluminum foil trilaminate films with 6, 10, 15, 38, 50, 75, and 100 /spl mu/m channels filled with water or air. The images are formed with a focused ultrasound transducer (17.3 MHz, 6.35 mm in diameter, f/2, 173 /spl mu/m -6 dB pulse-echo lateral beamwidth at the focus) scanned over a rectangular grid, keeping the package in the focus. Subwavelength channel defects as small as 6 /spl mu/m can be easily detected but appear larger than 150 /spl mu/m wide, according to the focal point size of the transducer. The time-gate used to create an image is chosen based on where the maximum reflection from the back surface of the material is expected. Images created with the RFS technique demonstrate higher contrast than images formed using the BAI or ultrathin C-mode (UTC) techniques. However, RFS imaging also has higher probability of not detecting a channel that is present.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diamond wafer for SAW application High contrast images of defects in food package seals New properties of the SAW gas sensing Electromagnetic acoustic resonance for studying dislocation formation in polycrystalline pure copper during deformation A new design of ultrasonic air-coupled ribbon transducer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1