Ijaz Ahmad, Meng Huang, Hafiz Muhammad Rukham, Mian Muhammad Kamal
{"title":"TCR设计使三相电弧炉的电压波动在5%以内","authors":"Ijaz Ahmad, Meng Huang, Hafiz Muhammad Rukham, Mian Muhammad Kamal","doi":"10.1109/ICPCSI.2017.8392295","DOIUrl":null,"url":null,"abstract":"Electric Arc Furnaces (EAFs) are unbalanced nonlinear and time varying loads, which can cause many problems in the power system quality. Then by considering the high changes of reactive power and volts flicker of nonlinear heater load, thyristor manipulated reactor compensation with thyristor switched capacitor (TCR) are made and simulated.","PeriodicalId":6589,"journal":{"name":"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)","volume":"2 1","pages":"3096-3099"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"TCR designing to minimize the voltage fluctuation within 5% of three phase arc furnace\",\"authors\":\"Ijaz Ahmad, Meng Huang, Hafiz Muhammad Rukham, Mian Muhammad Kamal\",\"doi\":\"10.1109/ICPCSI.2017.8392295\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electric Arc Furnaces (EAFs) are unbalanced nonlinear and time varying loads, which can cause many problems in the power system quality. Then by considering the high changes of reactive power and volts flicker of nonlinear heater load, thyristor manipulated reactor compensation with thyristor switched capacitor (TCR) are made and simulated.\",\"PeriodicalId\":6589,\"journal\":{\"name\":\"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)\",\"volume\":\"2 1\",\"pages\":\"3096-3099\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPCSI.2017.8392295\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPCSI.2017.8392295","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
TCR designing to minimize the voltage fluctuation within 5% of three phase arc furnace
Electric Arc Furnaces (EAFs) are unbalanced nonlinear and time varying loads, which can cause many problems in the power system quality. Then by considering the high changes of reactive power and volts flicker of nonlinear heater load, thyristor manipulated reactor compensation with thyristor switched capacitor (TCR) are made and simulated.