{"title":"眼和多焦隐形眼镜引起的像差对视觉表现的综合影响:中心距离与中心近距离设计","authors":"D. Lopes-Ferreira, P. Fernandes, A. Queirós, J. González-Méijome","doi":"10.1097/ICL.0000000000000355","DOIUrl":null,"url":null,"abstract":"Purpose: To evaluate the combined effects of inherent ocular aberrations and induced aberrations with a multifocal soft contact lens (MFCL) after 15 days of lens wear in presbyopic participants and their influence on visual performance at distance and near under high and low contrast conditions. Methods: Forty presbyopic participants (mean age, 48.7±3.4) presenting a mean addition of 1.53±0.58 D were fitted with Biofinity Multifocal (CooperVision) and included in the study. Measurements comprised distance and near monocular high (100%) and low contrast (10%) logMAR visual acuity (VA). Ocular aberrations were obtained with Hartmann–Shack aberrometer (IRX3, Imagine Eyes) and analyzed for 2 mm and maximum round natural pupil. Results: Distance VA was significantly higher in dominant eye, whereas near VA was significantly better in the non-dominant eye (P<0.05 in all conditions). For a 2-mm pupil in the dominant eye fitted with MFCL, spherical-like aberration significantly increased (P=0.027) so as higher-order aberrations (HOA) (P=0.002). A significant increase was also observed in spherical-like aberrations (P=0.001), coma-like aberrations (P=0.006) and HOA (P=0.004) in non-dominant eye. For the maximum round natural pupil size, a significant decrease in vertical coma was observed (P=0.018) in dominant eye, whereas a significant increase in spherical-like (P<0.001) and coma-like aberrations (P=0.007) was observed in non-dominant eye. A negative significant correlation was found between vertical coma and high contrast VA (Rho=−0.405, P=0.011) in dominant eye; whereas in non-dominant eye, a significant correlation was found between induced secondary astigmatism and distance VA under high (Rho=0.556, P<0.001) and low contrast (Rho=0.448, P=0.005). Conclusions: On-eye visual performance of MFSCL is dependent on the high-order aberrations induced by dominant and non-dominant design coupled with the wearer's inherent aberrations.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"147 1","pages":"S131–S137"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Combined Effect of Ocular and Multifocal Contact Lens Induced Aberrations on Visual Performance: Center-Distance Versus Center-Near Design\",\"authors\":\"D. Lopes-Ferreira, P. Fernandes, A. Queirós, J. González-Méijome\",\"doi\":\"10.1097/ICL.0000000000000355\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: To evaluate the combined effects of inherent ocular aberrations and induced aberrations with a multifocal soft contact lens (MFCL) after 15 days of lens wear in presbyopic participants and their influence on visual performance at distance and near under high and low contrast conditions. Methods: Forty presbyopic participants (mean age, 48.7±3.4) presenting a mean addition of 1.53±0.58 D were fitted with Biofinity Multifocal (CooperVision) and included in the study. Measurements comprised distance and near monocular high (100%) and low contrast (10%) logMAR visual acuity (VA). Ocular aberrations were obtained with Hartmann–Shack aberrometer (IRX3, Imagine Eyes) and analyzed for 2 mm and maximum round natural pupil. Results: Distance VA was significantly higher in dominant eye, whereas near VA was significantly better in the non-dominant eye (P<0.05 in all conditions). For a 2-mm pupil in the dominant eye fitted with MFCL, spherical-like aberration significantly increased (P=0.027) so as higher-order aberrations (HOA) (P=0.002). A significant increase was also observed in spherical-like aberrations (P=0.001), coma-like aberrations (P=0.006) and HOA (P=0.004) in non-dominant eye. For the maximum round natural pupil size, a significant decrease in vertical coma was observed (P=0.018) in dominant eye, whereas a significant increase in spherical-like (P<0.001) and coma-like aberrations (P=0.007) was observed in non-dominant eye. A negative significant correlation was found between vertical coma and high contrast VA (Rho=−0.405, P=0.011) in dominant eye; whereas in non-dominant eye, a significant correlation was found between induced secondary astigmatism and distance VA under high (Rho=0.556, P<0.001) and low contrast (Rho=0.448, P=0.005). Conclusions: On-eye visual performance of MFSCL is dependent on the high-order aberrations induced by dominant and non-dominant design coupled with the wearer's inherent aberrations.\",\"PeriodicalId\":12216,\"journal\":{\"name\":\"Eye & Contact Lens: Science & Clinical Practice\",\"volume\":\"147 1\",\"pages\":\"S131–S137\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye & Contact Lens: Science & Clinical Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/ICL.0000000000000355\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens: Science & Clinical Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000000355","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

目的:评价老花眼受试者在高、低对比度条件下配戴多焦软性接触镜(MFCL) 15天后固有眼像差和诱发性眼像差的综合影响及其对远近视力的影响。方法:选取40名平均年龄为48.7±3.4岁,平均视差为1.53±0.58 D的老花眼患者,安装百富美多焦(CooperVision)视镜。测量包括距离和近单眼高(100%)和低对比度(10%)logMAR视力(VA)。用Hartmann-Shack像差仪(IRX3, Imagine Eyes)测量眼像差,并对2 mm和最大圆形自然瞳孔进行分析。结果:优势眼近距离视差显著高于优势眼远距离视差,而非优势眼近距离视差显著高于优势眼(P<0.05)。在2 mm的优势眼中,球样像差(P=0.027)和高阶像差(HOA)显著增加(P=0.002)。非主视眼的球样像差(P=0.001)、彗形像差(P=0.006)和HOA (P=0.004)也显著增加。在最大圆形自然瞳孔大小下,优势眼垂直彗差显著降低(P=0.018),而非优势眼球形和彗差显著增加(P=0.007)。优势眼垂直昏迷与高对比度VA呈显著负相关(Rho= - 0.405, P=0.011);而在非优势眼,高对比度(Rho=0.556, P<0.001)和低对比度(Rho=0.448, P=0.005)下,继发性散光与距离VA有显著相关。结论:MFSCL的眼内视觉表现取决于显性和非显性设计引起的高阶像差以及佩戴者的固有像差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Combined Effect of Ocular and Multifocal Contact Lens Induced Aberrations on Visual Performance: Center-Distance Versus Center-Near Design
Purpose: To evaluate the combined effects of inherent ocular aberrations and induced aberrations with a multifocal soft contact lens (MFCL) after 15 days of lens wear in presbyopic participants and their influence on visual performance at distance and near under high and low contrast conditions. Methods: Forty presbyopic participants (mean age, 48.7±3.4) presenting a mean addition of 1.53±0.58 D were fitted with Biofinity Multifocal (CooperVision) and included in the study. Measurements comprised distance and near monocular high (100%) and low contrast (10%) logMAR visual acuity (VA). Ocular aberrations were obtained with Hartmann–Shack aberrometer (IRX3, Imagine Eyes) and analyzed for 2 mm and maximum round natural pupil. Results: Distance VA was significantly higher in dominant eye, whereas near VA was significantly better in the non-dominant eye (P<0.05 in all conditions). For a 2-mm pupil in the dominant eye fitted with MFCL, spherical-like aberration significantly increased (P=0.027) so as higher-order aberrations (HOA) (P=0.002). A significant increase was also observed in spherical-like aberrations (P=0.001), coma-like aberrations (P=0.006) and HOA (P=0.004) in non-dominant eye. For the maximum round natural pupil size, a significant decrease in vertical coma was observed (P=0.018) in dominant eye, whereas a significant increase in spherical-like (P<0.001) and coma-like aberrations (P=0.007) was observed in non-dominant eye. A negative significant correlation was found between vertical coma and high contrast VA (Rho=−0.405, P=0.011) in dominant eye; whereas in non-dominant eye, a significant correlation was found between induced secondary astigmatism and distance VA under high (Rho=0.556, P<0.001) and low contrast (Rho=0.448, P=0.005). Conclusions: On-eye visual performance of MFSCL is dependent on the high-order aberrations induced by dominant and non-dominant design coupled with the wearer's inherent aberrations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Clinical Profile and Treatment Outcomes of Patients With Acremonium Species Positive Keratitis Managed in a Tertiary Eye Care Center Efficacy of the Image-Guided Alignment System for a Four-Haptic Hydrophobic Monofocal Toric Intraocular Lens Evaluation of Ocular Surface Characteristics in Dry Eye Disease With and Without Soft Contact Lens Wear: A Comparative Study Change in Risk Score and Behaviors of Soft Contact Lens Wearers After Targeted Patient Education Corneal Response to Scleral Contact Lens Wear in Keratoconus
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1