通过对每个数据段的异位量施加约束,提高心率变异性谱的质量

J.J. Chungath, A. Ramanathan, M. Kienzle, G. Myers
{"title":"通过对每个数据段的异位量施加约束,提高心率变异性谱的质量","authors":"J.J. Chungath, A. Ramanathan, M. Kienzle, G. Myers","doi":"10.1109/CIC.1993.378381","DOIUrl":null,"url":null,"abstract":"Heart rate variability (HRV) is primarily due to instability oscillations of homeostatic feedback loops. Each loop tends to oscillate at a frequency characteristic of the time required to traverse that loop. Discarding all segments with ectopy is impractical in a clinical setting, since the number of ectopy-free segments is low even in patients with moderate ectopy. Investigators are extending spectra into lower frequency ranges, which requires longer data segments, and further reduces the number of ectopy-free segments. A method is proposed to determine the level of ectopy above which data segments should be discarded. By enforcing an effective ectopy cutoff, the mean distance among the spectra making up the average periodogram is reduced, increasing the confidence in these spectra. This technique allows for \"quality control\" of the data upon which HRV spectral analysis is based.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"22 1","pages":"727-729"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Improving the quality of heart rate variability spectra by imposing a constraint on the amount of ectopy in each data segment\",\"authors\":\"J.J. Chungath, A. Ramanathan, M. Kienzle, G. Myers\",\"doi\":\"10.1109/CIC.1993.378381\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Heart rate variability (HRV) is primarily due to instability oscillations of homeostatic feedback loops. Each loop tends to oscillate at a frequency characteristic of the time required to traverse that loop. Discarding all segments with ectopy is impractical in a clinical setting, since the number of ectopy-free segments is low even in patients with moderate ectopy. Investigators are extending spectra into lower frequency ranges, which requires longer data segments, and further reduces the number of ectopy-free segments. A method is proposed to determine the level of ectopy above which data segments should be discarded. By enforcing an effective ectopy cutoff, the mean distance among the spectra making up the average periodogram is reduced, increasing the confidence in these spectra. This technique allows for \\\"quality control\\\" of the data upon which HRV spectral analysis is based.<<ETX>>\",\"PeriodicalId\":20445,\"journal\":{\"name\":\"Proceedings of Computers in Cardiology Conference\",\"volume\":\"22 1\",\"pages\":\"727-729\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Computers in Cardiology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1993.378381\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378381","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

心率变异性(HRV)主要是由于稳态反馈回路的不稳定振荡。每个回路都倾向于以与穿越该回路所需时间的频率特性振荡。在临床上摈弃所有异位节段是不切实际的,因为即使在中度异位患者中,无异位节段的数量也很低。研究人员正在将光谱扩展到更低的频率范围,这需要更长的数据段,并进一步减少无异位段的数量。提出了一种确定异位级别的方法,该级别以上的数据段应被丢弃。通过实施有效的异位截止,减少了构成平均周期图的谱间的平均距离,提高了谱间的置信度。该技术允许对HRV光谱分析所依据的数据进行“质量控制”。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Improving the quality of heart rate variability spectra by imposing a constraint on the amount of ectopy in each data segment
Heart rate variability (HRV) is primarily due to instability oscillations of homeostatic feedback loops. Each loop tends to oscillate at a frequency characteristic of the time required to traverse that loop. Discarding all segments with ectopy is impractical in a clinical setting, since the number of ectopy-free segments is low even in patients with moderate ectopy. Investigators are extending spectra into lower frequency ranges, which requires longer data segments, and further reduces the number of ectopy-free segments. A method is proposed to determine the level of ectopy above which data segments should be discarded. By enforcing an effective ectopy cutoff, the mean distance among the spectra making up the average periodogram is reduced, increasing the confidence in these spectra. This technique allows for "quality control" of the data upon which HRV spectral analysis is based.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A 528 channel system for the acquisition and display of defibrillation and electrocardiographic potentials Computers: the heart of screening Signal averaging enhancement by jitter deconvolution Numerical simulation of the flow in model skeletal muscle ventricles Transmembrane potential changes during stimulation in a bidomain model of the myocardium
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1