大景深单活塞换能器设计与制造的新方法

K. Owen, W. Walker
{"title":"大景深单活塞换能器设计与制造的新方法","authors":"K. Owen, W. Walker","doi":"10.1109/ULTSYM.2007.203","DOIUrl":null,"url":null,"abstract":"Traditional focused transducers use multiple elements with individual delays, or a single element and lens to achieve focusing. These approaches involve significant cost, or acoustic losses respectively, and are not well suited to low-cost applications, for example disposable transducers. In contrast, zone plate transducers use the diffraction pattern formed by a variable excitation over the surface of a single element to achieve focusing. Although this results in an inexpensive focused transducer, the focusing performance degrades with broadband excitation, and contrast is limited. Additionally it is difficult to produce diffraction patterns with an extended focal zone. We have developed a successive projection algorithm to optimize the transducer pattern to overcome these limitations and meet desired focusing properties at several frequencies and ranges simultaneously. Within diffraction limits, this technique is shown to significantly outperform conventional zone plate transducers, in some cases reducing sidelobes by as much as 20 dB. Furthermore we show that the necessary transducer patterns can be produced using off-the-shelf PCB technology, and that within the limitations of our fabrication process, we are able to experimentally validate our algorithm.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"1 1","pages":"793-796"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"9C-4 Novel Method for Design and Fabrication of Single Piston Transducers for Extended Depth of Field\",\"authors\":\"K. Owen, W. Walker\",\"doi\":\"10.1109/ULTSYM.2007.203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Traditional focused transducers use multiple elements with individual delays, or a single element and lens to achieve focusing. These approaches involve significant cost, or acoustic losses respectively, and are not well suited to low-cost applications, for example disposable transducers. In contrast, zone plate transducers use the diffraction pattern formed by a variable excitation over the surface of a single element to achieve focusing. Although this results in an inexpensive focused transducer, the focusing performance degrades with broadband excitation, and contrast is limited. Additionally it is difficult to produce diffraction patterns with an extended focal zone. We have developed a successive projection algorithm to optimize the transducer pattern to overcome these limitations and meet desired focusing properties at several frequencies and ranges simultaneously. Within diffraction limits, this technique is shown to significantly outperform conventional zone plate transducers, in some cases reducing sidelobes by as much as 20 dB. Furthermore we show that the necessary transducer patterns can be produced using off-the-shelf PCB technology, and that within the limitations of our fabrication process, we are able to experimentally validate our algorithm.\",\"PeriodicalId\":6355,\"journal\":{\"name\":\"2007 IEEE Ultrasonics Symposium Proceedings\",\"volume\":\"1 1\",\"pages\":\"793-796\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Ultrasonics Symposium Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2007.203\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Ultrasonics Symposium Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2007.203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

传统的聚焦换能器使用具有单独延迟的多个元件,或者使用单个元件和透镜来实现聚焦。这些方法分别涉及巨大的成本或声学损失,并且不太适合低成本应用,例如一次性换能器。相比之下,带板换能器使用由单个元件表面上的可变激发形成的衍射图案来实现聚焦。虽然这是一种廉价的聚焦换能器,但随着宽带激励,聚焦性能下降,对比度有限。此外,很难产生具有扩展焦区的衍射图案。我们开发了一种连续投影算法来优化换能器模式,以克服这些限制,并在多个频率和范围内同时满足所需的聚焦特性。在衍射范围内,该技术的性能明显优于传统的带板换能器,在某些情况下可减少多达20 dB的副瓣。此外,我们表明可以使用现成的PCB技术生产必要的换能器模式,并且在我们的制造工艺的限制内,我们能够通过实验验证我们的算法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
9C-4 Novel Method for Design and Fabrication of Single Piston Transducers for Extended Depth of Field
Traditional focused transducers use multiple elements with individual delays, or a single element and lens to achieve focusing. These approaches involve significant cost, or acoustic losses respectively, and are not well suited to low-cost applications, for example disposable transducers. In contrast, zone plate transducers use the diffraction pattern formed by a variable excitation over the surface of a single element to achieve focusing. Although this results in an inexpensive focused transducer, the focusing performance degrades with broadband excitation, and contrast is limited. Additionally it is difficult to produce diffraction patterns with an extended focal zone. We have developed a successive projection algorithm to optimize the transducer pattern to overcome these limitations and meet desired focusing properties at several frequencies and ranges simultaneously. Within diffraction limits, this technique is shown to significantly outperform conventional zone plate transducers, in some cases reducing sidelobes by as much as 20 dB. Furthermore we show that the necessary transducer patterns can be produced using off-the-shelf PCB technology, and that within the limitations of our fabrication process, we are able to experimentally validate our algorithm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
10B-3 Vibrating Interventional Device Detection Using Real-Time 3D Color Doppler P5E-8 The Method of Reverberation-Ray Matrix - A New Matrix Analysis of Waves in Piezoelectric Laminates P1D-4 Characteristics of a Novel Magnetic Field Sensor Using Piezoelectric Vibrations P5C-3 Field Simulation Parameters Design for Realistic Statistical Parameters of Radio - Frequency Ultrasound Images 2F-1 Fabrication and Performance of a High-Frequency Geometrically Focussed Composite Transducer with Triangular Pillar Geometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1