COVID-19大流行期间20所苏格兰小学不同通风系统教室的室内二氧化碳和热状况

Natalie Bain-Reguis, Andrew Smith, Caroline Hollins Martin, J. Currie
{"title":"COVID-19大流行期间20所苏格兰小学不同通风系统教室的室内二氧化碳和热状况","authors":"Natalie Bain-Reguis, Andrew Smith, Caroline Hollins Martin, J. Currie","doi":"10.3390/pollutants2020014","DOIUrl":null,"url":null,"abstract":"Healthy indoor environments influence the comfort, health and wellbeing of the occupants. Monitoring the indoor temperature, relative humidity and CO2 levels in primary schools during the COVID-19 pandemic was mandated by a local authority in Scotland. The aim was to investigate the comfort and safety of the teachers and their pupils. This paper presents the measurements of indoor climate in 20 classrooms in four different primary schools in Scotland. The schools were of different architypes. The classrooms were of different sizes, orientations and occupancy, and had different ventilation systems. Ventilation was achieved either by manually opening the windows, or by a mechanical ventilation system. Indoor air temperature, relative humidity and carbon dioxide (CO2) concentrations were continuously monitored for one week during the heating season 2020/21. Occupancy and opening of the windows were logged in by the teachers. The ventilation rates in the classrooms were estimated by measuring the CO2 concentrations. On the 20 classrooms of the study, data of 19 were analysed. The results show that four of the five mechanically ventilated classrooms performed better than natural ventilation, which indicates that opening the windows depended on the customs and habits. Classrooms in naturally ventilated Victorian buildings have the worst average ventilation rate (4.38 L/s per person) compared to the other classrooms (5.8 L/s per person for the more recent naturally ventilated ones, and 6.08 L/s per person for the mechanically ventilated ones). The results of this preliminary study will be used as the basis to find ways to ensure adequate ventilation in natural ventilated classrooms.","PeriodicalId":20301,"journal":{"name":"Pollutants","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Indoor CO2 and Thermal Conditions in Twenty Scottish Primary School Classrooms with Different Ventilation Systems during the COVID-19 Pandemic\",\"authors\":\"Natalie Bain-Reguis, Andrew Smith, Caroline Hollins Martin, J. Currie\",\"doi\":\"10.3390/pollutants2020014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Healthy indoor environments influence the comfort, health and wellbeing of the occupants. Monitoring the indoor temperature, relative humidity and CO2 levels in primary schools during the COVID-19 pandemic was mandated by a local authority in Scotland. The aim was to investigate the comfort and safety of the teachers and their pupils. This paper presents the measurements of indoor climate in 20 classrooms in four different primary schools in Scotland. The schools were of different architypes. The classrooms were of different sizes, orientations and occupancy, and had different ventilation systems. Ventilation was achieved either by manually opening the windows, or by a mechanical ventilation system. Indoor air temperature, relative humidity and carbon dioxide (CO2) concentrations were continuously monitored for one week during the heating season 2020/21. Occupancy and opening of the windows were logged in by the teachers. The ventilation rates in the classrooms were estimated by measuring the CO2 concentrations. On the 20 classrooms of the study, data of 19 were analysed. The results show that four of the five mechanically ventilated classrooms performed better than natural ventilation, which indicates that opening the windows depended on the customs and habits. Classrooms in naturally ventilated Victorian buildings have the worst average ventilation rate (4.38 L/s per person) compared to the other classrooms (5.8 L/s per person for the more recent naturally ventilated ones, and 6.08 L/s per person for the mechanically ventilated ones). The results of this preliminary study will be used as the basis to find ways to ensure adequate ventilation in natural ventilated classrooms.\",\"PeriodicalId\":20301,\"journal\":{\"name\":\"Pollutants\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pollutants\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/pollutants2020014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pollutants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/pollutants2020014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

健康的室内环境影响着居住者的舒适、健康和幸福。苏格兰地方当局要求在2019冠状病毒病大流行期间监测小学的室内温度、相对湿度和二氧化碳水平。目的是调查教师和学生的舒适度和安全性。本文介绍了苏格兰四所不同小学20间教室的室内气候测量。这些学校的建筑风格各不相同。教室的大小、朝向和占用情况各不相同,并且有不同的通风系统。通风可以通过手动打开窗户或通过机械通风系统来实现。在2020/21采暖季,连续监测一周室内空气温度、相对湿度和二氧化碳浓度。占用和打开窗户的记录都是由老师记录的。通过测量二氧化碳浓度来估计教室的通风率。在研究的20个教室中,分析了19个教室的数据。结果表明,在5个机械通风教室中,有4个教室的开窗效果优于自然通风教室,说明开窗取决于风俗习惯。自然通风的维多利亚式建筑的教室与其他教室相比,平均通风率最差(4.38 L/s /人)(较新自然通风的教室为5.8 L/s /人,机械通风的教室为6.08 L/s /人)。这项初步研究的结果将作为寻找确保自然通风教室充分通风的方法的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Indoor CO2 and Thermal Conditions in Twenty Scottish Primary School Classrooms with Different Ventilation Systems during the COVID-19 Pandemic
Healthy indoor environments influence the comfort, health and wellbeing of the occupants. Monitoring the indoor temperature, relative humidity and CO2 levels in primary schools during the COVID-19 pandemic was mandated by a local authority in Scotland. The aim was to investigate the comfort and safety of the teachers and their pupils. This paper presents the measurements of indoor climate in 20 classrooms in four different primary schools in Scotland. The schools were of different architypes. The classrooms were of different sizes, orientations and occupancy, and had different ventilation systems. Ventilation was achieved either by manually opening the windows, or by a mechanical ventilation system. Indoor air temperature, relative humidity and carbon dioxide (CO2) concentrations were continuously monitored for one week during the heating season 2020/21. Occupancy and opening of the windows were logged in by the teachers. The ventilation rates in the classrooms were estimated by measuring the CO2 concentrations. On the 20 classrooms of the study, data of 19 were analysed. The results show that four of the five mechanically ventilated classrooms performed better than natural ventilation, which indicates that opening the windows depended on the customs and habits. Classrooms in naturally ventilated Victorian buildings have the worst average ventilation rate (4.38 L/s per person) compared to the other classrooms (5.8 L/s per person for the more recent naturally ventilated ones, and 6.08 L/s per person for the mechanically ventilated ones). The results of this preliminary study will be used as the basis to find ways to ensure adequate ventilation in natural ventilated classrooms.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Calcium-Associated Anions Play a Dual Role in Modulating Cadmium Uptake and Translocation in Wheat Forecasting End-of-Life Vehicle Generation in the EU-27: A Hybrid LSTM-Based Forecasting and Grey Systems Theory-Based Backcasting Approach Isotopic Differentiation (δ18OPO4) of Inorganic Phosphorus among Organic Wastes for Nutrient Runoff Tracing Studies: A Summary of the Literature with Refinement of Livestock Estimates for Grand Lake St. Marys Watershed (Ohio) Arsenic Contamination Needs Serious Attention: An Opinion and Global Scenario Measuring Biogenic Volatile Organic Compounds from Leaves Exposed to Submicron Black Carbon Using Portable Sensor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1