C. Fryer, H. Tan, Roshitha Bakmeedeniya, P. Friedland
{"title":"颈椎前路椎间盘切除术和融合术后硬体移位引起的迟发性吞咽困难:一个不寻常的原因和文献回顾","authors":"C. Fryer, H. Tan, Roshitha Bakmeedeniya, P. Friedland","doi":"10.1177/1179550619881131","DOIUrl":null,"url":null,"abstract":"Post-operative dysphagia is the most common complication following anterior cervical discectomy and fusion (ACDF), with reports varying from 1% to 79%. We report a case of a 63-year-old female patient complaining of dysphagia presenting 9 years post surgery. The cause of dysphagia is often multifactorial with the true aetiology poorly understood. One potentially life-threatening cause of post-operative dysphagia is hardware migration associated with pharyngoesophageal perforation. This patient presents a unique case of a conservatively managed hardware migration with delayed onset dysphagia after 8 years of minimal symptoms. On further investigation, barium swallow identified a freely mobile screw in the oesophageal submucosa, rotating on swallowing. Retrieval of the screw was achieved transcervically with no visible perforation and resolution of dysphagia occurred 1 week post-operatively. Understanding the aetiology with early diagnosis and appropriate management of delayed hardware migration are paramount in reducing patient morbidity and potential life-threatening otolaryngologic complications.","PeriodicalId":89906,"journal":{"name":"Clinical medicine insights. Ear, nose and throat","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Late-Onset Dysphagia From Hardware Migration After Anterior Cervical Discectomy and Fusion: An Unusual Cause and Review of Literature\",\"authors\":\"C. Fryer, H. Tan, Roshitha Bakmeedeniya, P. Friedland\",\"doi\":\"10.1177/1179550619881131\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Post-operative dysphagia is the most common complication following anterior cervical discectomy and fusion (ACDF), with reports varying from 1% to 79%. We report a case of a 63-year-old female patient complaining of dysphagia presenting 9 years post surgery. The cause of dysphagia is often multifactorial with the true aetiology poorly understood. One potentially life-threatening cause of post-operative dysphagia is hardware migration associated with pharyngoesophageal perforation. This patient presents a unique case of a conservatively managed hardware migration with delayed onset dysphagia after 8 years of minimal symptoms. On further investigation, barium swallow identified a freely mobile screw in the oesophageal submucosa, rotating on swallowing. Retrieval of the screw was achieved transcervically with no visible perforation and resolution of dysphagia occurred 1 week post-operatively. Understanding the aetiology with early diagnosis and appropriate management of delayed hardware migration are paramount in reducing patient morbidity and potential life-threatening otolaryngologic complications.\",\"PeriodicalId\":89906,\"journal\":{\"name\":\"Clinical medicine insights. Ear, nose and throat\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical medicine insights. Ear, nose and throat\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1179550619881131\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical medicine insights. Ear, nose and throat","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1179550619881131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Late-Onset Dysphagia From Hardware Migration After Anterior Cervical Discectomy and Fusion: An Unusual Cause and Review of Literature
Post-operative dysphagia is the most common complication following anterior cervical discectomy and fusion (ACDF), with reports varying from 1% to 79%. We report a case of a 63-year-old female patient complaining of dysphagia presenting 9 years post surgery. The cause of dysphagia is often multifactorial with the true aetiology poorly understood. One potentially life-threatening cause of post-operative dysphagia is hardware migration associated with pharyngoesophageal perforation. This patient presents a unique case of a conservatively managed hardware migration with delayed onset dysphagia after 8 years of minimal symptoms. On further investigation, barium swallow identified a freely mobile screw in the oesophageal submucosa, rotating on swallowing. Retrieval of the screw was achieved transcervically with no visible perforation and resolution of dysphagia occurred 1 week post-operatively. Understanding the aetiology with early diagnosis and appropriate management of delayed hardware migration are paramount in reducing patient morbidity and potential life-threatening otolaryngologic complications.