全景x线摄影和锥束计算机断层成像在识别和测量精神神经前环方面的比较准确性:荟萃分析和文献综述

D. Raj, Soumitra Ghosh, Samiran Das, Shubhabrata Roy, S. Majumdar
{"title":"全景x线摄影和锥束计算机断层成像在识别和测量精神神经前环方面的比较准确性:荟萃分析和文献综述","authors":"D. Raj, Soumitra Ghosh, Samiran Das, Shubhabrata Roy, S. Majumdar","doi":"10.5005/jp-journals-10019-1322","DOIUrl":null,"url":null,"abstract":"Aim and objective: This study aimed to assess the relative accuracy of two-dimensional panoramic radiographs compared with three-dimensional computed tomography (CBCT) images for identification and measurement of the anterior loop of the mental nerve. Materials and methods: The study was about to determine the comparative diagnostic accuracy of panoramic radiograph and cone-beam computed tomography and the study protocol was set according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline. The search was limited to English literature only and included an electronic search through PubMed and Google Scholar databases. The search was further complemented by extensive hand-searching. All studies published up to November 2019 were included (without any starting limit). Two independent investigators extracted the data and assessed the studies based on the inclusion and exclusion criteria. Results: Out of the initial 308 records, only 4 studies were included in this review for qualitative data synthesis. The quality assessment of included studies was done through QUADAS-2. Quantitative data synthesis was done to compare the relative accuracy of two-dimensional radiographs compared with three-dimensional scans from three out of the four selected articles. Statistical analysis was done with the help of Meta-DiSc version 1.4. The pooled sensitivity of panoramic radiography was 0.45 (CI 95%: 0.34–0.56) and pooled specificity was 0.75 (CI 95%: 0.69–0.80). In the symmetric summary receiver operating characteristic (SROC) plot, the area under the curve (AUC) was 0.8832, and Q * was 0.8137. Conclusion: Compared with cone-beam computed tomography (CBCT) images as the gold standard reference test, two-dimensional panoramic radiographs showed lower sensitivity and reasonable specificity. It is clear from the SROC curve that panoramic radiography can be used for the identification of the anterior loops. Still, it is better to avoid it as an alternative to three-dimensional scans to determine the presence and extension of the anterior loop of the mental nerve because of the tendency toward low sensitivity and over or under-estimation of the length.","PeriodicalId":14246,"journal":{"name":"International Journal of Prosthodontics and Restorative Dentistry","volume":"120 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Accuracy of Panoramic Radiograph and Cone-beam Computed Tomography Images in Identification and Measurement of the Anterior Loop of Mental Nerve: A Meta-analysis and Review of the Literature\",\"authors\":\"D. Raj, Soumitra Ghosh, Samiran Das, Shubhabrata Roy, S. Majumdar\",\"doi\":\"10.5005/jp-journals-10019-1322\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim and objective: This study aimed to assess the relative accuracy of two-dimensional panoramic radiographs compared with three-dimensional computed tomography (CBCT) images for identification and measurement of the anterior loop of the mental nerve. Materials and methods: The study was about to determine the comparative diagnostic accuracy of panoramic radiograph and cone-beam computed tomography and the study protocol was set according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline. The search was limited to English literature only and included an electronic search through PubMed and Google Scholar databases. The search was further complemented by extensive hand-searching. All studies published up to November 2019 were included (without any starting limit). Two independent investigators extracted the data and assessed the studies based on the inclusion and exclusion criteria. Results: Out of the initial 308 records, only 4 studies were included in this review for qualitative data synthesis. The quality assessment of included studies was done through QUADAS-2. Quantitative data synthesis was done to compare the relative accuracy of two-dimensional radiographs compared with three-dimensional scans from three out of the four selected articles. Statistical analysis was done with the help of Meta-DiSc version 1.4. The pooled sensitivity of panoramic radiography was 0.45 (CI 95%: 0.34–0.56) and pooled specificity was 0.75 (CI 95%: 0.69–0.80). In the symmetric summary receiver operating characteristic (SROC) plot, the area under the curve (AUC) was 0.8832, and Q * was 0.8137. Conclusion: Compared with cone-beam computed tomography (CBCT) images as the gold standard reference test, two-dimensional panoramic radiographs showed lower sensitivity and reasonable specificity. It is clear from the SROC curve that panoramic radiography can be used for the identification of the anterior loops. Still, it is better to avoid it as an alternative to three-dimensional scans to determine the presence and extension of the anterior loop of the mental nerve because of the tendency toward low sensitivity and over or under-estimation of the length.\",\"PeriodicalId\":14246,\"journal\":{\"name\":\"International Journal of Prosthodontics and Restorative Dentistry\",\"volume\":\"120 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Prosthodontics and Restorative Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5005/jp-journals-10019-1322\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics and Restorative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10019-1322","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的和目的:本研究旨在评估二维全景x线片与三维计算机断层扫描(CBCT)图像在识别和测量精神神经前环方面的相对准确性。材料和方法:本研究拟确定全景x线摄影和锥束计算机断层扫描的诊断准确性比较,并根据系统评价和荟萃分析首选报告项目(PRISMA)诊断测试准确性指南制定研究方案。搜索仅限于英文文献,并包括通过PubMed和Google Scholar数据库进行的电子搜索。广泛的人工搜索进一步补充了搜索工作。纳入截至2019年11月发表的所有研究(没有任何起始限制)。两名独立研究人员提取数据并根据纳入和排除标准对研究进行评估。结果:在最初的308项记录中,只有4项研究被纳入本综述进行定性数据综合。通过QUADAS-2进行纳入研究的质量评估。定量数据合成是为了比较四篇选定文章中三篇的二维x光片与三维扫描的相对准确性。在Meta-DiSc 1.4版的帮助下进行统计分析。全景x线摄影的综合敏感性为0.45 (CI 95%: 0.34-0.56),综合特异性为0.75 (CI 95%: 0.69-0.80)。对称型接收者工作特征(SROC)曲线下面积(AUC)为0.8832,Q *为0.8137。结论:与锥束ct (cone-beam computed tomography, CBCT)图像作为金标准对照试验相比,二维全景x线片的灵敏度较低,特异度合理。从SROC曲线可以清楚地看出,全景x线摄影可以用于识别前袢。尽管如此,最好还是避免用它来代替三维扫描来确定精神神经前环的存在和延伸,因为三维扫描的灵敏度往往较低,对长度的估计也会过高或过低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative Accuracy of Panoramic Radiograph and Cone-beam Computed Tomography Images in Identification and Measurement of the Anterior Loop of Mental Nerve: A Meta-analysis and Review of the Literature
Aim and objective: This study aimed to assess the relative accuracy of two-dimensional panoramic radiographs compared with three-dimensional computed tomography (CBCT) images for identification and measurement of the anterior loop of the mental nerve. Materials and methods: The study was about to determine the comparative diagnostic accuracy of panoramic radiograph and cone-beam computed tomography and the study protocol was set according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline. The search was limited to English literature only and included an electronic search through PubMed and Google Scholar databases. The search was further complemented by extensive hand-searching. All studies published up to November 2019 were included (without any starting limit). Two independent investigators extracted the data and assessed the studies based on the inclusion and exclusion criteria. Results: Out of the initial 308 records, only 4 studies were included in this review for qualitative data synthesis. The quality assessment of included studies was done through QUADAS-2. Quantitative data synthesis was done to compare the relative accuracy of two-dimensional radiographs compared with three-dimensional scans from three out of the four selected articles. Statistical analysis was done with the help of Meta-DiSc version 1.4. The pooled sensitivity of panoramic radiography was 0.45 (CI 95%: 0.34–0.56) and pooled specificity was 0.75 (CI 95%: 0.69–0.80). In the symmetric summary receiver operating characteristic (SROC) plot, the area under the curve (AUC) was 0.8832, and Q * was 0.8137. Conclusion: Compared with cone-beam computed tomography (CBCT) images as the gold standard reference test, two-dimensional panoramic radiographs showed lower sensitivity and reasonable specificity. It is clear from the SROC curve that panoramic radiography can be used for the identification of the anterior loops. Still, it is better to avoid it as an alternative to three-dimensional scans to determine the presence and extension of the anterior loop of the mental nerve because of the tendency toward low sensitivity and over or under-estimation of the length.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
0
期刊最新文献
Comparative Evaluation of Fitness and Compressive Strength of Temporary Crowns Designed from 3Shape and Exocad Software: An In Vitro Study Evaluation of the Strain under Compression and Surface Roughness of Tissue Conditioners Incorporated with Silver Nano Particles and Chlorhexidine: An In Vitro Study Natural Tooth Wear Opposing to Different Prosthetic Crown Materials Dimensional Stability of Maxillofacial Prosthetic Room Temperature Vulcanized Silicones after Various Disinfection Protocols: An In Vitro Study Effect of Flap and Flapless Implant Surgical Techniques on Tissues around Dental Implants: An In Vivo Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1