{"title":"NaCl和LiF对冰晶石基铝电解液液相温度的影响","authors":"Qiu Zhu-xian","doi":"10.1149/ma2006-02/1/4","DOIUrl":null,"url":null,"abstract":"A new method for measurement of liquidus temperature of aluminum electrolyte system with one meter connected to COM port of a computer is introduced.Liquidus temperature is determined based on cooling curve by using thermal analysis method.Liquidus temperatures of NaF and NaCl are measured for comparison.The results prove the method to be reliable and accurate.The range of error is about 1-1.5 ℃ from 801 ℃ to 995 ℃.The effects of NaCl and LiF on liquidus temperature of molten cryolite-based aluminum electrolyte are studied and the mathematical model is established based on the experimental results obtained by this method.The mathematical model obtained is T=947.588-5.907×w(LiF)-6.223×w(NaCl).The experiments show that the mix addition of NaCl and LiF into molten cryolite-based aluminum electrolyte not only reduces effectively the liquidus temperature of electrolyte but also decreases the production cost and increases the economic benefits.","PeriodicalId":35632,"journal":{"name":"Yejin Fenxi/Metallurgical Analysis","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Effect of NaCl and LiF on liquidus temperature of molten cryolite-based aluminum electrolyte\",\"authors\":\"Qiu Zhu-xian\",\"doi\":\"10.1149/ma2006-02/1/4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new method for measurement of liquidus temperature of aluminum electrolyte system with one meter connected to COM port of a computer is introduced.Liquidus temperature is determined based on cooling curve by using thermal analysis method.Liquidus temperatures of NaF and NaCl are measured for comparison.The results prove the method to be reliable and accurate.The range of error is about 1-1.5 ℃ from 801 ℃ to 995 ℃.The effects of NaCl and LiF on liquidus temperature of molten cryolite-based aluminum electrolyte are studied and the mathematical model is established based on the experimental results obtained by this method.The mathematical model obtained is T=947.588-5.907×w(LiF)-6.223×w(NaCl).The experiments show that the mix addition of NaCl and LiF into molten cryolite-based aluminum electrolyte not only reduces effectively the liquidus temperature of electrolyte but also decreases the production cost and increases the economic benefits.\",\"PeriodicalId\":35632,\"journal\":{\"name\":\"Yejin Fenxi/Metallurgical Analysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Yejin Fenxi/Metallurgical Analysis\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.1149/ma2006-02/1/4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Materials Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Yejin Fenxi/Metallurgical Analysis","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.1149/ma2006-02/1/4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Materials Science","Score":null,"Total":0}
引用次数: 6

摘要

介绍了一种用仪表连接计算机的COM口测量铝电解液体系液相温度的新方法。利用热分析法,根据冷却曲线确定液相温度。测定了NaF和NaCl的液相温度进行比较。结果表明,该方法可靠、准确。801℃~ 995℃,误差范围约为1 ~ 1.5℃。研究了NaCl和LiF对冰晶石基铝电解液液相温度的影响,并根据实验结果建立了数学模型。得到的数学模型为T=947.588-5.907×w(liff)-6.223×w(NaCl)。实验表明,在冰晶石基铝电解液中混合加入NaCl和LiF,不仅有效降低了电解液的液相温度,而且降低了生产成本,提高了经济效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of NaCl and LiF on liquidus temperature of molten cryolite-based aluminum electrolyte
A new method for measurement of liquidus temperature of aluminum electrolyte system with one meter connected to COM port of a computer is introduced.Liquidus temperature is determined based on cooling curve by using thermal analysis method.Liquidus temperatures of NaF and NaCl are measured for comparison.The results prove the method to be reliable and accurate.The range of error is about 1-1.5 ℃ from 801 ℃ to 995 ℃.The effects of NaCl and LiF on liquidus temperature of molten cryolite-based aluminum electrolyte are studied and the mathematical model is established based on the experimental results obtained by this method.The mathematical model obtained is T=947.588-5.907×w(LiF)-6.223×w(NaCl).The experiments show that the mix addition of NaCl and LiF into molten cryolite-based aluminum electrolyte not only reduces effectively the liquidus temperature of electrolyte but also decreases the production cost and increases the economic benefits.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Yejin Fenxi/Metallurgical Analysis
Yejin Fenxi/Metallurgical Analysis Materials Science-Metals and Alloys
CiteScore
0.80
自引率
0.00%
发文量
7744
期刊最新文献
Effect of NaCl and LiF on liquidus temperature of molten cryolite-based aluminum electrolyte
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1