{"title":"对不同类型的用于测量血压、温度和血糖的医疗设备的准确性进行了调查","authors":"Ahmed Q. Ans, Abdullah M. Jawad, Mayasseen Y. Abdul-Razak, Noor-alhuda Y. Abdul-Razak","doi":"10.33762/mjbu.2018.145030","DOIUrl":null,"url":null,"abstract":"Background: A variety of methods are now available to measure blood pressure, blood glucose and body temperature using different devices. As an example, blood pressure can be measured by the standard mercury sphygmomanometer method, it can also be measured electronically. It is not known to what extent they are correlated with each other when used in our locality. Objectives: To compare the quality and accuracy of different methods used to measure blood pressure (manual versus automated office blood pressure measurements), blood glucose (glucometer with the laboratory reference method) and body temperature (glass mercury thermometer and digital thermometer). Methods: All measurements were done at Basrah General Hospital during the period from 5 of March to 15 of March, 2017. Measurements for each patient were performed by the same subject. Patients were selected from the surgical wards of Basrah General Hospital. Blood pressure was recorded using both automated oscillometric blood pressure device (Beurer blood pressure monitor) and the standard manual mercury sphygmomanometer for each patient. Blood glucose was estimated using the Accu-Chek glucometer and compared with laboratory data of the same hospital. Capillary blood samples were collected and checked on a glucometer and venous blood sample was sent to the laboratory for glucose estimation at the same time. The laboratory value was used as a reference for comparison. Temperature was recorded using glass mercury thermometer and two types of digital thermometers; one used on forehead (Pic thermometer) and the other used orally (Beurer thermometer). SPSS version 20 was used for statistical analysis. Results: There was no significant difference in the measurement of systolic and diastolic blood pressure by the two methods used in this study; mercury sphygmomanometer and automated oscillometric device (systolic blood pressure 127.75 ± 22.01 mercury versus 128.95 ± 18.7 electronic; similarly for diastolic). The two methods were significantly correlated with each other. Random blood glucose measured by a glucometer and a hospital laboratory method showed that glucometers gave significantly higher values by around 30%. Despite these higher readings, the two methods were still significantly correlated. The three methods used to measure body temperature showed a significant correlation with similar mean values (36.46 ± 0.58, 36.62 ± 0.57, and 36.41 ± 0.51 for forehead electronic, oral electronic, and oral mercury respectively). Conclusion: The methods used to measure blood pressure, blood glucose and body temperature are well correlated with each other, and gave approximately similar readings except the measurement of blood glucose by Accu-check glucometer which gave higher values than the reference laboratory method.","PeriodicalId":33859,"journal":{"name":"The Medical Journal of Basrah University","volume":"61 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An investigation into the accuracy of different types of medical devices used in measurement of blood pressure, temperature and blood glucose\",\"authors\":\"Ahmed Q. Ans, Abdullah M. Jawad, Mayasseen Y. Abdul-Razak, Noor-alhuda Y. Abdul-Razak\",\"doi\":\"10.33762/mjbu.2018.145030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: A variety of methods are now available to measure blood pressure, blood glucose and body temperature using different devices. As an example, blood pressure can be measured by the standard mercury sphygmomanometer method, it can also be measured electronically. It is not known to what extent they are correlated with each other when used in our locality. Objectives: To compare the quality and accuracy of different methods used to measure blood pressure (manual versus automated office blood pressure measurements), blood glucose (glucometer with the laboratory reference method) and body temperature (glass mercury thermometer and digital thermometer). Methods: All measurements were done at Basrah General Hospital during the period from 5 of March to 15 of March, 2017. Measurements for each patient were performed by the same subject. Patients were selected from the surgical wards of Basrah General Hospital. Blood pressure was recorded using both automated oscillometric blood pressure device (Beurer blood pressure monitor) and the standard manual mercury sphygmomanometer for each patient. Blood glucose was estimated using the Accu-Chek glucometer and compared with laboratory data of the same hospital. Capillary blood samples were collected and checked on a glucometer and venous blood sample was sent to the laboratory for glucose estimation at the same time. The laboratory value was used as a reference for comparison. Temperature was recorded using glass mercury thermometer and two types of digital thermometers; one used on forehead (Pic thermometer) and the other used orally (Beurer thermometer). SPSS version 20 was used for statistical analysis. Results: There was no significant difference in the measurement of systolic and diastolic blood pressure by the two methods used in this study; mercury sphygmomanometer and automated oscillometric device (systolic blood pressure 127.75 ± 22.01 mercury versus 128.95 ± 18.7 electronic; similarly for diastolic). The two methods were significantly correlated with each other. Random blood glucose measured by a glucometer and a hospital laboratory method showed that glucometers gave significantly higher values by around 30%. Despite these higher readings, the two methods were still significantly correlated. The three methods used to measure body temperature showed a significant correlation with similar mean values (36.46 ± 0.58, 36.62 ± 0.57, and 36.41 ± 0.51 for forehead electronic, oral electronic, and oral mercury respectively). Conclusion: The methods used to measure blood pressure, blood glucose and body temperature are well correlated with each other, and gave approximately similar readings except the measurement of blood glucose by Accu-check glucometer which gave higher values than the reference laboratory method.\",\"PeriodicalId\":33859,\"journal\":{\"name\":\"The Medical Journal of Basrah University\",\"volume\":\"61 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Medical Journal of Basrah University\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33762/mjbu.2018.145030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Medical Journal of Basrah University","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33762/mjbu.2018.145030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An investigation into the accuracy of different types of medical devices used in measurement of blood pressure, temperature and blood glucose
Background: A variety of methods are now available to measure blood pressure, blood glucose and body temperature using different devices. As an example, blood pressure can be measured by the standard mercury sphygmomanometer method, it can also be measured electronically. It is not known to what extent they are correlated with each other when used in our locality. Objectives: To compare the quality and accuracy of different methods used to measure blood pressure (manual versus automated office blood pressure measurements), blood glucose (glucometer with the laboratory reference method) and body temperature (glass mercury thermometer and digital thermometer). Methods: All measurements were done at Basrah General Hospital during the period from 5 of March to 15 of March, 2017. Measurements for each patient were performed by the same subject. Patients were selected from the surgical wards of Basrah General Hospital. Blood pressure was recorded using both automated oscillometric blood pressure device (Beurer blood pressure monitor) and the standard manual mercury sphygmomanometer for each patient. Blood glucose was estimated using the Accu-Chek glucometer and compared with laboratory data of the same hospital. Capillary blood samples were collected and checked on a glucometer and venous blood sample was sent to the laboratory for glucose estimation at the same time. The laboratory value was used as a reference for comparison. Temperature was recorded using glass mercury thermometer and two types of digital thermometers; one used on forehead (Pic thermometer) and the other used orally (Beurer thermometer). SPSS version 20 was used for statistical analysis. Results: There was no significant difference in the measurement of systolic and diastolic blood pressure by the two methods used in this study; mercury sphygmomanometer and automated oscillometric device (systolic blood pressure 127.75 ± 22.01 mercury versus 128.95 ± 18.7 electronic; similarly for diastolic). The two methods were significantly correlated with each other. Random blood glucose measured by a glucometer and a hospital laboratory method showed that glucometers gave significantly higher values by around 30%. Despite these higher readings, the two methods were still significantly correlated. The three methods used to measure body temperature showed a significant correlation with similar mean values (36.46 ± 0.58, 36.62 ± 0.57, and 36.41 ± 0.51 for forehead electronic, oral electronic, and oral mercury respectively). Conclusion: The methods used to measure blood pressure, blood glucose and body temperature are well correlated with each other, and gave approximately similar readings except the measurement of blood glucose by Accu-check glucometer which gave higher values than the reference laboratory method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
18 weeks
期刊最新文献
Knowledge, attitude and practices regarding COVID-19 outbreak among people in Basrah city Association of serum uric acid with markers of inflammations And disease severity in ankylosing spondylitis patients The Relationship Between Body Mass Index and Acne Vulgaris – A Comparative Study prevalence of left ventricular diastolic dysfunction in patients attending a cardiology clinic. Prevalence and predictors of severe metabolic acidosis in chronic kidney disease stage 3-5
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1