{"title":"P2B-10二次谐波像差校正","authors":"H. Kaupang, T. Varslot, S. Måsøy","doi":"10.1109/ULTSYM.2007.387","DOIUrl":null,"url":null,"abstract":"A simulation study is performed to present results concerning 3D aberration correction for harmonic imaging. Two different correction schemes (a pure time-delay correction and a time-delay and amplitude correction) are employed along with estimation based on either the received first- or second-harmonic frequency. An aberrating body wall is implemented as a 20 mm delay-screen body wall using eight screens, and is tuned to match human abdominal wall characteristics. The transmit pressure of the first harmonic is set to not succeed a mechanical index of 1.1 for the uncorrected case and a pure time-delay correction. Using a time-delay and amplitude correction, the total acoustic energy transmitted is equal to that of the uncorrected case. The total amount of generated second-harmonic energy increases with approximately 1 dB for a pure time-delay correction and about 2 dB for a time-delay and amplitude correction, both estimated at the received first-harmonic frequency. The general side-lobe level of the first- and second-harmonic focal point beam profile averaged over circles around the transducer axis is lowered with 2-10 dB for both correction schemes relative to the uncorrected case.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"69 1","pages":"1537-1540"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"P2B-10 Second-Harmonic Aberration Correction\",\"authors\":\"H. Kaupang, T. Varslot, S. Måsøy\",\"doi\":\"10.1109/ULTSYM.2007.387\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simulation study is performed to present results concerning 3D aberration correction for harmonic imaging. Two different correction schemes (a pure time-delay correction and a time-delay and amplitude correction) are employed along with estimation based on either the received first- or second-harmonic frequency. An aberrating body wall is implemented as a 20 mm delay-screen body wall using eight screens, and is tuned to match human abdominal wall characteristics. The transmit pressure of the first harmonic is set to not succeed a mechanical index of 1.1 for the uncorrected case and a pure time-delay correction. Using a time-delay and amplitude correction, the total acoustic energy transmitted is equal to that of the uncorrected case. The total amount of generated second-harmonic energy increases with approximately 1 dB for a pure time-delay correction and about 2 dB for a time-delay and amplitude correction, both estimated at the received first-harmonic frequency. The general side-lobe level of the first- and second-harmonic focal point beam profile averaged over circles around the transducer axis is lowered with 2-10 dB for both correction schemes relative to the uncorrected case.\",\"PeriodicalId\":6355,\"journal\":{\"name\":\"2007 IEEE Ultrasonics Symposium Proceedings\",\"volume\":\"69 1\",\"pages\":\"1537-1540\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Ultrasonics Symposium Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2007.387\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Ultrasonics Symposium Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2007.387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

对谐波成像的三维像差校正进行了仿真研究。采用两种不同的校正方案(纯时延校正和时延和幅度校正)以及基于接收到的一谐波或二谐波频率的估计。畸变体壁被实现为一个20毫米的延迟屏幕体壁,使用8个屏幕,并调整到符合人体腹壁特征。对于未校正的情况和纯延时校正,将第一次谐波的传输压力设置为不继承1.1的机械指标。通过时间延迟和振幅校正,传输的总声波能量等于未校正的情况。在接收到的一次谐波频率估计下,纯时延校正产生的二次谐波能量总量增加约1 dB,延时和幅度校正产生的二次谐波能量总量增加约2 dB。相对于未校正的情况,两种校正方案的一谐波和二次谐波焦点光束轮廓的一般旁瓣电平在围绕换能器轴的圆上平均降低了2-10 dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
P2B-10 Second-Harmonic Aberration Correction
A simulation study is performed to present results concerning 3D aberration correction for harmonic imaging. Two different correction schemes (a pure time-delay correction and a time-delay and amplitude correction) are employed along with estimation based on either the received first- or second-harmonic frequency. An aberrating body wall is implemented as a 20 mm delay-screen body wall using eight screens, and is tuned to match human abdominal wall characteristics. The transmit pressure of the first harmonic is set to not succeed a mechanical index of 1.1 for the uncorrected case and a pure time-delay correction. Using a time-delay and amplitude correction, the total acoustic energy transmitted is equal to that of the uncorrected case. The total amount of generated second-harmonic energy increases with approximately 1 dB for a pure time-delay correction and about 2 dB for a time-delay and amplitude correction, both estimated at the received first-harmonic frequency. The general side-lobe level of the first- and second-harmonic focal point beam profile averaged over circles around the transducer axis is lowered with 2-10 dB for both correction schemes relative to the uncorrected case.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
10B-3 Vibrating Interventional Device Detection Using Real-Time 3D Color Doppler P5E-8 The Method of Reverberation-Ray Matrix - A New Matrix Analysis of Waves in Piezoelectric Laminates P1D-4 Characteristics of a Novel Magnetic Field Sensor Using Piezoelectric Vibrations P5C-3 Field Simulation Parameters Design for Realistic Statistical Parameters of Radio - Frequency Ultrasound Images 2F-1 Fabrication and Performance of a High-Frequency Geometrically Focussed Composite Transducer with Triangular Pillar Geometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1