使用具有超疏水表面的浓缩装置分析实际样品中的重金属离子

I. Yanagimachi, N. Nashida, K. Iwasa, H. Suzuki
{"title":"使用具有超疏水表面的浓缩装置分析实际样品中的重金属离子","authors":"I. Yanagimachi, N. Nashida, K. Iwasa, H. Suzuki","doi":"10.1109/SENSOR.2007.4300411","DOIUrl":null,"url":null,"abstract":"Heavy metal ions in soil samples were analyzed by a novel method based on evaporative concentration. The detector chip had a microelectrode array as a working electrode and a Ag/AgCl reference electrode surrounded by a super-hydrophobic layer formed with polytetrafluoroethylene (PTFE) beads. A sample droplet formed on the electrode area was shrunk to concentrate the solution. Cd2+ , Pb2+ , and As3+ ions were analyzed by square wave anodic stripping voltammetry. By combining a protective layer and wet sample digestion, the heavy metal ions in soil samples could be analyzed. Correlation coefficients between the values obtained by this method and those by a conventional method was 0.982 (Pb2+), 0.969 (Cd2+), and 0.936 (As3+).","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"19 1","pages":"1425-1428"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of Heavy Metal Ions in Real Samples using a Concentrator Device with a Super-Hydrophobic Surface\",\"authors\":\"I. Yanagimachi, N. Nashida, K. Iwasa, H. Suzuki\",\"doi\":\"10.1109/SENSOR.2007.4300411\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Heavy metal ions in soil samples were analyzed by a novel method based on evaporative concentration. The detector chip had a microelectrode array as a working electrode and a Ag/AgCl reference electrode surrounded by a super-hydrophobic layer formed with polytetrafluoroethylene (PTFE) beads. A sample droplet formed on the electrode area was shrunk to concentrate the solution. Cd2+ , Pb2+ , and As3+ ions were analyzed by square wave anodic stripping voltammetry. By combining a protective layer and wet sample digestion, the heavy metal ions in soil samples could be analyzed. Correlation coefficients between the values obtained by this method and those by a conventional method was 0.982 (Pb2+), 0.969 (Cd2+), and 0.936 (As3+).\",\"PeriodicalId\":23295,\"journal\":{\"name\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"volume\":\"19 1\",\"pages\":\"1425-1428\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-09-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2007.4300411\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2007.4300411","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用蒸发浓度法对土壤样品中的重金属离子进行了分析。该检测芯片采用微电极阵列作为工作电极,Ag/AgCl参比电极被聚四氟乙烯(PTFE)微珠形成的超疏水层包裹。在电极区域形成的样品液滴被缩小以浓缩溶液。采用方波阳极溶出伏安法分析Cd2+、Pb2+和As3+离子。采用保护层与湿消解相结合的方法,可以对土壤样品中的重金属离子进行分析。与常规方法的相关系数分别为0.982 (Pb2+)、0.969 (Cd2+)和0.936 (As3+)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of Heavy Metal Ions in Real Samples using a Concentrator Device with a Super-Hydrophobic Surface
Heavy metal ions in soil samples were analyzed by a novel method based on evaporative concentration. The detector chip had a microelectrode array as a working electrode and a Ag/AgCl reference electrode surrounded by a super-hydrophobic layer formed with polytetrafluoroethylene (PTFE) beads. A sample droplet formed on the electrode area was shrunk to concentrate the solution. Cd2+ , Pb2+ , and As3+ ions were analyzed by square wave anodic stripping voltammetry. By combining a protective layer and wet sample digestion, the heavy metal ions in soil samples could be analyzed. Correlation coefficients between the values obtained by this method and those by a conventional method was 0.982 (Pb2+), 0.969 (Cd2+), and 0.936 (As3+).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Biaxially Stretchable Interconnect with Liquid Alloy Joints on Flexible Substrate Analysis of Heavy Metal Ions in Real Samples using a Concentrator Device with a Super-Hydrophobic Surface Sliding Contact Micro-Bearing for Nano-Precision Sensing and Positioning Self-Sensing Quartz-Crystal Cantilever for Nanometric Sensing Fabrication and Characterization of a Hydrogen Sensor Based on Palladium Nanowires
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1