Ih Lee, J. Jung, S. Lee, J. Lee, R. Lee, H. Park, J. Kang, Y. Chae
{"title":"摘要P3-03-29:不提取RNA的直接逆转录环介导等温扩增法(direct RT-LAMP)检测早期乳腺癌淋巴结转移的评价","authors":"Ih Lee, J. Jung, S. Lee, J. Lee, R. Lee, H. Park, J. Kang, Y. Chae","doi":"10.1158/1538-7445.SABCS18-P3-03-29","DOIUrl":null,"url":null,"abstract":"Backgroud: The detection of lymph node metastasis by reverse transcription loop-mediated isothermal amplification method (RT-LAMP) had been studied previously. Even though, RT-LAMP method provides improved performance compared to intraoperative histology sentinel lymph node (SLN) evaluation, direct RT-LAMP method without RNA extraction can be more efficient and easily accessible process. Therefore, we evaluated the performance and efficacy of a direct reverse transcription loop-mediated isothermal amplification (direct RT-LAMP) assay for visual detection of CK19 , CK20 , and CEA mRNAs to identify lymph node metastasis in patients with early breast cancer. Methods: A total of 92 lymph nodes dissected from 40 patients with breast cancer were collected at the breast cancer center of Kyungpook National University Chilgok Hospital between November 2015 and February 2016. All of the samples were analyzed by direct RT-LAMP assay and routine histopathology examination. Cutoff values to distinguish metastasis and nonmetasis were determined by measuring cytokerain 19 (CK19) mRNA in histopathologically positive and negative lymph node using direct RT-LAMP. Results: We set the cutoff value of direct RT-LAMP assay for CK 19 mRNA at 1ng to distinguish status of LN metastasis. The sensitivity and specificity of the RT-LAMP assay were 85.7% and 100%, respectively. The positive predictive value and negative predictive value were 100% and 94.4%. Conclusion: Direct RT-LAMP assay can allow detection of SLN metastasis in breast cancer patients intraoperatively with a good sensitivity through cost-effective and time–saving manner. Citation Format: Lee IH, Jung J, Lee S, Lee J, Lee RK, Park H, Jung J, Kang J, Chae Y. Evaluation of a direct reverse transcription loop-mediated isothermal amplification method without RNA extraction (direct RT-LAMP) for the detection of lymph node metastasis in early breast cancer [abstract]. In: Proceedings of the 2018 San Antonio Breast Cancer Symposium; 2018 Dec 4-8; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2019;79(4 Suppl):Abstract nr P3-03-29.","PeriodicalId":20307,"journal":{"name":"Poster Session Abstracts","volume":"3 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Abstract P3-03-29: Evaluation of a direct reverse transcription loop-mediated isothermal amplification method without RNA extraction (direct RT-LAMP) for the detection of lymph node metastasis in early breast cancer\",\"authors\":\"Ih Lee, J. Jung, S. Lee, J. Lee, R. Lee, H. Park, J. Kang, Y. Chae\",\"doi\":\"10.1158/1538-7445.SABCS18-P3-03-29\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Backgroud: The detection of lymph node metastasis by reverse transcription loop-mediated isothermal amplification method (RT-LAMP) had been studied previously. Even though, RT-LAMP method provides improved performance compared to intraoperative histology sentinel lymph node (SLN) evaluation, direct RT-LAMP method without RNA extraction can be more efficient and easily accessible process. Therefore, we evaluated the performance and efficacy of a direct reverse transcription loop-mediated isothermal amplification (direct RT-LAMP) assay for visual detection of CK19 , CK20 , and CEA mRNAs to identify lymph node metastasis in patients with early breast cancer. Methods: A total of 92 lymph nodes dissected from 40 patients with breast cancer were collected at the breast cancer center of Kyungpook National University Chilgok Hospital between November 2015 and February 2016. All of the samples were analyzed by direct RT-LAMP assay and routine histopathology examination. Cutoff values to distinguish metastasis and nonmetasis were determined by measuring cytokerain 19 (CK19) mRNA in histopathologically positive and negative lymph node using direct RT-LAMP. Results: We set the cutoff value of direct RT-LAMP assay for CK 19 mRNA at 1ng to distinguish status of LN metastasis. The sensitivity and specificity of the RT-LAMP assay were 85.7% and 100%, respectively. The positive predictive value and negative predictive value were 100% and 94.4%. Conclusion: Direct RT-LAMP assay can allow detection of SLN metastasis in breast cancer patients intraoperatively with a good sensitivity through cost-effective and time–saving manner. Citation Format: Lee IH, Jung J, Lee S, Lee J, Lee RK, Park H, Jung J, Kang J, Chae Y. Evaluation of a direct reverse transcription loop-mediated isothermal amplification method without RNA extraction (direct RT-LAMP) for the detection of lymph node metastasis in early breast cancer [abstract]. In: Proceedings of the 2018 San Antonio Breast Cancer Symposium; 2018 Dec 4-8; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2019;79(4 Suppl):Abstract nr P3-03-29.\",\"PeriodicalId\":20307,\"journal\":{\"name\":\"Poster Session Abstracts\",\"volume\":\"3 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Poster Session Abstracts\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1158/1538-7445.SABCS18-P3-03-29\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Poster Session Abstracts","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1158/1538-7445.SABCS18-P3-03-29","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
背景:逆转录环介导的等温扩增法(RT-LAMP)检测淋巴结转移已有研究。尽管与术中前哨淋巴结(SLN)组织学评估相比,RT-LAMP方法提供了更好的性能,但无需RNA提取的直接RT-LAMP方法更有效,更容易获得。因此,我们评估了直接逆转录环介导的等温扩增(direct RT-LAMP)检测CK19、CK20和CEA mrna的性能和有效性,以识别早期乳腺癌患者的淋巴结转移。方法:收集2015年11月- 2016年2月在庆北大学赤谷医院乳腺癌中心共40例乳腺癌患者的92个淋巴结。所有样本均采用直接RT-LAMP法和常规组织病理学检查。通过直接RT-LAMP检测组织病理阳性和阴性淋巴结的细胞角蛋白19 (CK19) mRNA,确定转移和非转移的截止值。结果:我们将直接RT-LAMP检测CK 19 mRNA的截止值设定为1ng,以区分LN转移状态。RT-LAMP检测的灵敏度和特异性分别为85.7%和100%。阳性预测值为100%,阴性预测值为94.4%。结论:直接RT-LAMP法可用于乳腺癌患者术中SLN转移的检测,且具有较好的敏感性,成本低,省时。引用本文:Lee IH, Jung J, Lee S, Lee J, Lee RK, Park H, Jung J, Kang J, Chae y。直接逆转录环介导的等温扩增法(direct RT-LAMP)检测早期乳腺癌淋巴结转移的评价[摘要]。2018年圣安东尼奥乳腺癌研讨会论文集;2018年12月4-8日;费城(PA): AACR;中国癌症杂志,2019;79(4增刊):P3-03-29。
Abstract P3-03-29: Evaluation of a direct reverse transcription loop-mediated isothermal amplification method without RNA extraction (direct RT-LAMP) for the detection of lymph node metastasis in early breast cancer
Backgroud: The detection of lymph node metastasis by reverse transcription loop-mediated isothermal amplification method (RT-LAMP) had been studied previously. Even though, RT-LAMP method provides improved performance compared to intraoperative histology sentinel lymph node (SLN) evaluation, direct RT-LAMP method without RNA extraction can be more efficient and easily accessible process. Therefore, we evaluated the performance and efficacy of a direct reverse transcription loop-mediated isothermal amplification (direct RT-LAMP) assay for visual detection of CK19 , CK20 , and CEA mRNAs to identify lymph node metastasis in patients with early breast cancer. Methods: A total of 92 lymph nodes dissected from 40 patients with breast cancer were collected at the breast cancer center of Kyungpook National University Chilgok Hospital between November 2015 and February 2016. All of the samples were analyzed by direct RT-LAMP assay and routine histopathology examination. Cutoff values to distinguish metastasis and nonmetasis were determined by measuring cytokerain 19 (CK19) mRNA in histopathologically positive and negative lymph node using direct RT-LAMP. Results: We set the cutoff value of direct RT-LAMP assay for CK 19 mRNA at 1ng to distinguish status of LN metastasis. The sensitivity and specificity of the RT-LAMP assay were 85.7% and 100%, respectively. The positive predictive value and negative predictive value were 100% and 94.4%. Conclusion: Direct RT-LAMP assay can allow detection of SLN metastasis in breast cancer patients intraoperatively with a good sensitivity through cost-effective and time–saving manner. Citation Format: Lee IH, Jung J, Lee S, Lee J, Lee RK, Park H, Jung J, Kang J, Chae Y. Evaluation of a direct reverse transcription loop-mediated isothermal amplification method without RNA extraction (direct RT-LAMP) for the detection of lymph node metastasis in early breast cancer [abstract]. In: Proceedings of the 2018 San Antonio Breast Cancer Symposium; 2018 Dec 4-8; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2019;79(4 Suppl):Abstract nr P3-03-29.