A. Khilov, V.A. Shishkova, E. Sergeeva, D. Kurakina, M. Kirillin
{"title":"用于光动力治疗荧光监测的生物组织琼脂幻影","authors":"A. Khilov, V.A. Shishkova, E. Sergeeva, D. Kurakina, M. Kirillin","doi":"10.1070/qel17967","DOIUrl":null,"url":null,"abstract":"An approach to fabricating agar phantoms mimicking spectral optical properties of biological tissues with fluorescent inclusions is proposed, which allows one to imitate the problem of optical visualisation of superficial biological tissues after the administration of a chlorin-based photosensitiser. The different arrangement of a fluorescent layer within a phantom makes it possible to simulate biological tissue in the cases of both topical application and intravenous injection of a photosensitiser. It is shown that absorption and scattering spectra of phantoms are in good agreement with the spectra of real biological tissues in the wavelength range of 500-800 nm. Changes in spectra of absorption and scattering coefficients of phantoms, as well as in their fluorescent properties induced by the addition of a fluorescent marker (chlorinbased photosensitiser) are demonstrated.","PeriodicalId":20775,"journal":{"name":"Quantum Electronics","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Agar phantoms of biological tissue for fluorescence monitoring of photodynamic therapy\",\"authors\":\"A. Khilov, V.A. Shishkova, E. Sergeeva, D. Kurakina, M. Kirillin\",\"doi\":\"10.1070/qel17967\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An approach to fabricating agar phantoms mimicking spectral optical properties of biological tissues with fluorescent inclusions is proposed, which allows one to imitate the problem of optical visualisation of superficial biological tissues after the administration of a chlorin-based photosensitiser. The different arrangement of a fluorescent layer within a phantom makes it possible to simulate biological tissue in the cases of both topical application and intravenous injection of a photosensitiser. It is shown that absorption and scattering spectra of phantoms are in good agreement with the spectra of real biological tissues in the wavelength range of 500-800 nm. Changes in spectra of absorption and scattering coefficients of phantoms, as well as in their fluorescent properties induced by the addition of a fluorescent marker (chlorinbased photosensitiser) are demonstrated.\",\"PeriodicalId\":20775,\"journal\":{\"name\":\"Quantum Electronics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Quantum Electronics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1070/qel17967\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quantum Electronics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1070/qel17967","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
Agar phantoms of biological tissue for fluorescence monitoring of photodynamic therapy
An approach to fabricating agar phantoms mimicking spectral optical properties of biological tissues with fluorescent inclusions is proposed, which allows one to imitate the problem of optical visualisation of superficial biological tissues after the administration of a chlorin-based photosensitiser. The different arrangement of a fluorescent layer within a phantom makes it possible to simulate biological tissue in the cases of both topical application and intravenous injection of a photosensitiser. It is shown that absorption and scattering spectra of phantoms are in good agreement with the spectra of real biological tissues in the wavelength range of 500-800 nm. Changes in spectra of absorption and scattering coefficients of phantoms, as well as in their fluorescent properties induced by the addition of a fluorescent marker (chlorinbased photosensitiser) are demonstrated.
期刊介绍:
Quantum Electronics covers the following principal headings
Letters
Lasers
Active Media
Interaction of Laser Radiation with Matter
Laser Plasma
Nonlinear Optical Phenomena
Nanotechnologies
Quantum Electronic Devices
Optical Processing of Information
Fiber and Integrated Optics
Laser Applications in Technology and Metrology, Biology and Medicine.