聚二甲基硅氧烷(PDMS)在吸塑试验中用线力模型表征键合强度

Yen-Wen Lu, Po-Ting Lin, C. Pai
{"title":"聚二甲基硅氧烷(PDMS)在吸塑试验中用线力模型表征键合强度","authors":"Yen-Wen Lu, Po-Ting Lin, C. Pai","doi":"10.1109/SENSOR.2007.4300578","DOIUrl":null,"url":null,"abstract":"A methodology characterizing the strength of PDMS bonding has been proposed. This method employs a blister test to measure and a line force model to describe the bonding strength. The blister test provides us a close approximation to the bonding failure modes under field-used situations. The line force model is a general means to study the bonding strength. A series of the blister tests on PDMS samples have been conducted. The effects of sample size and structured surface on the bonding strength have been examined.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Polydimethylsiloxane (PDMS) Bonding Strength Characterization by a Line Force Model in Blister Tests\",\"authors\":\"Yen-Wen Lu, Po-Ting Lin, C. Pai\",\"doi\":\"10.1109/SENSOR.2007.4300578\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A methodology characterizing the strength of PDMS bonding has been proposed. This method employs a blister test to measure and a line force model to describe the bonding strength. The blister test provides us a close approximation to the bonding failure modes under field-used situations. The line force model is a general means to study the bonding strength. A series of the blister tests on PDMS samples have been conducted. The effects of sample size and structured surface on the bonding strength have been examined.\",\"PeriodicalId\":23295,\"journal\":{\"name\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2007.4300578\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2007.4300578","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

提出了一种表征PDMS键合强度的方法。该方法采用吸塑试验测量,线力模型描述粘接强度。泡罩试验为我们提供了现场使用情况下粘结破坏模式的近似结果。线力模型是研究粘接强度的常用方法。在PDMS样本上进行了一系列水泡测试。研究了样品尺寸和结构表面对结合强度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Polydimethylsiloxane (PDMS) Bonding Strength Characterization by a Line Force Model in Blister Tests
A methodology characterizing the strength of PDMS bonding has been proposed. This method employs a blister test to measure and a line force model to describe the bonding strength. The blister test provides us a close approximation to the bonding failure modes under field-used situations. The line force model is a general means to study the bonding strength. A series of the blister tests on PDMS samples have been conducted. The effects of sample size and structured surface on the bonding strength have been examined.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Biaxially Stretchable Interconnect with Liquid Alloy Joints on Flexible Substrate Analysis of Heavy Metal Ions in Real Samples using a Concentrator Device with a Super-Hydrophobic Surface Sliding Contact Micro-Bearing for Nano-Precision Sensing and Positioning Self-Sensing Quartz-Crystal Cantilever for Nanometric Sensing Fabrication and Characterization of a Hydrogen Sensor Based on Palladium Nanowires
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1