双弯曲悬臂梁对称和非对称载荷对前段的影响:体外研究

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Open Dentistry Journal Pub Date : 2022-03-29 DOI:10.3390/dj10040052
M. Bilińska, M. Dalstra
{"title":"双弯曲悬臂梁对称和非对称载荷对前段的影响:体外研究","authors":"M. Bilińska, M. Dalstra","doi":"10.3390/dj10040052","DOIUrl":null,"url":null,"abstract":"Cantilevers generate statically determined force systems. The frontal segment loading with symmetric and asymmetric cantilevers in a three-piece intrusion base arch can be used to correct midline asymmetry. Three types of 0.017″ × 0.025″ beta-titanium cantilevers: tip-back (TB), deep curve (DC), utility arch (UA) were tested on typodonts simulating intrusion of the maxillary anterior segment. Typodonts with symmetric and asymmetric cantilevers were scanned with intraoral scanner (3Shape, TRIOS, Copenhagen, Denmark) before (T0) and after (T1) the experiment, scans were superimposed using Mimics software (Materialise, Leuven, Belgium). Data were analysed with qualitative analysis. All cantilevers generated vertical and horizontal forces. For symmetric design, the DC and TB displayed intrusive force with retrusive component, UA intrusion and protrusion. The asymmetric cantilevers produced transverse displacement of anterior segment. DC created lateral, UA medial force, the anterior segment displacement was consistent with the used configuration. The movement of an anterior segment with TB is smaller compared to DC and UA. Symmetric cantilevers configurations can achieve simultaneous intrusion and retrusion or protrusion of the anterior segment. The asymmetric design with transversal force can clinically aid the correction of midline discrepancies. The effect of the cantilever configuration on delivered force direction was confirmed.","PeriodicalId":47284,"journal":{"name":"Open Dentistry Journal","volume":"1 1","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2022-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"The Effect of Symmetric and Asymmetric Loading of Frontal Segment with Two Curved Cantilevers: An In Vitro Study\",\"authors\":\"M. Bilińska, M. Dalstra\",\"doi\":\"10.3390/dj10040052\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cantilevers generate statically determined force systems. The frontal segment loading with symmetric and asymmetric cantilevers in a three-piece intrusion base arch can be used to correct midline asymmetry. Three types of 0.017″ × 0.025″ beta-titanium cantilevers: tip-back (TB), deep curve (DC), utility arch (UA) were tested on typodonts simulating intrusion of the maxillary anterior segment. Typodonts with symmetric and asymmetric cantilevers were scanned with intraoral scanner (3Shape, TRIOS, Copenhagen, Denmark) before (T0) and after (T1) the experiment, scans were superimposed using Mimics software (Materialise, Leuven, Belgium). Data were analysed with qualitative analysis. All cantilevers generated vertical and horizontal forces. For symmetric design, the DC and TB displayed intrusive force with retrusive component, UA intrusion and protrusion. The asymmetric cantilevers produced transverse displacement of anterior segment. DC created lateral, UA medial force, the anterior segment displacement was consistent with the used configuration. The movement of an anterior segment with TB is smaller compared to DC and UA. Symmetric cantilevers configurations can achieve simultaneous intrusion and retrusion or protrusion of the anterior segment. The asymmetric design with transversal force can clinically aid the correction of midline discrepancies. The effect of the cantilever configuration on delivered force direction was confirmed.\",\"PeriodicalId\":47284,\"journal\":{\"name\":\"Open Dentistry Journal\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2022-03-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/dj10040052\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj10040052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2

摘要

悬臂梁产生静定力系统。在三件式侵入式基础拱中,采用对称悬臂梁和非对称悬臂梁的前段加载可以纠正中线不对称。采用0.017″× 0.025″β -钛悬臂梁三种类型:后倾型(TB)、深弯型(DC)、实用弓型(UA)在模拟上颌前段侵入的压型牙上进行测试。在实验前(T0)和实验后(T1),使用Mimics软件(Materialise, Leuven, Belgium)对对称和非对称悬臂的Typodonts进行口腔内扫描仪(3Shape, TRIOS, Copenhagen, Denmark)扫描。对资料进行定性分析。所有悬臂都产生垂直和水平力。在对称设计下,DC和TB表现为具有后退分量的侵入力,UA表现为侵入和突出分量。不对称悬臂梁引起前节段横向位移。DC产生外侧力,UA产生内侧力,前段移位与使用的构型一致。与DC和UA相比,TB前节的运动较小。对称悬臂结构可以同时实现前段的侵入和后缩或突出。具有横向力的不对称设计在临床上有助于中线差异的矫正。验证了悬臂结构对传递力方向的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Effect of Symmetric and Asymmetric Loading of Frontal Segment with Two Curved Cantilevers: An In Vitro Study
Cantilevers generate statically determined force systems. The frontal segment loading with symmetric and asymmetric cantilevers in a three-piece intrusion base arch can be used to correct midline asymmetry. Three types of 0.017″ × 0.025″ beta-titanium cantilevers: tip-back (TB), deep curve (DC), utility arch (UA) were tested on typodonts simulating intrusion of the maxillary anterior segment. Typodonts with symmetric and asymmetric cantilevers were scanned with intraoral scanner (3Shape, TRIOS, Copenhagen, Denmark) before (T0) and after (T1) the experiment, scans were superimposed using Mimics software (Materialise, Leuven, Belgium). Data were analysed with qualitative analysis. All cantilevers generated vertical and horizontal forces. For symmetric design, the DC and TB displayed intrusive force with retrusive component, UA intrusion and protrusion. The asymmetric cantilevers produced transverse displacement of anterior segment. DC created lateral, UA medial force, the anterior segment displacement was consistent with the used configuration. The movement of an anterior segment with TB is smaller compared to DC and UA. Symmetric cantilevers configurations can achieve simultaneous intrusion and retrusion or protrusion of the anterior segment. The asymmetric design with transversal force can clinically aid the correction of midline discrepancies. The effect of the cantilever configuration on delivered force direction was confirmed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Open Dentistry Journal
Open Dentistry Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.00
自引率
0.00%
发文量
86
期刊最新文献
Caries Experience and Treatment Needs in Urban and Rural Environments in School-Age Children from Three Provinces of Ecuador: A Cross-Sectional Study Cannabidiol in Dentistry: A Scoping Review Effectiveness of 38% Silver Diamine Fluoride in Reducing Dentine Hypersensitivity on Exposed Root Surface in Older Chinese Adults: Study Protocol for a Randomised Double-Blind Study Challenges and Opportunities for Dental Education from COVID-19 An Analysis of Different Techniques Used to Seal Post-Extractive Sites—A Preliminary Report
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1