N. Khalesi, Farnoosh Seirafianpour, R. Hoseini, H. Otukesh, N. Rahimzadeh, S. Nakhaie, G. Gohardehi, P. Mohaghegh
{"title":"基于胱抑素C配方估算新生儿肾小球滤过率","authors":"N. Khalesi, Farnoosh Seirafianpour, R. Hoseini, H. Otukesh, N. Rahimzadeh, S. Nakhaie, G. Gohardehi, P. Mohaghegh","doi":"10.22038/IJN.2021.43684.1727","DOIUrl":null,"url":null,"abstract":"Background: Glomerular filtration rate (GFR) is the best indicator to assess renal function; however, it is difficult to perform it, especially in neonates. Serum creatinine is the most commonly used marker of GFR; nevertheless, it has some limitations since it can be affected by factors other than renal function. Cystatin C, another endogenous marker used to estimate GFR, is not affected by non-renal factors. The results of some studies suggest that serum cystatin C levels are more accurate tests of kidney function than serum creatinine levels. This study aimed to estimate GFR with cystatin C-based formulas among neonates and determine the correlations between these methods and the Schwartz formula. Methods: The population of this research consisted of 99 neonates whose serum creatinine and cystatin C levels were measured concurrently. Moreover, the glomerular filtration rate was estimated using the Schwartz formula and 14 cystatin C-based formulas separately. Results: Based on the findings, all GFR values based on cystatin C formulas correlated significantly with each other (p 0.05). The only cystatin C formula that yielded values correlating with the Schwartz formula was CysCrEq, which used serum cystatin C and creatinine concomitantly. Conclusion: It can be concluded that since all GFR values based on cystatin C correlated significantly and cystatin Cwasindependent of non-renal factors, cystatin C reflected the real GFR more accurately than serum creatinine. Nonetheless, further studies with gold standard techniques are required to verify the usefulness of cystatin C-based formulas.","PeriodicalId":14584,"journal":{"name":"Iranian Journal of Neonatology IJN","volume":"14 1","pages":"21-26"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Glomerular Filtration Rate Estimation Based on Cystatin C Formulas among Neonates\",\"authors\":\"N. Khalesi, Farnoosh Seirafianpour, R. Hoseini, H. Otukesh, N. Rahimzadeh, S. Nakhaie, G. Gohardehi, P. Mohaghegh\",\"doi\":\"10.22038/IJN.2021.43684.1727\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Glomerular filtration rate (GFR) is the best indicator to assess renal function; however, it is difficult to perform it, especially in neonates. Serum creatinine is the most commonly used marker of GFR; nevertheless, it has some limitations since it can be affected by factors other than renal function. Cystatin C, another endogenous marker used to estimate GFR, is not affected by non-renal factors. The results of some studies suggest that serum cystatin C levels are more accurate tests of kidney function than serum creatinine levels. This study aimed to estimate GFR with cystatin C-based formulas among neonates and determine the correlations between these methods and the Schwartz formula. Methods: The population of this research consisted of 99 neonates whose serum creatinine and cystatin C levels were measured concurrently. Moreover, the glomerular filtration rate was estimated using the Schwartz formula and 14 cystatin C-based formulas separately. Results: Based on the findings, all GFR values based on cystatin C formulas correlated significantly with each other (p 0.05). The only cystatin C formula that yielded values correlating with the Schwartz formula was CysCrEq, which used serum cystatin C and creatinine concomitantly. Conclusion: It can be concluded that since all GFR values based on cystatin C correlated significantly and cystatin Cwasindependent of non-renal factors, cystatin C reflected the real GFR more accurately than serum creatinine. Nonetheless, further studies with gold standard techniques are required to verify the usefulness of cystatin C-based formulas.\",\"PeriodicalId\":14584,\"journal\":{\"name\":\"Iranian Journal of Neonatology IJN\",\"volume\":\"14 1\",\"pages\":\"21-26\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Journal of Neonatology IJN\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22038/IJN.2021.43684.1727\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Neonatology IJN","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/IJN.2021.43684.1727","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Glomerular Filtration Rate Estimation Based on Cystatin C Formulas among Neonates
Background: Glomerular filtration rate (GFR) is the best indicator to assess renal function; however, it is difficult to perform it, especially in neonates. Serum creatinine is the most commonly used marker of GFR; nevertheless, it has some limitations since it can be affected by factors other than renal function. Cystatin C, another endogenous marker used to estimate GFR, is not affected by non-renal factors. The results of some studies suggest that serum cystatin C levels are more accurate tests of kidney function than serum creatinine levels. This study aimed to estimate GFR with cystatin C-based formulas among neonates and determine the correlations between these methods and the Schwartz formula. Methods: The population of this research consisted of 99 neonates whose serum creatinine and cystatin C levels were measured concurrently. Moreover, the glomerular filtration rate was estimated using the Schwartz formula and 14 cystatin C-based formulas separately. Results: Based on the findings, all GFR values based on cystatin C formulas correlated significantly with each other (p 0.05). The only cystatin C formula that yielded values correlating with the Schwartz formula was CysCrEq, which used serum cystatin C and creatinine concomitantly. Conclusion: It can be concluded that since all GFR values based on cystatin C correlated significantly and cystatin Cwasindependent of non-renal factors, cystatin C reflected the real GFR more accurately than serum creatinine. Nonetheless, further studies with gold standard techniques are required to verify the usefulness of cystatin C-based formulas.