Y. Endo, Masaharu Takahashi, K. Ito, K. Saito, Soichi Watanabe
{"title":"手机对植入式心脏起搏器周围SAR的实验评价","authors":"Y. Endo, Masaharu Takahashi, K. Ito, K. Saito, Soichi Watanabe","doi":"10.1145/2093698.2093708","DOIUrl":null,"url":null,"abstract":"Recently, electromagnetic interference (EMI) of an implanted pacemaker with a mobile phone has been investigated. However, there are few studies of specific absorption rate (SAR) around the implanted pacemaker by the mobile phone. In this study, SAR distribution around the pacemaker model embedded into the parallelepiped torso phantom was evaluated experimentally. As a result, characteristic SAR distribution, which is caused by implanted pacemaker, was observed.","PeriodicalId":91990,"journal":{"name":"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental evaluation on SAR around the implanted cardiac pacemaker by mobile phone\",\"authors\":\"Y. Endo, Masaharu Takahashi, K. Ito, K. Saito, Soichi Watanabe\",\"doi\":\"10.1145/2093698.2093708\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, electromagnetic interference (EMI) of an implanted pacemaker with a mobile phone has been investigated. However, there are few studies of specific absorption rate (SAR) around the implanted pacemaker by the mobile phone. In this study, SAR distribution around the pacemaker model embedded into the parallelepiped torso phantom was evaluated experimentally. As a result, characteristic SAR distribution, which is caused by implanted pacemaker, was observed.\",\"PeriodicalId\":91990,\"journal\":{\"name\":\"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/2093698.2093708\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2093698.2093708","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental evaluation on SAR around the implanted cardiac pacemaker by mobile phone
Recently, electromagnetic interference (EMI) of an implanted pacemaker with a mobile phone has been investigated. However, there are few studies of specific absorption rate (SAR) around the implanted pacemaker by the mobile phone. In this study, SAR distribution around the pacemaker model embedded into the parallelepiped torso phantom was evaluated experimentally. As a result, characteristic SAR distribution, which is caused by implanted pacemaker, was observed.