骨质疏松症后向散射系数的临床评价

P. Laugier, P. Giat, C. Chappard, C. Roux, G. Berger
{"title":"骨质疏松症后向散射系数的临床评价","authors":"P. Laugier, P. Giat, C. Chappard, C. Roux, G. Berger","doi":"10.1109/ULTSYM.1997.661772","DOIUrl":null,"url":null,"abstract":"Current commercial ultrasound \"bone densitometers\" process only the through-transmitted signals while failing to extract additional information contained in the scattered signals. This work was conducted to investigate the clinical interest of a backscatter ultrasound technique for bone characterization in 24 healthy premenopausal (group N), 24 postmenopausal (group PM), and 13 osteoporotic patients with fractures (group O). Pulse-echo measurements of the backscatter power were performed at the calcaneus (heel bone) using an ultrasound bone imaging scanner. The pulse-echo waveforms backscattered by the internal trabecular micro-architecture were recorded to compute the integrated backscatter coefficient (BUB, dB) in the frequency range 200-600 kHz. BUB was compared to the slope of the frequency-dependent attenuation (BUA, dB/MHz) derived from signals transmitted through the bone and to bone mineral density. Measurements were averaged in an operator-independent automatic ROI. The short-term reproducibility was 1.4%, and 3.5% for BUA, and BUB respectively. Femoral bone mass density (BMD) was measured in all subjects and calcaneal BMD was measured in a subset of 30 patients. The correlation between ultrasound and calcaneal BMD was moderate for BUB (r=0.55, p<10/sup -3/) and strong for BUA (r=0.82, p<10/sup -4/). Significant differences were found in ultrasound parameters and BMD between fracture and non-fracture groups. There was a significant difference in BMD and ultrasound parameters between young normal controls and healthy post-menopausal women. In summary, reflection ultrasound appears to be promising in osteoporosis and larger studies are clearly warranted.","PeriodicalId":6369,"journal":{"name":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","volume":"33 1","pages":"1101-1104 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"35","resultStr":"{\"title\":\"Clinical assessment of the backscatter coefficient in osteoporosis\",\"authors\":\"P. Laugier, P. Giat, C. Chappard, C. Roux, G. Berger\",\"doi\":\"10.1109/ULTSYM.1997.661772\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Current commercial ultrasound \\\"bone densitometers\\\" process only the through-transmitted signals while failing to extract additional information contained in the scattered signals. This work was conducted to investigate the clinical interest of a backscatter ultrasound technique for bone characterization in 24 healthy premenopausal (group N), 24 postmenopausal (group PM), and 13 osteoporotic patients with fractures (group O). Pulse-echo measurements of the backscatter power were performed at the calcaneus (heel bone) using an ultrasound bone imaging scanner. The pulse-echo waveforms backscattered by the internal trabecular micro-architecture were recorded to compute the integrated backscatter coefficient (BUB, dB) in the frequency range 200-600 kHz. BUB was compared to the slope of the frequency-dependent attenuation (BUA, dB/MHz) derived from signals transmitted through the bone and to bone mineral density. Measurements were averaged in an operator-independent automatic ROI. The short-term reproducibility was 1.4%, and 3.5% for BUA, and BUB respectively. Femoral bone mass density (BMD) was measured in all subjects and calcaneal BMD was measured in a subset of 30 patients. The correlation between ultrasound and calcaneal BMD was moderate for BUB (r=0.55, p<10/sup -3/) and strong for BUA (r=0.82, p<10/sup -4/). Significant differences were found in ultrasound parameters and BMD between fracture and non-fracture groups. There was a significant difference in BMD and ultrasound parameters between young normal controls and healthy post-menopausal women. In summary, reflection ultrasound appears to be promising in osteoporosis and larger studies are clearly warranted.\",\"PeriodicalId\":6369,\"journal\":{\"name\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"volume\":\"33 1\",\"pages\":\"1101-1104 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"35\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1997.661772\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1997.661772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 35

摘要

目前的商用超声“骨密度仪”只处理通过传输的信号,而不能提取散射信号中包含的附加信息。本研究对24名健康绝经前(N组)、24名绝经后(PM组)和13名骨质疏松骨折患者(O组)进行了后向散射超声技术骨表征的临床研究。使用超声骨成像扫描仪对跟骨(跟骨)进行了后向散射功率的脉冲回波测量。记录内部小梁微结构后向散射的脉冲回波波形,计算200 ~ 600 kHz频率范围内的综合后向散射系数(BUB, dB)。将BUB与频率相关衰减(BUA, dB/MHz)的斜率进行比较,该衰减来自于通过骨骼传输的信号和骨矿物质密度。测量结果在独立于操作人员的自动ROI中进行平均。BUA和BUB的短期重复性分别为1.4%和3.5%。测量了所有受试者的股骨骨密度(BMD),并测量了30例患者的跟骨骨密度。超声与跟骨骨密度的相关性在BUB中为中等(r=0.55, p<10/sup -3/),在BUA中为较强(r=0.82, p<10/sup -4/)。骨折组与非骨折组超声参数及骨密度有显著性差异。年轻正常对照和健康绝经后妇女的骨密度和超声参数有显著差异。总之,反射超声似乎在骨质疏松症和更大规模的研究是有希望的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical assessment of the backscatter coefficient in osteoporosis
Current commercial ultrasound "bone densitometers" process only the through-transmitted signals while failing to extract additional information contained in the scattered signals. This work was conducted to investigate the clinical interest of a backscatter ultrasound technique for bone characterization in 24 healthy premenopausal (group N), 24 postmenopausal (group PM), and 13 osteoporotic patients with fractures (group O). Pulse-echo measurements of the backscatter power were performed at the calcaneus (heel bone) using an ultrasound bone imaging scanner. The pulse-echo waveforms backscattered by the internal trabecular micro-architecture were recorded to compute the integrated backscatter coefficient (BUB, dB) in the frequency range 200-600 kHz. BUB was compared to the slope of the frequency-dependent attenuation (BUA, dB/MHz) derived from signals transmitted through the bone and to bone mineral density. Measurements were averaged in an operator-independent automatic ROI. The short-term reproducibility was 1.4%, and 3.5% for BUA, and BUB respectively. Femoral bone mass density (BMD) was measured in all subjects and calcaneal BMD was measured in a subset of 30 patients. The correlation between ultrasound and calcaneal BMD was moderate for BUB (r=0.55, p<10/sup -3/) and strong for BUA (r=0.82, p<10/sup -4/). Significant differences were found in ultrasound parameters and BMD between fracture and non-fracture groups. There was a significant difference in BMD and ultrasound parameters between young normal controls and healthy post-menopausal women. In summary, reflection ultrasound appears to be promising in osteoporosis and larger studies are clearly warranted.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diamond wafer for SAW application High contrast images of defects in food package seals New properties of the SAW gas sensing Electromagnetic acoustic resonance for studying dislocation formation in polycrystalline pure copper during deformation A new design of ultrasonic air-coupled ribbon transducer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1