用修正的Gouy-Stodola方程分析喷射器冷却系统的火用

G. Sachdeva, B. Sharma
{"title":"用修正的Gouy-Stodola方程分析喷射器冷却系统的火用","authors":"G. Sachdeva, B. Sharma","doi":"10.1142/s2010132521500279","DOIUrl":null,"url":null,"abstract":"In this paper, exergy destruction analysis of a heat-assisted ejector cooling system has been carried out using a modified Gouy–Stodola equation. The modified Gouy–Stodola equation provides a more accurate and realistic irreversibility analysis of the system than the conventional Gouy–Stodola formulation. The coefficient of structural bond (CSB) analysis has also been executed to find the component whose operating variables affect the system’s total irreversibility at the most. Exergy analysis revealed that the maximum exergy loss happens in the ejector followed by the generator and condenser. The model predicted 40.84% of total irreversibility in the ejector at the designed conditions. However, total exergy destruction is found to be the most sensitive to the evaporator temperature. The CSB value of 12.97 is obtained in the evaporator using the modified exergy method. The generator appears to be the second sensitive component with the CSB value of 2.42, followed by the condenser with the CSB value of 1.628. The coefficient of performance of the system is found to be 0.18 at the designed conditions. The refrigerant R1234yf is considered in the system.","PeriodicalId":13757,"journal":{"name":"International Journal of Air-conditioning and Refrigeration","volume":"40 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Exergy Analysis of an Ejector Cooling System by Modified Gouy–Stodola Equation\",\"authors\":\"G. Sachdeva, B. Sharma\",\"doi\":\"10.1142/s2010132521500279\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, exergy destruction analysis of a heat-assisted ejector cooling system has been carried out using a modified Gouy–Stodola equation. The modified Gouy–Stodola equation provides a more accurate and realistic irreversibility analysis of the system than the conventional Gouy–Stodola formulation. The coefficient of structural bond (CSB) analysis has also been executed to find the component whose operating variables affect the system’s total irreversibility at the most. Exergy analysis revealed that the maximum exergy loss happens in the ejector followed by the generator and condenser. The model predicted 40.84% of total irreversibility in the ejector at the designed conditions. However, total exergy destruction is found to be the most sensitive to the evaporator temperature. The CSB value of 12.97 is obtained in the evaporator using the modified exergy method. The generator appears to be the second sensitive component with the CSB value of 2.42, followed by the condenser with the CSB value of 1.628. The coefficient of performance of the system is found to be 0.18 at the designed conditions. The refrigerant R1234yf is considered in the system.\",\"PeriodicalId\":13757,\"journal\":{\"name\":\"International Journal of Air-conditioning and Refrigeration\",\"volume\":\"40 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Air-conditioning and Refrigeration\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1142/s2010132521500279\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"THERMODYNAMICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Air-conditioning and Refrigeration","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/s2010132521500279","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"THERMODYNAMICS","Score":null,"Total":0}
引用次数: 1

摘要

本文采用修正的Gouy-Stodola方程对热辅助喷射器冷却系统进行了火用破坏分析。修正后的Gouy-Stodola方程比传统的Gouy-Stodola公式对系统的不可逆性分析更准确、更现实。通过结构键系数(coefficient of structural bond, CSB)分析,找出其运行变量对系统总不可逆性影响最大的组分。火用分析表明,火用损失最大的是喷射器,其次是发电机和冷凝器。该模型预测了设计条件下喷射器总不可逆性的40.84%。然而,发现总火用破坏对蒸发器温度最敏感。采用改进的火用法,蒸发器的CSB值为12.97。发电机似乎是第二个敏感部件,CSB值为2.42,其次是冷凝器,CSB值为1.628。在设计条件下,系统的性能系数为0.18。系统考虑制冷剂为R1234yf。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Exergy Analysis of an Ejector Cooling System by Modified Gouy–Stodola Equation
In this paper, exergy destruction analysis of a heat-assisted ejector cooling system has been carried out using a modified Gouy–Stodola equation. The modified Gouy–Stodola equation provides a more accurate and realistic irreversibility analysis of the system than the conventional Gouy–Stodola formulation. The coefficient of structural bond (CSB) analysis has also been executed to find the component whose operating variables affect the system’s total irreversibility at the most. Exergy analysis revealed that the maximum exergy loss happens in the ejector followed by the generator and condenser. The model predicted 40.84% of total irreversibility in the ejector at the designed conditions. However, total exergy destruction is found to be the most sensitive to the evaporator temperature. The CSB value of 12.97 is obtained in the evaporator using the modified exergy method. The generator appears to be the second sensitive component with the CSB value of 2.42, followed by the condenser with the CSB value of 1.628. The coefficient of performance of the system is found to be 0.18 at the designed conditions. The refrigerant R1234yf is considered in the system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.70
自引率
10.00%
发文量
0
期刊介绍: As the only international journal in the field of air-conditioning and refrigeration in Asia, IJACR reports researches on the equipments for controlling indoor environment and cooling/refrigeration. It includes broad range of applications and underlying theories including fluid dynamics, thermodynamics, heat transfer, and nano/bio-related technologies. In addition, it covers future energy technologies, such as fuel cell, wind turbine, solar cell/heat, geothermal energy and etc.
期刊最新文献
A review on thermochemical seasonal solar energy storage materials and modeling methods Parametric analysis of chiller plant energy consumption in a tropical climate Experimental investigation of ice slurry viscosity Performance enhancement and environmental analysis of vapor compression refrigeration system with dedicated mechanical subcooling Energy analysis of the integration of HRV and direct evaporative cooling for energy efficiency in buildings: a case study in Iraq
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1