使用盛行相量的谐波阻抗评估

D. Serfontein, J. Rens, Gerhard Botha
{"title":"使用盛行相量的谐波阻抗评估","authors":"D. Serfontein, J. Rens, Gerhard Botha","doi":"10.1109/ICHQP.2018.8378872","DOIUrl":null,"url":null,"abstract":"In accordance with the IEC 61000-3-6, the evaluation of the harmonic emissions requires an accurate harmonic impedance representation of the system. However, the assessment of a harmonic impedance is understood to be a very complex problem and that the available methods are not entirely satisfactory. Yet, utilities and other network users are expected to prove compliance to apportioned emission limits. To enable the online assessment of harmonic emissions, this paper proposes the use of prevailing phasors to enable the monitoring of the network's harmonic impedance. The proposed method has been validated using network simulations and practical measurements at a windfarm were used for offline assessments.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"338 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Harmonic impedance assessment using prevailing phasors\",\"authors\":\"D. Serfontein, J. Rens, Gerhard Botha\",\"doi\":\"10.1109/ICHQP.2018.8378872\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In accordance with the IEC 61000-3-6, the evaluation of the harmonic emissions requires an accurate harmonic impedance representation of the system. However, the assessment of a harmonic impedance is understood to be a very complex problem and that the available methods are not entirely satisfactory. Yet, utilities and other network users are expected to prove compliance to apportioned emission limits. To enable the online assessment of harmonic emissions, this paper proposes the use of prevailing phasors to enable the monitoring of the network's harmonic impedance. The proposed method has been validated using network simulations and practical measurements at a windfarm were used for offline assessments.\",\"PeriodicalId\":6506,\"journal\":{\"name\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"volume\":\"338 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2018.8378872\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2018.8378872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

根据IEC 61000-3-6,谐波发射的评估需要系统的精确谐波阻抗表示。然而,谐波阻抗的评估是一个非常复杂的问题,现有的方法并不完全令人满意。然而,公用事业公司和其他电网用户需要证明遵守分配的排放限制。为了能够在线评估谐波发射,本文建议使用主流相量来监测网络的谐波阻抗。该方法已通过网络模拟和风电场的实际测量进行了离线评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Harmonic impedance assessment using prevailing phasors
In accordance with the IEC 61000-3-6, the evaluation of the harmonic emissions requires an accurate harmonic impedance representation of the system. However, the assessment of a harmonic impedance is understood to be a very complex problem and that the available methods are not entirely satisfactory. Yet, utilities and other network users are expected to prove compliance to apportioned emission limits. To enable the online assessment of harmonic emissions, this paper proposes the use of prevailing phasors to enable the monitoring of the network's harmonic impedance. The proposed method has been validated using network simulations and practical measurements at a windfarm were used for offline assessments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Adaptive segmentation and machine learning based potential DR capacity analysis Harmonic resonance risk of massive ultra fast charging station grid integration A general process recommended by CIGRE WG C4.27 for benchmarking power quality performance in transmission systems On the limitations of harmonic modeling with measured inputs - a case study Analysis of replacement from disconnecting switch to circuit breaker for 500 kV line shunt reactor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1