{"title":"日本冲绳根家湾内潮特征及其相关冷却系统","authors":"M. Rouf, E. Nakaza, Ryutarou Kudaka, L. Kotler","doi":"10.2208/JSCEJB.66.157","DOIUrl":null,"url":null,"abstract":"Profiling and mooring measurements were carried out in Genka Bay, Okinawa, Japan to study the characteristics of the internal tidal current and its associated cooling system. The study results show that the depth-averaged current flows nearly parallel to the coastline. There is also an existence of a cross-shore internal tidal current according to the vertical structure of the horizontal current. This current influences on the bottom water temperature transmission from offshore to nearshore bottom water and changes the vertical temperature profile even of nearshore regions and thereby establishes a unique cooling system. Spectra of the baroclinic and bottom water temperature also congruent the internal tide based cooling system in GB.","PeriodicalId":11343,"journal":{"name":"Doboku Gakkai Ronbunshuu B","volume":"23 1","pages":"157-166"},"PeriodicalIF":0.0000,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CHARACTERISTICS OF THE INTERNAL TIDE AND ITS ASSOCIATED COOLING SYSTEM IN GENKA BAY, OKINAWA, JAPAN\",\"authors\":\"M. Rouf, E. Nakaza, Ryutarou Kudaka, L. Kotler\",\"doi\":\"10.2208/JSCEJB.66.157\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Profiling and mooring measurements were carried out in Genka Bay, Okinawa, Japan to study the characteristics of the internal tidal current and its associated cooling system. The study results show that the depth-averaged current flows nearly parallel to the coastline. There is also an existence of a cross-shore internal tidal current according to the vertical structure of the horizontal current. This current influences on the bottom water temperature transmission from offshore to nearshore bottom water and changes the vertical temperature profile even of nearshore regions and thereby establishes a unique cooling system. Spectra of the baroclinic and bottom water temperature also congruent the internal tide based cooling system in GB.\",\"PeriodicalId\":11343,\"journal\":{\"name\":\"Doboku Gakkai Ronbunshuu B\",\"volume\":\"23 1\",\"pages\":\"157-166\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Doboku Gakkai Ronbunshuu B\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2208/JSCEJB.66.157\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Doboku Gakkai Ronbunshuu B","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2208/JSCEJB.66.157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
CHARACTERISTICS OF THE INTERNAL TIDE AND ITS ASSOCIATED COOLING SYSTEM IN GENKA BAY, OKINAWA, JAPAN
Profiling and mooring measurements were carried out in Genka Bay, Okinawa, Japan to study the characteristics of the internal tidal current and its associated cooling system. The study results show that the depth-averaged current flows nearly parallel to the coastline. There is also an existence of a cross-shore internal tidal current according to the vertical structure of the horizontal current. This current influences on the bottom water temperature transmission from offshore to nearshore bottom water and changes the vertical temperature profile even of nearshore regions and thereby establishes a unique cooling system. Spectra of the baroclinic and bottom water temperature also congruent the internal tide based cooling system in GB.