用直流输电和分绕组电力变压器减少短路电流

I. Krakhmalin, A. Chivenkov, Y. Vagapov, A. Anuchin
{"title":"用直流输电和分绕组电力变压器减少短路电流","authors":"I. Krakhmalin, A. Chivenkov, Y. Vagapov, A. Anuchin","doi":"10.1109/UPEC.2019.8893544","DOIUrl":null,"url":null,"abstract":"This paper discusses a new scheme to reduce the level of fault currents in the feeder cable and power transformer windings under short-circuit conditions. The proposed scheme suggests splitting the feeder cable in two cables and connecting it to a network through two rectifier units. Therefore, the split windings of the power transformer are supplied by a six-conductor feeder using unidirectional dc current. Unidirectional magnetic flux produced by the windings are summarised in the transformer core resulting ac flux to ensure a normal transformer operation. The proposed scheme was analysed under short and open-circuit faults. It has been shown that the short-circuit currents in the cable conductors and transformer windings are reduced in 1.41 times in comparison to a conventional scheme.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reduction of Short Circuit Current using DC Transmission and Split-Winding Power Transformer\",\"authors\":\"I. Krakhmalin, A. Chivenkov, Y. Vagapov, A. Anuchin\",\"doi\":\"10.1109/UPEC.2019.8893544\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses a new scheme to reduce the level of fault currents in the feeder cable and power transformer windings under short-circuit conditions. The proposed scheme suggests splitting the feeder cable in two cables and connecting it to a network through two rectifier units. Therefore, the split windings of the power transformer are supplied by a six-conductor feeder using unidirectional dc current. Unidirectional magnetic flux produced by the windings are summarised in the transformer core resulting ac flux to ensure a normal transformer operation. The proposed scheme was analysed under short and open-circuit faults. It has been shown that the short-circuit currents in the cable conductors and transformer windings are reduced in 1.41 times in comparison to a conventional scheme.\",\"PeriodicalId\":6670,\"journal\":{\"name\":\"2019 54th International Universities Power Engineering Conference (UPEC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 54th International Universities Power Engineering Conference (UPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2019.8893544\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 54th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2019.8893544","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文讨论了一种在短路情况下降低馈线电缆和电力变压器绕组故障电流水平的新方案。提出的方案建议将馈线电缆分成两根电缆,并通过两个整流单元连接到网络中。因此,电力变压器的分离绕组由六导体馈线使用单向直流电流供电。绕组产生的单向磁通汇总在变压器铁心中,产生交流磁通,以确保变压器正常运行。对该方案进行了短路和开路故障分析。结果表明,与传统方案相比,电缆导体和变压器绕组中的短路电流减少了1.41倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reduction of Short Circuit Current using DC Transmission and Split-Winding Power Transformer
This paper discusses a new scheme to reduce the level of fault currents in the feeder cable and power transformer windings under short-circuit conditions. The proposed scheme suggests splitting the feeder cable in two cables and connecting it to a network through two rectifier units. Therefore, the split windings of the power transformer are supplied by a six-conductor feeder using unidirectional dc current. Unidirectional magnetic flux produced by the windings are summarised in the transformer core resulting ac flux to ensure a normal transformer operation. The proposed scheme was analysed under short and open-circuit faults. It has been shown that the short-circuit currents in the cable conductors and transformer windings are reduced in 1.41 times in comparison to a conventional scheme.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Universities as a source of grid flexibility: A case study Power Hardware In the Loop and Ancillary Service for Voltage Regulation in Low Voltage Grid Design and Implementation of Hybrid Vehicle using Control of DC Electric Motor Reduction of Short Circuit Current using DC Transmission and Split-Winding Power Transformer Enhanced visualisation of fast frequency phenomena as exhibited in the GB transmission system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1