在线电化学还原为碘化物后反相离子对高效液相色谱-安培检测器超灵敏高选择性测定碘酸盐

Qingwei Jiang, Tao Wang, Gao Li
{"title":"在线电化学还原为碘化物后反相离子对高效液相色谱-安培检测器超灵敏高选择性测定碘酸盐","authors":"Qingwei Jiang, Tao Wang, Gao Li","doi":"10.15586/qas.v15i3.1223","DOIUrl":null,"url":null,"abstract":"We developed an ultrasensitive and highly selective method to quantify iodate (IO3–) in iodized salt and biological samples. In the high-performance liquid chromatography (HPLC) system, IO3– was injected with sampler and reduced to iodide (I–) online using a Coulomb detector (CD) as a pre-column reactor, retained by C18 column with the help of ion pairs, and then determined by an amperometric detector (AD). For analysis of IO3–, several parameters and reactive conditions of Coulomb detector, including applied potential, pH value, and salt concentration, were optimized to obtain the best reduction efficiency. The optimized HPLC–CD-AD method was found to be linear over a wide range of IO3– concentration (0.05–0.25 μg/mL) with appreciable recovery rates (86.90– 94.70%) of quality controls at excellent detection limits (100 pg) and acceptable variability. The analysis of IO3– in actual samples, such as urine of volunteers, iodized salt, and seawater, discovered that the method has high selectivity and little interference. It can be concluded that the proposed method was ultrasensitive and highly selective in the trace detection of IO3.","PeriodicalId":20738,"journal":{"name":"Quality Assurance and Safety of Crops & Foods","volume":"121 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasensitive and highly selective determination of iodate by reversed-phase ion pair HPLC–amperometric detector after online electrochemical reduction to iodide\",\"authors\":\"Qingwei Jiang, Tao Wang, Gao Li\",\"doi\":\"10.15586/qas.v15i3.1223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We developed an ultrasensitive and highly selective method to quantify iodate (IO3–) in iodized salt and biological samples. In the high-performance liquid chromatography (HPLC) system, IO3– was injected with sampler and reduced to iodide (I–) online using a Coulomb detector (CD) as a pre-column reactor, retained by C18 column with the help of ion pairs, and then determined by an amperometric detector (AD). For analysis of IO3–, several parameters and reactive conditions of Coulomb detector, including applied potential, pH value, and salt concentration, were optimized to obtain the best reduction efficiency. The optimized HPLC–CD-AD method was found to be linear over a wide range of IO3– concentration (0.05–0.25 μg/mL) with appreciable recovery rates (86.90– 94.70%) of quality controls at excellent detection limits (100 pg) and acceptable variability. The analysis of IO3– in actual samples, such as urine of volunteers, iodized salt, and seawater, discovered that the method has high selectivity and little interference. It can be concluded that the proposed method was ultrasensitive and highly selective in the trace detection of IO3.\",\"PeriodicalId\":20738,\"journal\":{\"name\":\"Quality Assurance and Safety of Crops & Foods\",\"volume\":\"121 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Quality Assurance and Safety of Crops & Foods\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15586/qas.v15i3.1223\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quality Assurance and Safety of Crops & Foods","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15586/qas.v15i3.1223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们开发了一种超灵敏和高选择性的方法来定量碘化盐和生物样品中的碘酸盐(IO3 -)。在高效液相色谱(HPLC)系统中,采用库仑检测器(CD)作为柱前反应器,将IO3 -注入进样器,在线还原为碘化物(I -),在离子对的帮助下由C18柱保留,再由安培检测器(AD)测定。在分析IO3 -时,对库仑检测器的应用电位、pH值、盐浓度等参数和反应条件进行了优化,以获得最佳还原效率。优化后的HPLC-CD-AD方法在IO3 -浓度(0.05 ~ 0.25 μg/mL)范围内呈良好的线性关系,在良好的检出限(100 pg)和可接受的变异性下,回收率为86.90 ~ 94.70%。通过对志愿者尿液、碘盐、海水等实际样品中碘的分析,发现该方法选择性高,干扰小。结果表明,该方法具有超灵敏、高选择性的痕量碘检测方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultrasensitive and highly selective determination of iodate by reversed-phase ion pair HPLC–amperometric detector after online electrochemical reduction to iodide
We developed an ultrasensitive and highly selective method to quantify iodate (IO3–) in iodized salt and biological samples. In the high-performance liquid chromatography (HPLC) system, IO3– was injected with sampler and reduced to iodide (I–) online using a Coulomb detector (CD) as a pre-column reactor, retained by C18 column with the help of ion pairs, and then determined by an amperometric detector (AD). For analysis of IO3–, several parameters and reactive conditions of Coulomb detector, including applied potential, pH value, and salt concentration, were optimized to obtain the best reduction efficiency. The optimized HPLC–CD-AD method was found to be linear over a wide range of IO3– concentration (0.05–0.25 μg/mL) with appreciable recovery rates (86.90– 94.70%) of quality controls at excellent detection limits (100 pg) and acceptable variability. The analysis of IO3– in actual samples, such as urine of volunteers, iodized salt, and seawater, discovered that the method has high selectivity and little interference. It can be concluded that the proposed method was ultrasensitive and highly selective in the trace detection of IO3.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A beetroot-based beverage produced by adding Lacticaseibacillus paracasei: an optimization study Safety evaluation of genetically modified crops Effect of pullulan active packaging, incorporated with silver nanoparticles, on cholesterol oxidation product concentrations in boiler meat during storage Sustainable rural economy and food security: An integrated approach to the circular agricultural model Mechanistic insight into ochratoxin A adsorption onto the cell wall of Lacticaseibacillus rhamnosus Bm01 and its impact on grape juice quality
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1