一种改进的纯化程序,以提高临床使用90Y的质量

Abmel Xiques Castillo, Keila Isaac Olivé, Edgar Casanova González, Denis Beckford, R. Leyva Montaña, A. Montero Álvarez, Eunice Olivé Álvarez
{"title":"一种改进的纯化程序,以提高临床使用90Y的质量","authors":"Abmel Xiques Castillo, Keila Isaac Olivé, Edgar Casanova González, Denis Beckford, R. Leyva Montaña, A. Montero Álvarez, Eunice Olivé Álvarez","doi":"10.1524/RACT.2009.1666","DOIUrl":null,"url":null,"abstract":"Abstract There is an increasing interest for 90Y for radionuclide therapy. However, radioimmunotherapy, one of the most important applications for 90Y, demands a very high purity product. Obtaining a high quality 90Y is difficult not only because of the complex and time consuming production schemes but also because of the quality control which has challenging tasks like the determination of 90Sr at very low concentrations. The present paper investigates a reported purification procedure for the removal of stable metal trace contaminants from an 90Y solution, seeking for its potential use in the elimination of the radioactive contaminant 90Sr and its fast determination. For this purpose a washing step with HNO3 acid is introduced to elute 90Sr, the order of each acid solution is rearranged to reduce the potential contaminants present in acids and the size of the column is reduced to further optimize the procedure. As a result, an improved purification method is obtained, which allows the removal of both trace metal contaminants and 90Sr from an 90Y solution and the measurement of 90Sr/90Y ratios of the order of 10-7, which are well below the established pharmacopeia limit of 2×10-5.","PeriodicalId":21029,"journal":{"name":"Radiochimica Acta Radiochimica Acta","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"An adapted purification procedure to improve the quality of 90Y for clinical use\",\"authors\":\"Abmel Xiques Castillo, Keila Isaac Olivé, Edgar Casanova González, Denis Beckford, R. Leyva Montaña, A. Montero Álvarez, Eunice Olivé Álvarez\",\"doi\":\"10.1524/RACT.2009.1666\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract There is an increasing interest for 90Y for radionuclide therapy. However, radioimmunotherapy, one of the most important applications for 90Y, demands a very high purity product. Obtaining a high quality 90Y is difficult not only because of the complex and time consuming production schemes but also because of the quality control which has challenging tasks like the determination of 90Sr at very low concentrations. The present paper investigates a reported purification procedure for the removal of stable metal trace contaminants from an 90Y solution, seeking for its potential use in the elimination of the radioactive contaminant 90Sr and its fast determination. For this purpose a washing step with HNO3 acid is introduced to elute 90Sr, the order of each acid solution is rearranged to reduce the potential contaminants present in acids and the size of the column is reduced to further optimize the procedure. As a result, an improved purification method is obtained, which allows the removal of both trace metal contaminants and 90Sr from an 90Y solution and the measurement of 90Sr/90Y ratios of the order of 10-7, which are well below the established pharmacopeia limit of 2×10-5.\",\"PeriodicalId\":21029,\"journal\":{\"name\":\"Radiochimica Acta Radiochimica Acta\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiochimica Acta Radiochimica Acta\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1524/RACT.2009.1666\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiochimica Acta Radiochimica Acta","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1524/RACT.2009.1666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

放射性核素治疗对90Y的兴趣越来越大。然而,放射免疫治疗是90Y最重要的应用之一,需要非常高的纯度产品。获得高质量的90Y是困难的,不仅因为生产方案复杂且耗时,而且因为质量控制具有挑战性的任务,如在极低浓度下测定90Sr。本文研究了一种从90Y溶液中去除稳定金属痕量污染物的净化程序,寻求其在消除放射性污染物90Sr及其快速测定中的潜在用途。为此,引入HNO3酸洗涤步骤来洗脱90Sr,重新排列每个酸溶液的顺序以减少酸中存在的潜在污染物,并减小色谱柱的尺寸以进一步优化程序。结果,获得了一种改进的纯化方法,该方法允许从90Y溶液中去除痕量金属污染物和90Sr,并测量90Sr/90Y的10-7量级的比率,远低于既定药典限值2×10-5。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An adapted purification procedure to improve the quality of 90Y for clinical use
Abstract There is an increasing interest for 90Y for radionuclide therapy. However, radioimmunotherapy, one of the most important applications for 90Y, demands a very high purity product. Obtaining a high quality 90Y is difficult not only because of the complex and time consuming production schemes but also because of the quality control which has challenging tasks like the determination of 90Sr at very low concentrations. The present paper investigates a reported purification procedure for the removal of stable metal trace contaminants from an 90Y solution, seeking for its potential use in the elimination of the radioactive contaminant 90Sr and its fast determination. For this purpose a washing step with HNO3 acid is introduced to elute 90Sr, the order of each acid solution is rearranged to reduce the potential contaminants present in acids and the size of the column is reduced to further optimize the procedure. As a result, an improved purification method is obtained, which allows the removal of both trace metal contaminants and 90Sr from an 90Y solution and the measurement of 90Sr/90Y ratios of the order of 10-7, which are well below the established pharmacopeia limit of 2×10-5.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Uranium, plutonium and neptunium co-recovery with high nitric acid concentration in extraction section by simplified solvent extraction process An adapted purification procedure to improve the quality of 90Y for clinical use Extraction of americium(III) from nitric acid medium by CMPO-TBP extractants in ionic liquid diluent Evaluation of trace elements in chewing tobacco and snuff using instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) Charged particle induced reaction cross section data for production of the emerging medically important positron emitter 64Cu: A comprehensive evaluation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1