9 ~ 150khz频率范围内家用电器对光伏系统的扰动特征

B. Sudiarto, F. Faizal, F. Husnayain, H. Hirsch
{"title":"9 ~ 150khz频率范围内家用电器对光伏系统的扰动特征","authors":"B. Sudiarto, F. Faizal, F. Husnayain, H. Hirsch","doi":"10.15866/iree.v16i5.20275","DOIUrl":null,"url":null,"abstract":"Recently, the renewable energy power generation has been widely used in residential customer by installing PV-rooftop on grid system. The PV-rooftop system uses inverter, which may generate the disturbance in the frequency range of 9-150 kHz due to its frequency switching. On the other hand, many household appliances also use inverter technology in their operation that may also generate the disturbance in the frequency range of 9-150 kHz even when it is connected to the clean supply provided by the utility grid. Since the power supplied by PV-rooftop system may contain disturbance, it is important to explore the effect of PV-rooftop system to the disturbance generated by household appliances. The study investigates the disturbance profile due to the interaction between the disturbance generated by PV-rooftop system and the disturbance generated by the household appliances. The devices under test are PV-Rooftop system as the power supply and the induction cooker, inverter-based microwave, vacuum cleaner, CFL and LED lamp as the household appliances. The results of the measurement show that the PV-rooftop generates disturbance at frequency 16 kHz when operated individually. The disturbance generated by PV-rooftop system is generally reduced when the household appliance is connected. The disturbance reduction has different trend. Some appliances including induction cooker and inverter-based microwave reduce the disturbance significantly due to their low internal impedance at the frequency of 16 kHz that may filter the disturbance of PV-rooftop system.","PeriodicalId":54929,"journal":{"name":"International Review of Electrical Engineering-Iree","volume":"23 2 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Disturbance Profiles of Household Appliances on Photovoltaic System in Frequency Range of 9-150 kHz\",\"authors\":\"B. Sudiarto, F. Faizal, F. Husnayain, H. Hirsch\",\"doi\":\"10.15866/iree.v16i5.20275\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, the renewable energy power generation has been widely used in residential customer by installing PV-rooftop on grid system. The PV-rooftop system uses inverter, which may generate the disturbance in the frequency range of 9-150 kHz due to its frequency switching. On the other hand, many household appliances also use inverter technology in their operation that may also generate the disturbance in the frequency range of 9-150 kHz even when it is connected to the clean supply provided by the utility grid. Since the power supplied by PV-rooftop system may contain disturbance, it is important to explore the effect of PV-rooftop system to the disturbance generated by household appliances. The study investigates the disturbance profile due to the interaction between the disturbance generated by PV-rooftop system and the disturbance generated by the household appliances. The devices under test are PV-Rooftop system as the power supply and the induction cooker, inverter-based microwave, vacuum cleaner, CFL and LED lamp as the household appliances. The results of the measurement show that the PV-rooftop generates disturbance at frequency 16 kHz when operated individually. The disturbance generated by PV-rooftop system is generally reduced when the household appliance is connected. The disturbance reduction has different trend. Some appliances including induction cooker and inverter-based microwave reduce the disturbance significantly due to their low internal impedance at the frequency of 16 kHz that may filter the disturbance of PV-rooftop system.\",\"PeriodicalId\":54929,\"journal\":{\"name\":\"International Review of Electrical Engineering-Iree\",\"volume\":\"23 2 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Review of Electrical Engineering-Iree\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15866/iree.v16i5.20275\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Mathematics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Review of Electrical Engineering-Iree","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15866/iree.v16i5.20275","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 2

摘要

近年来,通过安装光伏屋顶并网系统,可再生能源发电已广泛应用于住宅用户。光伏屋顶系统采用逆变器,由于逆变器的频率切换,可能会在9- 150khz的频率范围内产生干扰。另一方面,许多家用电器在运行中也使用逆变器技术,即使连接到公用电网提供的清洁电源,也可能在9-150 kHz的频率范围内产生干扰。由于光伏-屋顶系统提供的电力可能含有扰动,因此探讨光伏-屋顶系统对家用电器产生的扰动的影响具有重要意义。研究了光伏屋顶系统产生的扰动与家用电器产生的扰动相互作用所产生的扰动分布。测试设备为光伏屋顶系统作为电源,家用电器为电磁炉、逆变器微波、吸尘器、节能灯和LED灯。测量结果表明,单独工作时,光伏屋顶在16 kHz频率处产生扰动。当家用电器接入后,光伏-屋顶系统产生的干扰通常会减少。扰动减少有不同的趋势。一些电器,包括电磁炉和基于逆变器的微波炉,由于其在16 kHz频率下的低内部阻抗可以过滤光伏屋顶系统的干扰,因此可以显著减少干扰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Disturbance Profiles of Household Appliances on Photovoltaic System in Frequency Range of 9-150 kHz
Recently, the renewable energy power generation has been widely used in residential customer by installing PV-rooftop on grid system. The PV-rooftop system uses inverter, which may generate the disturbance in the frequency range of 9-150 kHz due to its frequency switching. On the other hand, many household appliances also use inverter technology in their operation that may also generate the disturbance in the frequency range of 9-150 kHz even when it is connected to the clean supply provided by the utility grid. Since the power supplied by PV-rooftop system may contain disturbance, it is important to explore the effect of PV-rooftop system to the disturbance generated by household appliances. The study investigates the disturbance profile due to the interaction between the disturbance generated by PV-rooftop system and the disturbance generated by the household appliances. The devices under test are PV-Rooftop system as the power supply and the induction cooker, inverter-based microwave, vacuum cleaner, CFL and LED lamp as the household appliances. The results of the measurement show that the PV-rooftop generates disturbance at frequency 16 kHz when operated individually. The disturbance generated by PV-rooftop system is generally reduced when the household appliance is connected. The disturbance reduction has different trend. Some appliances including induction cooker and inverter-based microwave reduce the disturbance significantly due to their low internal impedance at the frequency of 16 kHz that may filter the disturbance of PV-rooftop system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Review of Electrical Engineering-Iree
International Review of Electrical Engineering-Iree 工程技术-工程:电子与电气
CiteScore
3.30
自引率
0.00%
发文量
31
审稿时长
4 months
期刊介绍: The International Review of Electrical Engineering (IREE) is a peer-reviewed journal that publishes original theoretical and applied papers on all aspects of electrical engineering. The topics to be covered include, but are not limited to: instrumentations and measurements, power devices, energy conversion, mathematical modelling, electrical machines, power electronics and its applications (power electronics applications for home, aerospace, automotive, lighting systems and so on), signal processing, diagnostics, reliability, dependability safety and electromagnetic compatibility, power generation, transmission, and distribution, power system planning and control, network harmonics, power quality, optimization techniques, fault location and analysis, distributed generation, co-generation, renewable energy sources, energy management systems, applications of expert systems, electric and hybrid vehicles, vehicular technology, magnetic fields, theory and modelling of magnetic materials, nanotechnology, plasma engineering, quantum brownian motors, sensors and actuators, electrical circuits, teaching and continuous education, related topics. IREE also publishes letters to the Editor and research notes which discuss new research, or research in progress in any of the above thematic areas.
期刊最新文献
Design and Analysis of a Novel Multi-Level Inverter Topology Using DC Sources Solutions to Improve Transient Stability of Universal Grid-Forming Inverter-Based Resources Voltage Event Classification Method Based on Symmetrical Components Models for Extended ABC Classification Criterion A Fault Diagnostic Protection Scheme Technique for a Grid-Integrated Power Distribution System Application of an Integrated Analytic Hierarchy Process and Interpretive Structural Modeling Methodology for Selecting Energy-Saving Methods
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1