坦桑尼亚海洋路癌症研究所儿童Wilm肿瘤患者二束和六束适形放疗方案的剂量学比较

R. M. Mruma, N. Dharsee, Christina V Malichewe, J. D. Kisukari, Geofrey F. Soko, Hemed S. Myanza, Furahini Yoram
{"title":"坦桑尼亚海洋路癌症研究所儿童Wilm肿瘤患者二束和六束适形放疗方案的剂量学比较","authors":"R. M. Mruma, N. Dharsee, Christina V Malichewe, J. D. Kisukari, Geofrey F. Soko, Hemed S. Myanza, Furahini Yoram","doi":"10.4314/tjs.v49i1.10","DOIUrl":null,"url":null,"abstract":"This study aimed to compare the dose distributions of three-dimensional conformal treatment planning using two and six radiation beams among paediatric patients receiving radiotherapy for Wilms tumour at Ocean Road Cancer Institute. CT scans of 53 patients were used to generate 106 treatment plans, 53 plans for two beams, and 53 plans for six beams. Planning target volumes and organs at risk parameters were compared between both plans using paired samples t-test.  A p-value < 0.05 was considered statistically significant. The findings showed that the D95% and Dmean of the target are better with six beams than with the two-beam plans (p ˂ 0.001). The conformity index and monitor unit are significantly better with two-beam plans than with six-beam plans (p ˂ 0.001). No volume of the contralateral kidney received more than 12 Gy for both two and six plans. There were no differences in Dmax for the spinal cord (p = 0.208), while Dmean was observed to be lower in two compared to six beams (p ˂ 0.001) for the liver. Six beam plans have good target coverage, while two beam plans have good conformity index and monitor unit. The observed doses to the organs at risk in both plans were lower than their normal tolerance. \nKeywords:    Wilm's tumour, Three-dimensional conformal radiotherapy, whole abdomen radiotherapy, paediatric radiotherapy, Dosimetry","PeriodicalId":22207,"journal":{"name":"Tanzania Journal of Science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dosimetric Comparison Between Two and Six Beams Conformal Radiotherapy Plans for Paediatric Wilm's Tumour Patients at Ocean Road Cancer Institute, Tanzania\",\"authors\":\"R. M. Mruma, N. Dharsee, Christina V Malichewe, J. D. Kisukari, Geofrey F. Soko, Hemed S. Myanza, Furahini Yoram\",\"doi\":\"10.4314/tjs.v49i1.10\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study aimed to compare the dose distributions of three-dimensional conformal treatment planning using two and six radiation beams among paediatric patients receiving radiotherapy for Wilms tumour at Ocean Road Cancer Institute. CT scans of 53 patients were used to generate 106 treatment plans, 53 plans for two beams, and 53 plans for six beams. Planning target volumes and organs at risk parameters were compared between both plans using paired samples t-test.  A p-value < 0.05 was considered statistically significant. The findings showed that the D95% and Dmean of the target are better with six beams than with the two-beam plans (p ˂ 0.001). The conformity index and monitor unit are significantly better with two-beam plans than with six-beam plans (p ˂ 0.001). No volume of the contralateral kidney received more than 12 Gy for both two and six plans. There were no differences in Dmax for the spinal cord (p = 0.208), while Dmean was observed to be lower in two compared to six beams (p ˂ 0.001) for the liver. Six beam plans have good target coverage, while two beam plans have good conformity index and monitor unit. The observed doses to the organs at risk in both plans were lower than their normal tolerance. \\nKeywords:    Wilm's tumour, Three-dimensional conformal radiotherapy, whole abdomen radiotherapy, paediatric radiotherapy, Dosimetry\",\"PeriodicalId\":22207,\"journal\":{\"name\":\"Tanzania Journal of Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tanzania Journal of Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4314/tjs.v49i1.10\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tanzania Journal of Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/tjs.v49i1.10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在比较两束和六束放射治疗计划在海洋路癌症研究所接受Wilms肿瘤放射治疗的儿科患者中的剂量分布。53例患者的CT扫描产生106个治疗方案,其中53个为两束治疗方案,53个为六束治疗方案。采用配对样本t检验比较两种方案的计划靶体积和危险器官参数。p值< 0.05认为有统计学意义。结果表明,六光束方案的D95%和Dmean优于两光束方案(p小于0.001)。两梁方案的符合性指数和监测单元明显优于六梁方案(p小于0.001)。两组和六组对侧肾脏均未接受超过12 Gy的剂量。脊髓的Dmax没有差异(p = 0.208),而肝脏的Dmean在两束中比在六束中低(p小于0.001)。6种波束方案具有较好的目标覆盖率,2种波束方案具有较好的一致性指标和监测单元。在两个计划中,观察到的危及器官的剂量都低于正常的耐受性。关键词:Wilm肿瘤,三维适形放疗,全腹放疗,儿科放疗,剂量学
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dosimetric Comparison Between Two and Six Beams Conformal Radiotherapy Plans for Paediatric Wilm's Tumour Patients at Ocean Road Cancer Institute, Tanzania
This study aimed to compare the dose distributions of three-dimensional conformal treatment planning using two and six radiation beams among paediatric patients receiving radiotherapy for Wilms tumour at Ocean Road Cancer Institute. CT scans of 53 patients were used to generate 106 treatment plans, 53 plans for two beams, and 53 plans for six beams. Planning target volumes and organs at risk parameters were compared between both plans using paired samples t-test.  A p-value < 0.05 was considered statistically significant. The findings showed that the D95% and Dmean of the target are better with six beams than with the two-beam plans (p ˂ 0.001). The conformity index and monitor unit are significantly better with two-beam plans than with six-beam plans (p ˂ 0.001). No volume of the contralateral kidney received more than 12 Gy for both two and six plans. There were no differences in Dmax for the spinal cord (p = 0.208), while Dmean was observed to be lower in two compared to six beams (p ˂ 0.001) for the liver. Six beam plans have good target coverage, while two beam plans have good conformity index and monitor unit. The observed doses to the organs at risk in both plans were lower than their normal tolerance. Keywords:    Wilm's tumour, Three-dimensional conformal radiotherapy, whole abdomen radiotherapy, paediatric radiotherapy, Dosimetry
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modeling the Transmission Dynamics of Tuberculosis in Humans Digitisation of Classical Exercise Practices with STACK: Management of Large Mathematics Classes in Higher Education Institutions Scientific Landscape on Phthalates Biodegradation Research: A Bibliometric and Scientometric Study Activated Carbon Based on Borassus aethiopum Shells, Hulls, Kernels and Fruits for Removal of Phenol and 2-Chlorophenol from Water Impact of Zn and W Doping Levels on Properties of Thermochromic VO2-Based Thin Films
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1